Reproducibility of Tumor Perfusion Measurements Using 15O-Labeled Water and PET

被引:45
作者
de Langen, Adrianus J. [2 ]
Lubberink, Mark [1 ]
Boellaard, Ronald [1 ]
Spreeuwenberg, Marieke D. [3 ]
Smit, Egbert F. [2 ]
Hoekstra, Otto S. [1 ]
Lammertsma, Adriaan A. [1 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Nucl Med & PET Res, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Resp Med, NL-1007 MB Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Dept Clin Epidemiol & Biostat, NL-1007 MB Amsterdam, Netherlands
关键词
positron emission tomography; blood flow; perfusion; non-small-cell lung cancer;
D O I
10.2967/jnumed.108.053454
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET and O-15-labeled water ((H2O)-O-15) can be used to noninvasively monitor tumor perfusion. This allows evaluation of the direct target of antiangiogenic drugs, that is, tumor vasculature. Because these drugs often result in consolidation rather than regression of the tumor mass, a change in perfusion might be a more sensitive way to evaluate response than are indirect size measures on a CT scan. However, to use the technique for serial imaging of individual patients, good reproducibility is essential. The purpose of the present study was to evaluate the reproducibility of quantitative (H2O)-O-15 measurements. Methods: Nine patients with non-small-cell lung cancer (NSCLC) were scanned twice within 7 d and before any therapy. All (H2O)-O-15 scans were followed by an F-18-fluorothymidine scan to allow for adequate volume-of-interest (VOI) definition. VOIs were defined using a 3-dimensional threshold technique. Tumor perfusion and the volume of distribution (V-T) were obtained using a 1-tissue-compartment model including an arterial blood volume component and an image-derived input function. The level of agreement between test and retest values was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analyses. Possible dependency on absolute values and lesion size was assessed by linear regression. Results: All primary tumors and more than 90% of clinically suspected locoregional metastases could be delineated. In total, 14 lesions in 9 patients were analyzed. Tumor perfusion showed excellent reproducibility, with an ICC of 0.95 and SD of 9%. The V-T was only moderately reproducible, with an ICC of 0.52 and SD of 16%. No dependency was found on absolute values of perfusion (P = 0.14) and V-T (P = 0.15). In addition, tumor volume did not influence the reproducibility of perfusion (P = 0.46) and V-T (P = 0.25). Conclusion: Quantitative measurements of tumor perfusion using (H2O)-O-15 and PET are reproducible in NSCLC. When patients are repeatedly being scanned during therapy, changes of more than 18% in tumor perfusion and 32% in V-T (>1.96 x SD) are likely to represent treatment effects.
引用
收藏
页码:1763 / 1768
页数:6
相关论文
共 50 条
[41]   Alignment of 3-dimensional cardiac structures in O-15-labeled water PET emission images with mutual information [J].
Anu Juslin ;
Jyrki Lötjönen ;
Sergey V. Nesterov ;
Kari Kalliokoski ;
Juhani Knuuti ;
Ulla Ruotsalainen .
Journal of Nuclear Cardiology, 2007, 14 :82-91
[42]   Alignment of 3-dimensional cardiac structures in O-15-labeled water PET emission images with mutual information [J].
Juslin, Anu ;
Lotjonen, Jyrki ;
Nesterov, Sergey V. ;
Kalliokoski, Kari ;
Knuuti, Juhani ;
Ruotsalainen, Ulla .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (01) :82-91
[43]   Effects of patient movement on measurements of myocardial blood flow and viability in resting 15O-water PET studies [J].
Koshino, Kazuhiro ;
Watabe, Hiroshi ;
Enmi, Junichiro ;
Hirano, Yoshiyuki ;
Zeniya, Tsutomu ;
Hasegawa, Shinji ;
Hayashi, Takuya ;
Miyagawa, Shigeru ;
Sawa, Yoshiki ;
Hatazawa, Jun ;
Iida, Hidehiro .
JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (03) :524-533
[44]   82Rb and [15O]H2O myocardial perfusion PET imaging: a prospective head to head comparison [J].
Krakauer, Martin ;
Ismail, Afefah ;
Talleruphuus, Ulrik ;
Henriksen, Alexander Cuculiza ;
Lonsdale, Markus N. ;
Rasmussen, Inge Lise ;
Fuglsang, Stefan ;
Prescott, Eva ;
Hovind, Peter ;
Marner, Lisbeth .
JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (06) :2790-2802
[45]   Noninvasive parametric blood flow imaging of head and neck tumours using [15O]H2O and PET/CT [J].
Komar, Gaber ;
Oikonen, Vesa ;
Sipila, Hannu ;
Seppanen, Marko ;
Minn, Heikki .
NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (11) :1169-1178
[46]   Repeatability and reproducibility of optic nerve head perfusion measurements using optical coherence tomography angiography [J].
Chen, Chieh-Li ;
Bojikian, Karine D. ;
Xin, Chen ;
Wen, Joanne C. ;
Gupta, Divakar ;
Zhang, Qinqin ;
Mudumbai, Raghu C. ;
Johnstone, Murray A. ;
Chen, Philip P. ;
Wang, Ruikang K. .
JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)
[47]   Evaluation of Arterial Spin Labeling MRI-Comparison with 15O-Water PET on an Integrated PET/MR Scanner [J].
Fahlstrom, Markus ;
Appel, Lieuwe ;
Kumlien, Eva ;
Danfors, Torsten ;
Engstrom, Mathias ;
Wikstrom, Johan ;
Antoni, Gunnar ;
Larsson, Elna-Marie ;
Lubberink, Mark .
DIAGNOSTICS, 2021, 11 (05)
[48]   Synthesis and bioimaging of positron-emitting 15O-labeled 2-deoxy-D-glucose of two-minute half-life [J].
Yorimitsu, Hideki ;
Murakami, Yoshihiro ;
Takamatsu, Hiroyuki ;
Nishimura, Shintaro ;
Nakamura, Eiichi .
CHEMISTRY-AN ASIAN JOURNAL, 2007, 2 (01) :57-65
[49]   Cerebral blood flow measurements with 15O-water PET using a non-invasive machine-learning-derived arterial input function [J].
Kuttner, Samuel ;
Wickstrom, Kristoffer Knutsen ;
Lubberink, Mark ;
Tolf, Andreas ;
Burman, Joachim ;
Sundset, Rune ;
Jenssen, Robert ;
Appel, Lieuwe ;
Axelsson, Jan .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2021, 41 (09) :2229-2241
[50]   Assessment of Interobserver Reproducibility in Quantitative 18F-FDG PET and CT Measurements of Tumor Response to Therapy [J].
Jacene, Heather A. ;
Leboulleux, Sophie ;
Baba, Shingo ;
Chatzifotiadis, Daniel ;
Goudarzi, Behnaz ;
Teytelbaum, Oleg ;
Horton, Karen M. ;
Kamel, Ihab ;
Macura, Katarzyna J. ;
Tsai, Hua-Ling ;
Kowalski, Jeanne ;
Wahl, Richard L. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (11) :1760-1769