Reproducibility of Tumor Perfusion Measurements Using 15O-Labeled Water and PET

被引:46
|
作者
de Langen, Adrianus J. [2 ]
Lubberink, Mark [1 ]
Boellaard, Ronald [1 ]
Spreeuwenberg, Marieke D. [3 ]
Smit, Egbert F. [2 ]
Hoekstra, Otto S. [1 ]
Lammertsma, Adriaan A. [1 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Nucl Med & PET Res, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Resp Med, NL-1007 MB Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Dept Clin Epidemiol & Biostat, NL-1007 MB Amsterdam, Netherlands
关键词
positron emission tomography; blood flow; perfusion; non-small-cell lung cancer;
D O I
10.2967/jnumed.108.053454
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET and O-15-labeled water ((H2O)-O-15) can be used to noninvasively monitor tumor perfusion. This allows evaluation of the direct target of antiangiogenic drugs, that is, tumor vasculature. Because these drugs often result in consolidation rather than regression of the tumor mass, a change in perfusion might be a more sensitive way to evaluate response than are indirect size measures on a CT scan. However, to use the technique for serial imaging of individual patients, good reproducibility is essential. The purpose of the present study was to evaluate the reproducibility of quantitative (H2O)-O-15 measurements. Methods: Nine patients with non-small-cell lung cancer (NSCLC) were scanned twice within 7 d and before any therapy. All (H2O)-O-15 scans were followed by an F-18-fluorothymidine scan to allow for adequate volume-of-interest (VOI) definition. VOIs were defined using a 3-dimensional threshold technique. Tumor perfusion and the volume of distribution (V-T) were obtained using a 1-tissue-compartment model including an arterial blood volume component and an image-derived input function. The level of agreement between test and retest values was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analyses. Possible dependency on absolute values and lesion size was assessed by linear regression. Results: All primary tumors and more than 90% of clinically suspected locoregional metastases could be delineated. In total, 14 lesions in 9 patients were analyzed. Tumor perfusion showed excellent reproducibility, with an ICC of 0.95 and SD of 9%. The V-T was only moderately reproducible, with an ICC of 0.52 and SD of 16%. No dependency was found on absolute values of perfusion (P = 0.14) and V-T (P = 0.15). In addition, tumor volume did not influence the reproducibility of perfusion (P = 0.46) and V-T (P = 0.25). Conclusion: Quantitative measurements of tumor perfusion using (H2O)-O-15 and PET are reproducible in NSCLC. When patients are repeatedly being scanned during therapy, changes of more than 18% in tumor perfusion and 32% in V-T (>1.96 x SD) are likely to represent treatment effects.
引用
收藏
页码:1763 / 1768
页数:6
相关论文
共 50 条
  • [1] Assessment of the reproducibility of baseline and hyperemic myocardial blood flow measurements with 15O-labeled water and PET
    Kaufmann, PA
    Gnecchi-Ruscone, T
    Yap, JT
    Rimoldi, O
    Camici, PG
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (11) : 1848 - 1856
  • [2] Reproducibility of semi-automated hepatic perfusion measurements using 15O-water PET
    Lubberink, M.
    Runesson, P.
    Lindstrom, E.
    Roslin, S.
    Vessby, J.
    Antoni, G.
    Rorsman, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S297 - S297
  • [3] Quantification of sublendocardial and sublepicardial blood flow using 15O-labeled water and PET:: Experimental validation
    Rimoldi, O
    Schäfers, KP
    Boellaard, R
    Turkheimer, F
    Stegger, L
    Law, MP
    Lammerstma, AA
    Camici, PG
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (01) : 163 - 172
  • [4] Feasibility of subendocardial and subepicardial myocardial perfusion measurements in healthy normals with 15O-labeled water and positron emission tomography
    Rutten-Vermeltfoort, I.
    Raijmakers, P. G. H. M.
    Lubberink, M.
    Germans, T.
    Van Rosum, A. C.
    Lammertsma, A. A.
    Knaapen, P.
    EUROPEAN HEART JOURNAL, 2011, 32 : 983 - 984
  • [5] Feasibility of subendocardial and subepicardial myocardial perfusion measurements in healthy normals with 15O-labeled water and positron emission tomography
    Vermeltfoort, Ilse A.
    Raijmakers, Pieter G.
    Lubberink, Mark
    Germans, Tjeerd
    van Rossum, Albert C.
    Lammertsma, Adriaan A.
    Knaapen, Paul
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (04) : 650 - 656
  • [6] Feasibility of subendocardial and subepicardial myocardial perfusion measurements in healthy normals with 15O-labeled water and positron emission tomography
    Ilse A. Vermeltfoort
    Pieter G. Raijmakers
    Mark Lubberink
    Tjeerd Germans
    Albert C. van Rossum
    Adriaan A. Lammertsma
    Paul Knaapen
    Journal of Nuclear Cardiology, 2011, 18 : 650 - 656
  • [7] Positron emission tomography:: measurement of myocardial perfusion using 13N-labeled ammonia and 15O-labeled water
    Blanksma, PK
    Pruim, J
    METHODS, 2002, 27 (03) : 226 - 227
  • [8] Localization of language-related cortex with 15O-labeled water PET in patients with gliomas
    Thiel, A
    Herholz, K
    von Stockhausen, HM
    van Leyen-Pilgram, K
    Pietrzyk, U
    Kessler, J
    Wienhard, K
    Klug, N
    Heiss, WD
    NEUROIMAGE, 1998, 7 (04) : 284 - 295
  • [9] Quantitative Parametric Perfusion Images Using 15O-Labeled Water and a Clinical PET/CT Scanner: Test-Retest Variability in Lung Cancer
    van der Veldt, Astrid A. M.
    Hendrikse, N. Harry
    Harms, Hendrik J.
    Comans, Emile F. I.
    Postmus, Pieter E.
    Smit, Egbert F.
    Lammertsma, Adriaan A.
    Lubberink, Mark
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (11) : 1684 - 1690
  • [10] Tumor Blood Flow Measured by Perfusion Computed Tomography and 15O-Labeled Water Positron Emission Tomography: A Comparison Study
    Ng, Chaan S.
    Kodama, Yoshihisa
    Mullani, Nizar A.
    Barron, Bruce J.
    Wei, Wei
    Herbst, Roy S.
    Abbruzzese, James L.
    Charnsangavej, Chusilp
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (03) : 460 - 465