HbA1c: A Review of Analytical and Clinical Aspects

被引:279
作者
Weykamp, Cas [1 ]
机构
[1] Queen Beatrix Hosp, MCA Lab, NL-7101 BN Winterswijk, Netherlands
关键词
HbA1c; Diabetes; Standardization; Analytical aspects; Clinical aspects; GLYCOHEMOGLOBIN STANDARDIZATION PROGRAM; HEMOGLOBIN A(1C) MEASUREMENT; ASSAY; RECOMMENDATIONS; DIAGNOSIS; HBA(1C); SYSTEM; BLOOD; GOALS; LONG;
D O I
10.3343/alm.2013.33.6.393
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
After the relationship between glycemic control and the HbA1c concentration was demonstrated, many tests have been developed to determine the HbA1c concentration. The test results are standardized to the International Federation of Clinical Chemistry (IFCC) Reference Measurement Procedure (RMP) in harmony with the efforts of the National Glycohemoglobin Standardization Program (NGSP). The longitudinal use of the test requires strict quality management including accreditation of the laboratory, a dedicated internal control design, participation in an external quality assessment (EQA) program (proficiency test), and careful consideration of pre- and post-analytical aspects of the test. Performance goals for optimizing determination of the HbA1c concentration have been described. As an index of long-term glycemic control and a risk predictor, the HbA1c concentration is an indispensable part of routine management of diabetes. Because of the improving quality of the test, the HbA1c concentration is being increasingly applied in the diagnosis of diabetes. There are, however, concerns of this application in point-of-care settings. The HbA1c concentration is also used to achieve stringent control in pregnant diabetic patients. Strict standardization enables the definition of universal reference values and clinical decision limits. This review describes the present status of analytical and clinical aspects of determining the HbA1c concentration and highlights the challenges involved.
引用
收藏
页码:393 / 400
页数:8
相关论文
共 34 条
[1]  
Amer Diabet Assoc, 2011, DIABETES CARE, V34, pS11, DOI [10.2337/dc10-S062, 10.2337/dc14-S081, 10.2337/dc11-S011, 10.2337/dc13-S011, 10.2337/dc13-S067, 10.2337/dc12-s064, 10.2337/dc11-S062, 10.2337/dc10-S011, 10.2337/dc12-s011]
[2]  
American Diabetes Association, 2010, DIABETES CARE, V33, pS11, DOI DOI 10.2337/dc10-S011
[3]  
[Anonymous], US GLYC HAEM ABZ1C D
[4]  
[Anonymous], HbA1c assay interferences
[5]  
[Anonymous], J JPN DIABETES SOC
[6]   Diabetes research and diabetes care - Where do we stand? [J].
Davidson, MB .
DIABETES CARE, 1998, 21 (12) :2152-2160
[7]   Consensus statement on the worldwide standardization of the hemoglobin A1C measurement - The American Diabetes Association, European Association for the Study of Diabetes, International Federation of Clinical Chemistry and Laboratory Medicine, and the International Diabetes Federation [J].
Hicks, Jocelyn ;
Muller, Mathias ;
Panteghini, Mauro ;
John, Garry ;
Deeb, Larry ;
Buse, John ;
Nathan, David M. ;
Kahn, Richard ;
Ferrannini, Ele ;
Heine, Robert ;
Silink, Martin ;
Mbanya, Jean-Claude .
DIABETES CARE, 2007, 30 (09) :2399-2400
[8]   IFCC reference system for measurement of hemoglobin Alc in human blood and the National Standardization Schemes in the United States, Japan, and Sweden:: A method-comparison study [J].
Hoelzel, W ;
Weykamp, C ;
Jeppsson, JO ;
Miedema, K ;
Barr, JR ;
Goodall, I ;
Hoshino, T ;
John, WG ;
Kobold, U ;
Little, R ;
Mosca, A ;
Mauri, P ;
Paroni, R ;
Susanto, F ;
Takei, I ;
Thienpont, L ;
Umemoto, M ;
Wiedmeyer, HM .
CLINICAL CHEMISTRY, 2004, 50 (01) :166-174
[9]   First evaluation of Capillarys 2 Flex Piercing® (Sebia) as a new analyzer for HbA1c assay by capillary electrophoresis [J].
Jaisson, Stephane ;
Leroy, Nathalie ;
Meurice, Julie ;
Guillard, Emmanuelle ;
Gillery, Philippe .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (10) :1769-1775
[10]   Approved IFCC reference method for the measurement of HbA1c in human blood [J].
Jeppsson, JO ;
Kobold, U ;
Barr, J ;
Finke, A ;
Hoelzel, W ;
Hoshino, T ;
Miedema, K ;
Mosca, A ;
Mauri, P ;
Paroni, R ;
Thienpont, L ;
Umemoto, M ;
Weykamp, C .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (01) :78-89