Assessment of the Diurnal Blood Pressure Profile and Detection of Non-Dippers Based on Home or Ambulatory Monitoring

被引:41
作者
Stergiou, George S. [1 ]
Nasothimiou, Efthimia G. [1 ]
Destounis, Antonios [1 ]
Poulidakis, Emanouel [1 ]
Evagelou, Irini [1 ]
Tzamouranis, Dimitrios [1 ]
机构
[1] Third Univ, Hypertens Ctr, Dept Med, Sotiria Hosp, Athens, Greece
关键词
ambulatory blood pressure; asleep; blood pressure; home blood pressure; hypertension; nighttime; nocturnal; non-dippers; self-measurement; EUROPEAN-SOCIETY; SELF-MEASUREMENT; HYPERTENSION; REPRODUCIBILITY; DEVICE; SAMPLE;
D O I
10.1038/ajh.2012.82
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND A unique advantage of ambulatory blood pressure (ABP) monitoring is the assessment of nocturnal blood pressure (BP) and the detection of non-dippers. This study assessed nocturnal BP and non-dippers using a novel home BP (HBP) monitor. METHODS Eighty-one hypertensives performed within 2 weeks ABP (24-h, Microlife WatchBP O3) and HBP monitoring (Microlife WatchBPN) during daytime (6 days, duplicate morning and evening measurements) and nighttime (automated asleep measurements, 3 nights, 3 readings/night). Patients' preference in using ABP or HBP was assessed by a questionnaire. RESULTS Strong associations were found between ABP and HBP (intraclass correlation coefficients for awake systolic/diastolic 0.75/0.81; asleep 0.87/0.85). No statistically significant difference was found between HBP and ABP (mean difference +/- SD awake systolic/diastolic 1.5 +/- 10.1/-1.1 +/- 6.0 mm Hg, P = 0.20/0.09; asleep -0.4 +/- 7.8/-1.0 +/- 5.3, P = 0.63/0.09). There was substantial agreement (74%, kappa 0.2) between ABP and HBP in the detection of non-dippers, which was similar to the previously reported test-retest reproducibility of repeated ABP monitoring in the diagnosis of non-dippers. Moderate to severe disturbance from ABP monitoring was reported by 18% of the participants and severe restriction of their daily activities by 9, vs. 3 and 1.5%, respectively for HBP (P < 0.001/<0.01, for comparisons respectively). Nighttime BP monitoring and cuff discomfort were the main complaints for ABP (46 and 32%, respectively) and HBP (34 and 28%), whereas 89% reported more nighttime sleep disturbance by ABP than HBP (P < 0.001). CONCLUSIONS HBP monitoring appears to be a reliable and well accepted by users alternative to ABP for the assessment of nocturnal BP and the detection of non-dippers.
引用
收藏
页码:974 / 978
页数:5
相关论文
共 18 条
[1]  
Beltman FW, 1996, J HUM HYPERTENS, V10, pS39
[2]   Device for the self-measurement of blood pressure that can monitor blood pressure during sleep [J].
Chonan, K ;
Kikuya, M ;
Araki, T ;
Fujiwara, T ;
Suzuki, M ;
Michimata, M ;
Hashimoto, J ;
Ohkubo, T ;
Hozawa, A ;
Yamamoto, N ;
Miyawaki, Y ;
Matsubara, M ;
Imai, Y .
BLOOD PRESSURE MONITORING, 2001, 6 (04) :203-205
[3]  
DABL Educational Trust, DEV BLOOD PRESS MEAS
[4]   Night-day blood pressure ratio and dipping pattern as predictors of death and cardiovascular events in hypertension [J].
Fagard, R. H. ;
Thijs, L. ;
Staessen, J. A. ;
Clement, D. L. ;
De Buyzere, M. L. ;
De Bacquer, D. A. .
JOURNAL OF HUMAN HYPERTENSION, 2009, 23 (10) :645-653
[5]   Reproducibility of nocturnal blood pressure assessed by self-measurement of blood pressure at home [J].
Hosohata, Keiko ;
Kikuya, Masahiro ;
Ohkubo, Takayoshi ;
Metoki, Hirohito ;
Asayama, Kei ;
Inoue, Ryusuke ;
Obara, Taku ;
Hashimoto, Junichiro ;
Totsune, Kazuhito ;
Hoshi, Haruhisa ;
Satoh, Hiroshi ;
Imai, Yutaka .
HYPERTENSION RESEARCH, 2007, 30 (08) :707-712
[6]   Comparison of acceptability of and preferences for different methods of measuring blood pressure in primary care [J].
Little, P ;
Barnett, J ;
Barnsley, L ;
Marjoram, J ;
Fitzgerald-Barron, A ;
Mant, D .
BRITISH MEDICAL JOURNAL, 2002, 325 (7358) :258-259
[7]   Self blood pressure monitoring: a worthy substitute for ambulatory blood pressure? [J].
McGowan, N. ;
Padfield, P. L. .
JOURNAL OF HUMAN HYPERTENSION, 2010, 24 (12) :801-806
[8]   Nocturnal dipping is reproducible in the long term [J].
McGowan, Neil J. ;
Gough, Kathleen ;
Padfield, Paul L. .
BLOOD PRESSURE MONITORING, 2009, 14 (05) :185-189
[9]  
National Institute for Health and Clinical Excellence (NICE), 2011, CLIN MAN PRIM HYP AD
[10]   European Society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement [J].
O'Brien, E ;
Asmar, R ;
Beilin, L ;
Imai, Y ;
Mallion, JM ;
Mancia, G ;
Mengden, T ;
Myers, M ;
Padfield, P ;
Palatini, P ;
Parati, G ;
Pickering, T ;
Redon, J ;
Staessen, J ;
Stergiou, G ;
Verdecchia, P .
JOURNAL OF HYPERTENSION, 2003, 21 (05) :821-848