Risk factors of incomplete thrombosis in the false lumen after endovascular treatment of extensive acute type B aortic dissection

被引:76
作者
Qin, Yong-Lin [1 ]
Deng, Gang [1 ]
Li, Tian-Xiao [3 ]
Jing, Rui-Wei [2 ]
Teng, Gao-Jun [1 ]
机构
[1] Southeast Univ, Zhongda Hosp, Sch Med, Dept Intervent Radiol & Vasc Surg, Nanjing 210009, Peoples R China
[2] Southeast Univ, Dept Stat, Sch Publ Hlth, Nanjing 210009, Peoples R China
[3] Henan Prov Peoples Hosp, Dept Intervent Radiol, Zhengzhou, Peoples R China
关键词
COMPLICATED ACUTE; DESCENDING AORTA; REPAIR; ECHOCARDIOGRAPHY; PREDICTOR; PROGNOSIS; DIAMETER; TEARS;
D O I
10.1016/j.jvs.2012.04.019
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study evaluated the risk factors of incomplete thrombosis in the false lumen after thoracic endovascular aortic repair (TEVAR) in patients with extensive acute type B aortic dissection. Methods: This was a retrospective study at Zhongda Hospital and Henan Provincial People's Hospital, China. Between January 2005 and May 2008, patients with acute type B dissection who underwent TEVAR at two centers were reviewed and 124 who met the following criteria were included in this study: (1) dissection involving the aorta below the level of the celiac artery, (2) completely patent false lumen at the time of intervention, and (3) complete initial diagnostic computed tomography (CT) scans and all follow-up CT scans available. Exclusion criteria were (1) aortic dissection secondary to trauma, (2) intramural hematoma, and (3) Marfan patients. The main outcome measures were demographics, comorbidity profiles, technical details of procedures, anatomic characteristics of dissection, and false lumen status of thrombosis during follow-up. Ordinal regression analysis was performed with variables that reached P < .20 on univariate analysis to investigate independent risk factors of incomplete thrombosis in the false lumen. Results: Univariate analysis showed that the age at TEVAR, hypertension, maximum diameter of the abdominal aorta and false lumen at the abdominal level, re-entry tears, and visceral branches that arose partially or totally from the false lumen had a P < .20. Further analysis with an ordinal regression model showed that the visceral branches that arose partially or totally from the false lumen (odds ratio [OR], 10.054; P < .001), re-entry tears (OR, 30.661; P < .001), and maximum diameter of the false lumen on the abdominal aorta (OR, 1.265; P = .004) were the significant risk factors of incomplete thrombosis in the false lumen after TEVAR. Conclusions: Visceral branches that arose partially or totally from the false lumen, re-entry tears, and maximum diameter of the false lumen on the abdominal aorta were the risk factors of incomplete thrombosis in the false lumen after TEVAR in extensive acute type B dissection. (J Vasc Surg 2012;56:1232-8.)
引用
收藏
页码:1232 / 1238
页数:7
相关论文
共 37 条
  • [1] Effects of the patent false lumen on the long-term outcome Iq of type B acute aortic dissection
    Akutsu, K
    Nejima, J
    Kiuchi, K
    Sasaki, K
    Ochi, M
    Tanaka, K
    Takano, T
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (02) : 359 - 366
  • [2] False lumen patency as a predictor of late outcome in aortic dissection
    Bernard, Y
    Zimmermann, H
    Chocron, S
    Litzler, JF
    Kastler, B
    Etievent, JP
    Meneveau, N
    Schiele, F
    Bassand, JP
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (12) : 1378 - 1382
  • [3] Aortic Diameter, True Lumen, and False Lumen Growth Rates in Chronic Type B Aortic Dissection
    Blount, Kevin J.
    Hagspiel, Klaus D.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05) : W222 - W229
  • [4] Czermak BV, 2004, J ENDOVASC THER, V11, P1, DOI 10.1583/1545-1550(2004)011<0001:SCVATL>2.0.CO
  • [5] 2
  • [6] Endovascular stent-graft placement for the treatment of acute aortic dissection
    Dake, MD
    Kato, N
    Mitchell, RS
    Semba, CP
    Razavi, MK
    Shimono, T
    Hirano, T
    Takeda, K
    Yada, I
    Miller, DC
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (20) : 1546 - 1552
  • [7] DISSECTING ANEURYSM OF AORTA - AORTOGRAPHIC FEATURES AFFECTING PROGNOSIS
    DINSMORE, RE
    WILLERSON, JT
    BUCKLEY, MJ
    [J]. RADIOLOGY, 1972, 105 (03) : 567 - +
  • [8] Midterm Results After Endovascular Treatment of Acute, Complicated Type B Aortic Dissection
    Ehrlich, Marek P.
    Dumfarth, Julia
    Schoder, Maria
    Gottardi, Roman
    Holfeld, Johannes
    Juraszek, Andrzej
    Dziodzio, Tomasz
    Funovics, Martin
    Loewe, Christian
    Grimm, Michael
    Sodeck, Gottfried
    Czerny, Martin
    [J]. ANNALS OF THORACIC SURGERY, 2010, 90 (05) : 1444 - 1449
  • [9] ERBEL R, 1989, LANCET, V1, P457
  • [10] EFFECT OF MEDICAL AND SURGICAL THERAPY ON AORTIC DISSECTION EVALUATED BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY - IMPLICATIONS FOR PROGNOSIS AND THERAPY
    ERBEL, R
    OELERT, H
    MEYER, J
    PUTH, M
    MOHRKATOLY, S
    HAUSMANN, D
    DANIEL, W
    MAFFEI, S
    CARUSO, A
    COVINO, FE
    DIALETTO, G
    IACONO, C
    COTRUFO, M
    BARONI, M
    TERRAZZI, M
    FRASER, A
    TAAMS, M
    SLAVICH, G
    SUTHERLAND, G
    ROELANDT, J
    MARCAGGI, X
    [J]. CIRCULATION, 1993, 87 (05) : 1604 - 1615