Layer-By-Layer (Chitosan/Polystyrene Sulfonate) Membrane-Based Fabry-Perot Interferometric Fiber Optic Biosensor

被引:23
作者
Chen, Li Han [1 ]
Ang, Xiu Min [1 ]
Chan, Chi Chiu [1 ]
Shaillender, Mutukumaraswamy [2 ]
Neu, Bjoern [1 ]
Wong, Wei Chang [1 ]
Zu, Peng [1 ]
Leong, Kam Chew [3 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Div Bioengn, Singapore 637457, Singapore
[2] Nanyang Technol Univ, Sch Mat Sci & Engn, Mat Technol Div, Singapore 637457, Singapore
[3] GLOBALFOUNDRIES Singapore Pte Ltd, Singapore 738406, Singapore
关键词
Biosensor; chitosan (CS); fiber-optic sensors; Fabry-Perot interferometer (FPI); layer-by-layer (LBL); MULTILAYER FILMS; POLYELECTROLYTE; BUILDUP;
D O I
10.1109/JSTQE.2012.2185221
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A label-free, layer-by-layer (LBL) modified, fiber-optic interferometry biosensor for real-time affinity-based protein sensing applications has been proposed. The proposed sensor allows real-time protein adsorption detection by monitoring interference wavelength shifts, which offers better dynamic range and stability in comparison to current detection of changes in optical intensity. With a label-free sensing mechanism, it eliminates issues of progressive leaching of indicators, expensive and time-consuming labeling procedures and undesirable nonspecific interactions with target proteins. The unique Fabry-Perot cavity consists of an LBL coating layer of nanometre thickness deposited on the distal ends of a hollow core cavity spliced to a standard single-mode optical fiber (SMF). This novel configuration allows the LBL sensing element to be enclosed by similar mediums, on both sides of the LBL multilayer film coat, thus surrounded by identical properties such as the same refractive index that improves the sensitivity of the proposed sensor. Furthermore, the LBL coat consisting of chitosan and polysodium styrene sulfonate, commonly used in drug delivery and cell culture, indicates good biocompatibility for future in vivo biomedical applications such as immunosensing and DNA hybridization detections.
引用
收藏
页码:1457 / 1464
页数:8
相关论文
共 29 条
[1]  
[Anonymous], 1980, ANAL CHEM, V52, P2242
[2]   Transport studies of BSA, lysozyme and ovalbumin through chitosan/polystyrene sulfonate multilayer membrane [J].
Aravind, Usha K. ;
Mathew, Jissy ;
Aravindakumar, C. T. .
JOURNAL OF MEMBRANE SCIENCE, 2007, 299 (1-2) :146-155
[3]   Extrinsic optical-fiber ultrasound sensor using a thin polymer film as a low-finesse Fabry-Perot interferometer [J].
Beard, PC ;
Mills, TN .
APPLIED OPTICS, 1996, 35 (04) :663-675
[4]   Layer-by-layer biomolecular assemblies for enzyme sensors, immunosensing, and nano architectures [J].
Campàs, M ;
O'Sullivan, C .
ANALYTICAL LETTERS, 2003, 36 (12) :2551-2569
[5]   Assembly of alternating polyelectrolyte and protein multilayer films for immunosensing .2. [J].
Caruso, F ;
Niikura, K ;
Furlong, DN ;
Okahata, Y .
LANGMUIR, 1997, 13 (13) :3427-3433
[6]   High performance chitosan diaphragm-based fiber-optic acoustic sensor [J].
Chen, L. H. ;
Chan, C. C. ;
Yuan, W. ;
Goh, S. K. ;
Sun, J. .
SENSORS AND ACTUATORS A-PHYSICAL, 2010, 163 (01) :42-47
[7]  
Consales M., 2008, Journal of Sensors, DOI 10.1155/2008/936074
[8]   Immunosensors for diagnostic applications [J].
Cruz, HJ ;
Rosa, CC ;
Oliva, AG .
PARASITOLOGY RESEARCH, 2002, 88 (Suppl 1) :S4-S7
[9]   NOMENCLATURE FOR THE PRESENTATION OF RESULTS OF CHEMICAL-ANALYSIS [J].
CURRIE, LA ;
SVEHLA, G .
PURE AND APPLIED CHEMISTRY, 1994, 66 (03) :595-608
[10]  
Del Villar I, 2008, CURR ANAL CHEM, V4, P341