Prospects and challenges of rendering tissue density in Hounsfield units for cone beam computed tomography

被引:105
作者
Molteni, Roberto
机构
[1] Arlington Heights, IL 60004
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2013年 / 116卷 / 01期
关键词
METAL ARTIFACT REDUCTION; BONE-DENSITY; SCATTER ESTIMATION; IMPLANT SITES; VOXEL VALUES; GREY LEVELS; CT; QUALITY; MULTISLICE; CONVERSION;
D O I
10.1016/j.oooo.2013.04.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Limitations in rendering of tissue density in Hounsfield units (HUs) for cone beam computed tomography (CBCT) are described and illustrated using a phantom and two CBCT systems to demonstrate grayscale measurement variability. Materials and methods. The basis of the HU scale, its correlation with measured computed tomography (CT) numbers, and the limitations in the accuracy of such correlation due to artifacts are discussed. Rendering of tissue densities based on HU values of two CBCT systems [NewTom VGi and Hyperion X9, respectively large and small field of view (FOV)] are measured using a phantom. Results. Data produced from small FOV CBCT acquisition are generally less affected by artifacts compared with large FOV CBCT. Conclusions. Artifacts challenge the accurate conversion of density values into HUs. Care should be taken when interpreting quantitative density measurements obtained with CBCT. With more advanced software and methods, it may be possible to improve the consistency and accuracy of density measurements.
引用
收藏
页码:105 / 119
页数:15
相关论文
共 47 条
  • [1] Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging
    Abdoli, Mehrsima
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3343 - 3360
  • [2] Fuster-Torres MA, 2011, INT J ORAL MAX IMPL, V26, P1051
  • [3] [Anonymous], X-ray mass attenuation coefficients
  • [4] [Anonymous], GAMM GEN CAT RAD ONC, P148
  • [5] Artifacts in CT: Recognition and avoidance
    Barrett, JF
    Keat, N
    [J]. RADIOGRAPHICS, 2004, 24 (06) : 1679 - 1691
  • [6] Evaluation of a cone beam CT artefact reduction algorithm
    Bechara, B.
    McMahan, C. A.
    Geha, H.
    Noujeim, M.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (05) : 422 - 428
  • [7] Metal artefact reduction with cone beam CT: an in vitro study
    Bechara, B. B.
    Moore, W. S.
    McMahan, C. A.
    Noujeim, M.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (03) : 248 - 253
  • [8] Diagnostic x-ray spectra: A comparison of spectra generated by different computational methods with a measured spectrum
    Bhat, M
    Pattison, J
    Bibbo, G
    Caon, M
    [J]. MEDICAL PHYSICS, 1998, 25 (01) : 114 - 120
  • [9] Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system
    Bryant, J. A.
    Drage, N. A.
    Richmond, S.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (07) : 365 - 374
  • [10] Is it time to set a Hounsfield standard?
    Bryant, J. A.
    Drage, N. A.
    Richmond, S.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (05) : 306 - 306