Are there any differences in three-dimensional placental vascular indices obtained using conventional power Doppler and high-definition flow imaging?

被引:5
作者
Rizzo, Giuseppe [1 ,2 ]
Pietrolucci, Maria Elena [1 ,2 ]
Aiello, Eloisa [1 ]
Dijmeli, Estelle [1 ]
Bosi, Costanza [1 ]
Arduini, Domenico [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Obstet & Gynecol, I-00186 Rome, Italy
[2] Univ Roma Tor Vergata, Fetal Med Ctr Genoma, I-00186 Rome, Italy
关键词
high definition Doppler imaging; power Doppler; three-dimensional Doppler angiography; three-dimensional ultrasound; placenta; ULTRASOUND; REPRODUCIBILITY; SONOGRAPHY; VOLUME; COLOR;
D O I
10.3109/14767058.2012.657274
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The purpose of this study was to determine whether there are differences in values and reproducibility of three-dimensional (3D) vascular indices obtained on placental volumes using power Doppler (PD) or high-definition flow imaging (HDFI) techniques. Methods: A prospective study was performed on 121 uncomplicated singleton pregnancies at 11 + 0 to 13 + 6 weeks of gestation. Two placental volumes were acquired from each pregnancy. Vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were then analyzed and compared. In order to assess the reproducibility of the measurements, two additional placental volumes obtained with both PD and HDFI were acquired in 31 pregnancies and the agreement assessed by intraclass correlation coefficients. Inter-observer variability was assessed by analyzing all the volumes by two observers blinded to each other's. Results: A significant relationship was observed between the vascular indices values obtained with the two techniques (VI Pearson's r = 0.891 p < 0.001; FI r = 0.769 p < 0.001; VFI r = 0.847 p < 0.001). The median values of VI, FI and VFI were significantly higher when obtained with HDFI imaging. In serial recordings, the ICCs resulted higher when volumes were acquired with HDFI rather than with PD techniques. Similarly, HDFI demonstrated a higher inter-observer reproducibility. Conclusions: 3D vascular indices calculated using HDFI are higher than those calculated using conventional PD. Although the relationship between the two methods is high, HDFI shows a better reproducibility suggesting its potential clinical application.
引用
收藏
页码:1664 / 1667
页数:4
相关论文
共 16 条
[1]   Three-dimensional power Doppler derived vascular indices:: what are we measuring and how are we doing it? [J].
Alcazar, J. L. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 32 (04) :485-487
[2]  
FLEISS J, 1981, STAT METHODS RATES P, P191
[3]   Is three-dimensional power Doppler ultrasound useful in the assessment of placental perfusion in normal and growth-restricted pregnancies? [J].
Guiot, C. ;
Gaglioti, P. ;
Oberto, M. ;
Piccoli, E. ;
Rosato, R. ;
Todros, T. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (02) :171-176
[4]   Three-dimensional ultrasound evaluation of the placenta [J].
Hata, T. ;
Tanaka, H. ;
Noguchi, J. ;
Hata, K. .
PLACENTA, 2011, 32 (02) :105-115
[5]   Reproducibility of Placental Volume and Vasculature Indices Obtained by 3-Dimensional Power Doppler Sonography [J].
Huster, Kristina M. ;
Haas, Kimberly ;
Schoenborn, Jean ;
McVean, Dominique ;
Odibo, Anthony O. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (06) :911-916
[6]   High-definition flow Doppler ultrasonographic technique to assess hepatic vasculature compared with color or power Doppler ultrasonography - Preliminary experience [J].
Kim, Se Hyung ;
Lee, Jeong Min ;
Kim, Young Jun ;
Lee, Jae Young ;
Han, Joon Koo ;
Choi, Byung Ihn .
JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (10) :1491-1501
[7]   Three-Dimensional Vascular Indices Calculated Using Conventional Power Doppler and High-Definition Flow Imaging Are There Differences? [J].
Luis Alcazar, Juan ;
Kudla, Marek J. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (05) :761-766
[8]   A STUDY OF PLACENTAL BED SPIRAL ARTERIES AND TROPHOBLAST INVASION IN NORMAL AND SEVERE PREECLAMPTIC PREGNANCIES [J].
MEEKINS, JW ;
PIJNENBORG, R ;
HANSSENS, M ;
MCFADYEN, IR ;
VANASSHE, A .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1994, 101 (08) :669-674
[9]   Reproducibility of the study of placental vascularization by three-dimensional power Doppler [J].
Mercé, LT ;
Barco, MJ ;
Bau, S .
JOURNAL OF PERINATAL MEDICINE, 2004, 32 (03) :228-233
[10]   Placental volume and vascular flow assessed by 3D power Doppler and adverse pregnancy outcomes [J].
Odibo, A. O. ;
Goetzinger, K. R. ;
Huster, K. M. ;
Christiansen, J. K. ;
Odibo, L. ;
Tuuli, M. G. .
PLACENTA, 2011, 32 (03) :230-234