Voltammetric determination of ascorbic acid in the presence of acetaminophen and tryptophan using an improved carbon nanotube paste electrode

被引:17
作者
Beitollahi, Hadi [1 ]
Mohammadi, Somayeh [2 ]
机构
[1] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Dept Environm, Kerman, Iran
[2] Payame Noor Univ, Dept Chem, Tehran 193954697, Iran
关键词
Ascorbic acid; Acetaminophen; Tryptophan; Carbon nanotube paste electrode; Electrocatalysis; FOLIC-ACID; URIC-ACID; SELECTIVE DETERMINATION; 2,7-BIS(FERROCENYL ETHYL)FLUOREN-9-ONE; ELECTROCATALYTIC OXIDATION; IONIC LIQUID; SENSOR; NOREPINEPHRINE; EPINEPHRINE; FABRICATION;
D O I
10.1016/S1872-2067(12)60544-0
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A carbon paste electrode (CPE) modified with carbon nanotubes and 5-amino-3',4'-dimethyl- bi-phenyl-2-ol (5ADB) is prepared. Under the optimum pH of 7.0, the oxidation of ascorbic acid (AA) on the modified CPE occurs at a potential about 280 mV less positive than that on the unmodified CPE. Some kinetic and thermodynamic parameters for electrocatalytic oxidation of AA, including electron transfer coefficient (alpha = 0.58) and diffusion coefficient (D = 2.2 x 10(-6) cm(2)/s), are also determined. AA, acetaminophen (AC), and tryptophan (TRP) were detected simultaneously using the modified CPE. The peak potentials recorded using the modified CPE in phosphate-buffered solution at pH 7.0 were 265, 465, and 780 mV for AA, AC, and TRP, respectively. The modified CPE was successfully used to determine the concentrations of AA, AC, and TRP in real samples. (c) 2013, Dalian Institute of Chemical Physics, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1098 / 1104
页数:7
相关论文
共 48 条
[1]   Fabrication of a sensor for simultaneous determination of norepinephrine, acetaminophen and tryptophan using a modified carbon nanotube paste electrode [J].
Akhgar, Mohammad Reza ;
Beitollahi, Hadi ;
Salari, Mohammad ;
Karimi-Maleh, Hassan ;
Zamani, Hassan .
ANALYTICAL METHODS, 2012, 4 (01) :259-264
[2]   Selective determination of ascorbic acid with a novel hybrid material based 1-butyl-3-methylimidazolium tetrafluoroborate ionic liquid and the Dawson type ion [P2Mo18O62]6- immobilized on glassy carbon [J].
Ammam, Malika ;
Easton, E. Bradley .
ELECTROCHIMICA ACTA, 2011, 56 (07) :2847-2855
[3]  
Anker A, 2001, CLIN TOXICOLOGY
[4]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[5]   Ascorbic acid: much more than just an antioxidant [J].
Arrigoni, O ;
De Tullio, MC .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2002, 1569 (1-3) :1-9
[6]   Electrochemical behavior of a carbon paste electrode modified with 5-amino-3′,4′-dimethyl-biphenyl-2-ol/carbon nanotube and its application for simultaneous determination of isoproterenol, acetaminophen and N-acetylcysteine [J].
Beitollahi, Hadi ;
Mohadesi, Alireza ;
Mohammadi, Somayeh ;
Akbari, Ali .
ELECTROCHIMICA ACTA, 2012, 68 :220-226
[7]   Electrocatalytic and simultaneous determination of isoproterenol, uric acid and folic acid at molybdenum (VI) complex-carbon nanotube paste electrode [J].
Beitollahi, Hadi ;
Sheikhshoaie, Iran .
ELECTROCHIMICA ACTA, 2011, 56 (27) :10259-10263
[8]   Selective voltammetric determination of norepinephrine in the presence of acetaminophen and folic acid at a modified carbon nanotube paste electrode [J].
Beitollahi, Hadi ;
Sheikhshoaie, Iran .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 661 (02) :336-342
[9]   Fabrication of a nanostructure-based electrochemical sensor for simultaneous determination of N-acetylcysteine and acetaminophen [J].
Beitollahi, Hadi ;
Raoof, Jahan-Bakhsh ;
Hosseinzadeh, Rahman .
TALANTA, 2011, 85 (04) :2128-2134
[10]   Application of a Carbon-Paste Electrode Modified with 2,7-Bis(ferrocenyl ethyl)fluoren-9-one and Carbon Nanotubes for Voltammetric Determination of Levodopa in the Presence of Uric Acid and Folic Acid [J].
Beitollahi, Hadi ;
Raoof, Jahan-Bakhsh ;
Hosseinzadeh, Rahman .
ELECTROANALYSIS, 2011, 23 (08) :1934-1940