Analysis of Biological Fluids by Direct Combination of Solid Phase Extraction and Desorption Electrospray Ionization Mass Spectrometry

被引:47
作者
Denes, Julia [1 ]
Katona, Maria [1 ]
Hosszu, Adam [1 ]
Czuczy, Noemi [1 ]
Takats, Zoltan [1 ,2 ]
机构
[1] Semmelweis Univ, Cell Screen Appl Res Ctr, H-1085 Budapest, Hungary
[2] Univ Giessen, Inst Analyt, Giessen, Germany
关键词
PHARMACEUTICALS; EXPLOSIVES; MECHANISMS; CHEMISTRY; SURFACES; SAMPLES;
D O I
10.1021/ac8024812
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel, solid phase extraction (SPE)-based sample preparation method was developed for desorption electrospray ionization (DESI) mass spectrometry. Conventional SPE sample preparation was followed by a custom elution procedure. The eluate was evaporated, from the closing frit of the cartridge using a gas jet. Thus the analyte was concentrated on the surface of the hit, which is ideal for DESI analysis. Application of the above SPE protocol allowed the concentration of the analyte content of up to I L liquid sample into a 1 mm diameter circular spot. The sample preparation procedure can improve the overall sensitivity of the method by up to 6 orders of magnitude if the sample volume is sufficient. The device has been tested using aqueous solutions of Rhodamine 116; the limit of detection was comparable to the LOD of electrospray analysis. Methodology was tested for drug monitoring applications in human serum. Levels of Cyclosporine A were determined using a 0.1 mL serum sample. Dynamic range of the method exceeded 3 orders of magnitude; the detection limit was below the therapeutic serum concentration of the drug.
引用
收藏
页码:1669 / 1675
页数:7
相关论文
共 33 条
[1]   ENVIRONMENTAL APPLICATIONS OF MASS-SPECTROMETRY [J].
ALFORD, A .
BIOMEDICAL MASS SPECTROMETRY, 1978, 5 (04) :259-286
[2]   Desorption electrospray ionization mass spectrometry for high-throughput analysis of pharmaceutical samples in the ambient environment [J].
Chen, HW ;
Talaty, NN ;
Takáts, Z ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2005, 77 (21) :6915-6927
[3]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[4]   Ambient mass spectrometry [J].
Cooks, RG ;
Ouyang, Z ;
Takats, Z ;
Wiseman, JM .
SCIENCE, 2006, 311 (5767) :1566-1570
[5]   Simulation of atmospheric transport and droplet-thin film collisions in desorption electrospray ionization [J].
Costa, Anthony B. ;
Cooks, R. Graham .
CHEMICAL COMMUNICATIONS, 2007, (38) :3915-3917
[6]   Desorption electrospray ionization of explosives on surfaces:: Sensitivity and selectivity enhancement by reactive desorption electrospray ionization [J].
Cotte-Rodríguez, I ;
Takáts, Z ;
Talaty, N ;
Chen, HW ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2005, 77 (21) :6755-6764
[7]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[8]   Prevalence and detection of counterfeit pharmaceuticals: A mini review [J].
Fernandez, Facundo M. ;
Green, Michael D. ;
Newton, Paul N. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (03) :585-590
[9]   Simplifying capillary electrophoresis-mass spectrometry operation: Eliminating capillary derivatization by using self-coating background electrolytes [J].
Garza, Selynda ;
Chang, Silvia ;
Moini, Mehdi .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) :14-21
[10]   Recent developments in ambient ionization techniques for analytical mass spectrometry [J].
Harris, Glenn A. ;
Nyadong, Leonard ;
Fernandez, Facundo M. .
ANALYST, 2008, 133 (10) :1297-1301