Determination of optimum high-side pressure of R744 automotive heat pump using Fibonacci search method

被引:0
作者
Glos, Jan [1 ]
Solc, Frantisek [1 ]
机构
[1] Brno Univ Technol, CEITEC Cent European Inst Technol, Brno, Czech Republic
来源
2017 IEEE 26TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE) | 2017年
基金
欧盟地平线“2020”;
关键词
CARBON-DIOXIDE; REJECTION PRESSURE; SYSTEMS; OPTIMIZATION; CYCLES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with maximizing coefficient of performance (COP) of R744 automotive heat pump. A high-side pressure variation is possible during transcritical operation employing low pressure receiver and electronic expansion valve (EXV). The optimal high-side pressure is then determined using Fibonacci search method. This approach is one of possible methods of online high-side pressure control and it has significant advantages over the offline methods. Employing this innovative method of R744 heat pump optimization a disadvantage of low COP during transcritical operation can be eliminated. Thus further usage of R744 refrigerant in automotive applications will be possible without any negative impact on energy consumption. As a result, this work can help with development of more environmental friendly vehicles.
引用
收藏
页码:448 / 453
页数:6
相关论文
共 13 条
  • [1] Efficient control of automotive R744 heat pump using Nelder-Mead simplex method
    Glos, Jan
    Vaclavek, Pavel
    2017 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2017, : 785 - 790
  • [2] PERFORMANCE OF REFRIGERATION & HEAT PUMP SYSTEM BY USING BINARY MIXTURES OF R32/R744
    Sun, Zhili
    Li, Minxia
    Ma, Yitai
    Wang, Pai
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 551 - 561
  • [3] PERFORMANCE SIMULATION OF A HEAT PUMP DRYING SYSTEM USING R744 AS REFRIGERANT
    Bantle, Michael
    Kvalsvik, Karoline H.
    Tolstorebrov, Ignat
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 244 - 251
  • [4] THERMODYNAMIC COMPARISION OF R744/R600A AND R744/R600 USED IN MID-HIGH TEMPERATURE HEAT PUMP SYSTEM
    Fan, Xiao-Wei
    Ju, Fu-Jun
    Zhang, Xian-Ping
    Wang, Fang
    THERMAL SCIENCE, 2014, 18 (05): : 1655 - 1659
  • [5] A real-time algorithm for the determination of R744 systems optimal high pressure
    Cecchinato, Luca
    Corradi, Marco
    Cosi, Giovanni
    Minetto, Silvia
    Rampazzo, Mirco
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (04): : 817 - 826
  • [6] Experimental investigation on performance of transcritical CO2 heat pump system with ejector under optimum high-side pressure
    Xu, Xiao Xiao
    Chen, Guang Ming
    Tang, Li Ming
    Zhu, Zhi Jiang
    ENERGY, 2012, 44 (01) : 870 - 877
  • [7] Experiment and simulation study on performances of heat pump water heater using blend of R744/R290
    Ju, Fujun
    Fan, Xiaowei
    Chen, Yaping
    Ouyang, Huaipu
    Kuang, Amin
    Ma, Shengfei
    Wang, Fang
    ENERGY AND BUILDINGS, 2018, 169 : 148 - 156
  • [9] Experimental investigation on a heat pump water heater using R744/R290 mixture for domestic hot water
    Ju, Fujun
    Fan, Xiaowei
    Chen, Yaping
    Wang, Tuanjie
    Tang, Xiangyang
    Kuang, Amin
    Ma, Shengfei
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 132 : 1 - 13
  • [10] Dynamic Modelling and Validation of an Air-to-Water Reversible R744 Heat Pump for High Energy Demand Buildings
    Artuso, Paolo
    Tosato, Giacomo
    Rossetti, Antonio
    Marinetti, Sergio
    Hafner, Armin
    Banasiak, Krzysztof
    Minetto, Silvia
    ENERGIES, 2021, 14 (24)