The single photon sensitivity of the Adaptive Gain Integrating Pixel Detector

被引:20
作者
Becker, Julian [1 ]
Greiffenberg, Dominic [2 ]
Trunk, Ulrich [1 ]
Shi, Xintian [2 ]
Dinapoli, Roberto [2 ]
Mozzanica, Aldo [2 ]
Henrich, Beat [2 ]
Schmitt, Bernd [2 ]
Graafsma, Heinz [1 ]
机构
[1] DESY, D-22607 Hamburg, Germany
[2] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
关键词
AGIPD; Simulation; European XFEL; Noise performance; AGIPD DETECTOR; PERFORMANCE;
D O I
10.1016/j.nima.2012.08.008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Single photon sensitivity is an important property of certain detection systems. This work investigated the single photon sensitivity of the Adaptive Gain Integrating Pixel Detector (AGIPD) and its dependence on possible detector noise values. Due to special requirements at the European X-ray Free Electron Laser (XFEL) the AGIPD finds the number of photons absorbed in each pixel by integrating the total signal. Photon counting is done off line on a thresholded data set. It was shown that AGIPD will be sensitive to single photons of 8 key energy or more (detection efficiency >> 50%, less than 1 count due to noise per 10(6) pixels). Should the final noise be at the lower end of the possible range (200-400 electrons) single photon sensitivity can also be achieved at 5 key beam energy. It was shown that charge summing schemes are beneficial when the noise is sufficiently low. The total detection rate of events is increased and the probability to count a single event multiple times in adjacent pixels is reduced by a factor of up to 40. The entry window of AGIPD allows 3 key photons to reach the sensitive volume with approximately 70% probability. Therefore the low energy performance of AGIPD was explored, finding a maximum noise floor below 0.035 hits/pixel/frame at 3 keV beam energy. Depending on the noise level and selected threshold this value can be reduced by a factor of approximately 10. Even though single photon sensitivity, as defined in this work, is not given, imaging at this energy is still possible, allowing Poisson noise limited performance for signals significantly above the noise floor. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 90
页数:9
相关论文
共 21 条
[1]  
Altarelli M., 2006, The European X-Ray Free-Electron Laser Technical Design Report
[2]   The medipix3 prototype, a pixel readout chip working in single photon counting mode with improved spectrometric performance [J].
Ballabriga, R. ;
Campbell, M. ;
Heijne, E. H. M. ;
Llopart, X. ;
Tlustos, L. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) :1824-1829
[3]   Advantages of a logarithmic sampling scheme for XPCS experiments at the European XFEL using the AGIPD detector [J].
Becker, J. ;
Graafsma, H. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[4]   Simulation study of the impact of AGIPD design choices on X-ray Photon Correlation Spectroscopy utilizing the intensity autocorrelation technique [J].
Becker, J. ;
Gutt, C. ;
Graafsma, H. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[6]   The AGIPD detector for the European XFEL [J].
Greiffenberg, D. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[7]  
Greiffenberg D., 2012, WE F P 01 11 INT C S, V10
[8]   The adaptive gain integrating pixel detector AGIPD a detector for the European XFEL [J].
Henrich, B. ;
Becker, J. ;
Dinapoli, R. ;
Goettlicher, P. ;
Graafsma, H. ;
Hirsemann, H. ;
Klanner, R. ;
Krueger, H. ;
Mazzocco, R. ;
Mozzanica, A. ;
Perrey, H. ;
Potdevin, G. ;
Schmitt, B. ;
Shi, X. ;
Srivastava, A. K. ;
Trunk, U. ;
Youngman, C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 :S11-S14
[9]  
Madsen A., 2011, TR2011008
[10]  
Mancuso A., 2011, TR2011007, DOI DOI 10.3204/XFELEU/TR-2011-007