Impact on Clinical Outcome of Premature Interruption of Cryoenergy Delivery Due to Phrenic Nerve Palsy During Second Generation Cryoballoon Ablation for Paroxysmal Atrial Fibrillation

被引:8
作者
Chierchia, Gian-Battista [1 ]
Mugnai, Giacomo [1 ]
Hunuk, Burak [1 ]
Stroker, Erwin [1 ]
Velagic, Vedran [1 ]
Saitoh, Yukio [1 ]
Irfan, Ghazala [1 ]
Hacioglu, Ebru [1 ]
Ciconte, Giuseppe [1 ]
Brugada, Pedro [1 ]
De Asmundis, Carlo [1 ]
机构
[1] UZ Brussel VUB, Heart Rhythm Management Ctr, B-1090 Brussels, Belgium
关键词
atrial fibrillation; catheter ablation; cryoablation; cryoballoon; phrenic nerve palsy; PULMONARY VEIN ISOLATION; CRYOABLATION; BALLOON; RADIOFREQUENCY; DEFLATION; CATHETER; EFFICACY; INJURY; 1ST;
D O I
10.1111/jce.12718
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cryoenergy Interruption Due to Phrenic Nerve Palsy IntroductionRight phrenic nerve paralysis (PNP) is the most frequently observed complication occurring during cryoballoon ablation (CB). Our aim was to analyze the impact of the premature interruption (PI) of cryoenergy delivery in a large series of consecutive patients during ablation in the right-sided veins on clinical outcome. Methods and ResultsAll consecutive patients having undergone second-generation CB ablation for paroxysmal atrial fibrillation (AF) from July 2012 to September 2014 were included in our analysis. Exclusion criteria were persistent AF, presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease, left atrium (LA) diameter 55 mm, and contraindications to general anesthesia. A total 287 consecutive patients with drug-resistant paroxysmal AF having undergone pulmonary vein isolation by means of CB technology (male 65%, age 57.6 13.1 years) were included. The incidence of PNP in the study population was 8.0% (23/287). At a mean follow-up of 11.5 +/- 3.9 months, the success rate without antiarrhythmic therapy was 81.6%. Patients with PNP had similar rates of AF recurrence compared with those without PNP (17.4% vs. 17.8%; P = 0.9); the former had a mean follow-up of 10.9 +/- 3.7 months, the latter 11.8 +/- 4.5 months (P = 0.3). ConclusionConclusion: Our findings show that patients in whom freezing was interrupted due to PNP had a similar outcome on 1-year follow-up compared with those in whom freezing cycles were completed in the septal veins. No baseline clinical or procedural characteristics were found to predict AF recurrence in patients having experienced PNP.
引用
收藏
页码:950 / 955
页数:6
相关论文
共 21 条
[1]   Pulmonary Vein Isolation Using a Second-Generation Cryoballoon Catheter: A Randomized Comparison of Ablation Duration and Method of Deflation [J].
Andrade, Jason G. ;
Dubuc, Marc ;
Guerra, Peter G. ;
Landry, Evelyn ;
Coulombe, Nicolas ;
Leduc, Hugues ;
Rivard, Lena ;
Macle, Laurent ;
Thibault, Bernard ;
Talajic, Mario ;
Roy, Denis ;
Khairy, Paul .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (06) :692-698
[2]  
Andrade Jason G, 2012, Indian Pacing Electrophysiol J, V12, P39
[3]   Efficacy and safety of cryoballoon ablation for atrial fibrillation: A systematic review of published studies [J].
Andrade, Jason G. ;
Khairy, Paul ;
Guerra, Peter G. ;
Deyell, Marc W. ;
Rivard, Lena ;
Macle, Laurent ;
Thibault, Bernard ;
Talajic, Mario ;
Roy, Denis ;
Dubuc, Marc .
HEART RHYTHM, 2011, 8 (09) :1444-1451
[4]   Imaging before cryoablation of atrial fibrillation: is phrenic nerve palsy predictable? [J].
Canpolat, Ugur ;
Aytemir, Kudret ;
Hizal, Mustafa ;
Hazirolan, Tuncay ;
Yorgun, Hikmet ;
Sahiner, Levent ;
Kaya, Ergun Baris ;
Oto, Ali .
EUROPACE, 2014, 16 (04) :505-510
[5]   Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: A comparison between the first- and second-generation balloon [J].
Casado-Arroyo, Ruben ;
Chierchia, Gian-Battista ;
Conte, Giulio ;
Levinstein, Moises ;
Sieira, Juan ;
Rodriguez-Manero, Moises ;
di Giovanni, Giacomo ;
Baltogiannis, Yannis ;
Wauters, Kristel ;
de Asmundis, Carlo ;
Sarkozy, Andrea ;
Brugada, Pedro .
HEART RHYTHM, 2013, 10 (09) :1318-1324
[6]   Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: a comparison between radiofrequency catheter ablation and second-generation cryoballoon ablation [J].
Ciconte, Giuseppe ;
Baltogiannis, Giannis ;
de Asmundis, Carlo ;
Sieira, Juan ;
Conte, Giulio ;
Di Giovanni, Giacomo ;
Saitoh, Yukio ;
Irfan, Ghazala ;
Mugnai, Giacomo ;
Hunuk, Burak ;
Chierchia, Gian-Battista ;
Brugada, Pedro .
EUROPACE, 2015, 17 (04) :559-565
[7]   Improved In Vivo Performance of Second-Generation Cryoballoon for Pulmonary Vein Isolation [J].
Coulombe, Nicolas ;
Paulin, Jaime ;
Su, Wilber .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (08) :919-925
[8]   One-Year Follow-Up After Single Procedure Cryoballoon Ablation: A Comparison Between the First and Second Generation Balloon [J].
Di Giovanni, Giacomo ;
Wauters, Kristel ;
Chierchia, Gian-Battista ;
Sieira, Juan ;
Levinstein, Moises ;
Conte, Giulio ;
De Asmundis, Carlo ;
Baltogiannis, Giannis ;
Saitoh, Yukio ;
Ciconte, Giuseppe ;
Julia, Justo ;
Mugnai, Giacomo ;
Irfan, Ghazala ;
Brugada, Pedro .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (08) :834-839
[9]   Diaphragmatic electromyography during cryoballoon ablation: a novel concept in the prevention of phrenic nerve palsy [J].
Franceschi, Frederic ;
Dubuc, Marc ;
Guerra, Peter G. ;
Delisle, Stephane ;
Romeo, Philippe ;
Landry, Evelyn ;
Koutbi, Linda ;
Rivard, Lena ;
Macle, Laurent ;
Thibault, Bernard ;
Talajic, Mario ;
Roy, Denis ;
Khairy, Paul .
HEART RHYTHM, 2011, 8 (06) :885-891
[10]   Incidence and characteristics of phrenic nerve palsy following pulmonary vein isolation with the second-generation as compared with the first-generation cryoballoon in 360 consecutive patients [J].
Fuernkranz, Alexander ;
Bordignon, Stefano ;
Schmidt, Boris ;
Perrotta, Laura ;
Dugo, Daniela ;
De lazzari, Manuel ;
Schulte-Hahn, Britta ;
Nowak, Bernd ;
Chun, Julian K. R. .
EUROPACE, 2015, 17 (04) :574-578