Prediction of measurement error due to low gray scale and spatial resolution of an imaging system on quantification of neutron radiographic image

被引:4
作者
Hibiki, T [1 ]
Mishima, K [1 ]
机构
[1] KYOTO UNIV,INST RES REACTOR,KUMATORI,OSAKA 59004,JAPAN
关键词
D O I
10.1016/S0168-9002(97)00315-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A study on the effects of image gray scale and pixel number on image quantification was performed analytically and experimentally in order to establish a method of measuring multiphase flows using neutron radiography. It was found from a simplified model that the resolution of an object thickness to be measured had a logarithmic characteristic for th object thickness, and there was a possibility that the measured void fraction in high- and low-void-fraction regions might include large error. It was shown from the numerical analysis that the measurement error would be within 5% except for the annular flow region with the void fraction greater than 90%, when void fraction of an air-water two-phase flow in a channel with the local gap smaller than 9 mm was measured under the condition of the image gray scale = 100. It was revealed from a simplified model that the error due to the number of pixels would be within 5% when the number of pixels projecting the object was ten times greater than that projecting the object boundary.