Cone Beam Computed Tomography Image Guidance System for a Dedicated Intracranial Radiosurgery Treatment Unit

被引:25
作者
Ruschin, Mark [1 ,2 ]
Komljenovic, Philip T. [1 ]
Ansell, Steve [1 ]
Menard, Cynthia [1 ,2 ]
Bootsma, Gregory [3 ]
Cho, Young-Bin [1 ,2 ]
Chung, Caroline [1 ,2 ]
Jaffray, David [1 ,2 ]
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[3] Univ Toronto, Dept Med Biophys, Toronto, ON M5S 1A1, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2013年 / 85卷 / 01期
关键词
BRAIN RADIATION-THERAPY; GAMMA-KNIFE PERFEXION; STEREOTACTIC RADIOSURGERY; METASTASES; FRAME; UNCERTAINTIES; RADIOTHERAPY; HEAD; CT;
D O I
10.1016/j.ijrobp.2012.03.022
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Image guidance has improved the precision of fractionated radiation treatment delivery on linear accelerators. Precise radiation delivery is particularly critical when high doses are delivered to complex shapes with steep dose gradients near critical structures, as is the case for intracranial radiosurgery. To reduce potential geometric uncertainties, a cone beam computed tomography (CT) image guidance system was developed in-house to generate high-resolution images of the head at the time of treatment, using a dedicated radiosurgery unit. The performance and initial clinical use of this imaging system are described. Methods and Materials: A kilovoltage cone beam CT system was integrated with a Leksell Gamma Knife Perfexion radiosurgery unit. The X-ray tube and flat-panel detector are mounted on a translational arm, which is parked above the treatment unit when not in use. Upon descent, a rotational axis provides 210 degrees of rotation for cone beam CT scans. Mechanical integrity of the system was evaluated over a 6-month period. Subsequent clinical commissioning included end-to-end testing of targeting performance and subjective image quality performance in phantoms. The system has been used to image 2 patients, 1 of whom received single-fraction radiosurgery and 1 who received 3 fractions, using a relocatable head frame. Results: Images of phantoms demonstrated soft tissue contrast visibility and submillimeter spatial resolution. A contrast difference of 35 HU was easily detected at a calibration dose of 1.2 cGy (center of head phantom). The shape of the mechanical flex vs scan angle was highly reproducible and exhibited <0.2 mm peak-to-peak variation. With a 0.5-mm voxel pitch, the maximum targeting error was 0.4 mm. Images of 2 patients were analyzed offline and submillimeter agreement was confirmed with conventional frame. Conclusions: A cone beam CT image guidance system was successfully adapted to a radiosurgery unit. The system is capable of producing high-resolution images of bone and soft tissue. The system is in clinical use and provides excellent image guidance without invasive frames. (C) 2013 Elsevier Inc.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 20 条
[1]   Whole brain radiation therapy with or without stereotactic radiosurgery boost for patients with one to three brain metastases: phase III results of the RTOG 9508 randomised trial [J].
Andrews, DW ;
Scott, CB ;
Sperduto, PW ;
Flanders, AE ;
Gaspar, LE ;
Schell, MC ;
Werner-Wasik, M ;
Demas, W ;
Ryu, J ;
Bahary, JP ;
Souhami, L ;
Rotman, M ;
Mehta, MP ;
Curran, WJ .
LANCET, 2004, 363 (9422) :1665-1672
[2]   Stereotactic radiosurgery plus whole-brain radiation therapy vs stereotactic radiosurgery alone for treatment of brain metastases - A randomized controlled trial [J].
Aoyama, Hidefumi ;
Shirato, Hiroki ;
Tago, Masao ;
Nakagawa, Keiichi ;
Toyoda, Tatsuya ;
Hatano, Kazuo ;
Kenjyo, Masahiro ;
Oya, Natsuo ;
Hirota, Saeko ;
Shioura, Hiroki ;
Kunieda, Etsuo ;
Inomata, Taisuke ;
Hayakawa, Kazushige ;
Katoh, Norio ;
Kobashi, Gen .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (21) :2483-2491
[3]  
Arn T, 2012, COMMUNICATION
[4]   The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT [J].
Bootsma, G. J. ;
Verhaegen, F. ;
Jaffray, D. A. .
MEDICAL PHYSICS, 2011, 38 (02) :897-914
[5]   Neurocognition in patients with brain metastases treated with radiosurgery or radiosurgery plus whole-brain irradiation: a randomised controlled trial [J].
Chang, Eric L. ;
Wefel, Jeffrey S. ;
Hess, Kenneth R. ;
Allen, Pamela K. ;
Lang, Frederick F. ;
Kornguth, David G. ;
Arbuckle, Rebecca B. ;
Swint, J. Michael ;
Shiu, Almon S. ;
Maor, Moshe H. ;
Meyers, Christina A. .
LANCET ONCOLOGY, 2009, 10 (11) :1037-1044
[6]   Evaluating Stress-related Uncertainties in Stereotactic Frame-based Localization for Gamma Knife Radiosurgery [J].
Cho, Y. ;
Bootsma, G. ;
Ruschin, M. ;
MacFadden, D. ;
Hodaie, M. ;
Menard, C. ;
Jaffray, D. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03) :S691-S692
[7]   Accurate technique for complete geometric calibration of cone-beam computed tomography systems [J].
Cho, YB ;
Moseley, DJ ;
Siewerdsen, JH ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (04) :968-983
[8]   Characterization of image quality and image-guidance performance of a preclinical microirradiator [J].
Clarkson, R. ;
Lindsay, P. E. ;
Ansell, S. ;
Wilson, G. ;
Jelveh, S. ;
Hill, R. P. ;
Jaffray, D. A. .
MEDICAL PHYSICS, 2011, 38 (02) :845-856
[9]   Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype [J].
Daly, M. J. ;
Siewerdsen, J. H. ;
Moseley, D. J. ;
Jaffray, D. A. ;
Irish, J. C. .
MEDICAL PHYSICS, 2006, 33 (10) :3767-3780
[10]   Fractionated (split dose) radiosurgery in patients with recurrent brain metastases: implications for survival [J].
Davey, P. ;
Schwartz, M. L. ;
Scora, D. ;
Gardner, S. ;
O'Brien, P. F. .
BRITISH JOURNAL OF NEUROSURGERY, 2007, 21 (05) :491-495