Determination of carbon monoxide concentration and total pressure in gas cavities in the silica glass body of light bulbs by FT-IR spectrometry

被引:5
作者
Bacsik, Z
Gyivicsán, A
Horváth, K
Mink, J
机构
[1] Hungarian Acad Sci, Chem Res Ctr, H-1025 Budapest, Hungary
[2] Univ Veszprem, Hungarian Acad Sci, Analyt Chem Res Grp, H-8200 Veszprem, Hungary
[3] Univ Veszprem, Dept Analyt Chem, H-8200 Veszprem, Hungary
[4] Univ Veszprem, Fac Informat Technol, Res Inst Chem & Proc Engn, H-8200 Veszprem, Hungary
关键词
D O I
10.1021/ac051843h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fourier transform infrared (FF-IR) spectroscopy has been adapted to control the quality of light bulbs made from silica glass. Such light bulbs contain a molybdenum accessory which, if contaminated with carbon, during the melting procedure of bulb fabrication, can cause the production of carbon monoxide. This CO can be trapped in small gas cavities in the silica glass body of the bulb. A method has been developed for the detection of CO and the total pressure within these gas cavities by traditional FT-IR spectrometry using a spectral resolution of 0.5 cm(-1). The concentration of CO was determined by using a classical least-squares (CLS) method, and the accuracy of concentration determination is reported for the case with sample and reference spectra recorded at different pressures. The total pressure in the cavities was established by two different methods: either by CLS fitting of reference spectra to sample spectra or fitting a Voigt line shape function to the spectral lines within the CO fundamental stretching band. In the latter method, the width of the lines was determined and pressure-broadening coefficients are given and compared with high-resolution data from the literature. According to the measurements, 0.55-0.80 atm total pressure and 0.8-4.0% (v/v) CO was determined in the gas cavities. Ibis method can also be applied to determine the total pressure in similar enclosed spaces in which an appropriate indicator gas component exists.
引用
收藏
页码:2382 / 2387
页数:6
相关论文
共 45 条
[1]   Diode laser absorption sensors for gas-dynamic and combustion flows [J].
Allen, MG .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (04) :545-562
[2]   ERRORS IN ABSORBANCE MEASUREMENTS IN INFRARED FOURIER-TRANSFORM SPECTROMETRY BECAUSE OF LIMITED INSTRUMENT RESOLUTION [J].
ANDERSON, RJ ;
GRIFFITHS, PR .
ANALYTICAL CHEMISTRY, 1975, 47 (14) :2339-2347
[3]   FTIR spectroscopy of the atmosphere Part 2. Applications [J].
Bacsik, Z ;
Mink, J ;
Keresztury, G .
APPLIED SPECTROSCOPY REVIEWS, 2005, 40 (04) :327-390
[4]   FTIR spectroscopy of the atmosphere. I. Principles and methods [J].
Bacsik, Z ;
Mink, J ;
Keresztury, G .
APPLIED SPECTROSCOPY REVIEWS, 2004, 39 (03) :295-363
[5]   FTIR emission spectroscopy methods and procedures for real time quantitative gas analysis in industrial environments [J].
Bak, J ;
Clausen, S .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (02) :150-156
[6]   Pressure broadening and line shift measurements of carbon monoxide in collision with helium from 1 to 600 K [J].
Beaky, MM ;
Goyette, TM ;
DeLucia, FC .
JOURNAL OF CHEMICAL PHYSICS, 1996, 105 (10) :3994-4004
[7]   Line shape analysis of O2 in air as a way to measure temperature using a DFB-diode-laser at 761 nm [J].
Benedetti, R ;
Giulietti, K ;
Rosa-Clot, M .
OPTICS COMMUNICATIONS, 1998, 154 (1-3) :47-53
[8]   A MULTISPECTRUM NONLINEAR LEAST-SQUARES FITTING TECHNIQUE [J].
BENNER, DC ;
RINSLAND, CP ;
DEVI, VM ;
SMITH, MAH ;
ATKINS, D .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1995, 53 (06) :705-721
[9]   Spectral profiles for atmospheric absorption by isolated lines:: A comparison of model spectra with P- and R-branch lines of CO in N2 and Ar [J].
Berman, R ;
Sinclair, PM ;
May, AD ;
Drummond, JR .
JOURNAL OF MOLECULAR SPECTROSCOPY, 1999, 198 (02) :283-290
[10]   Temperature-dependent line shift and broadening of CO infrared transitions [J].
Drascher, T ;
Giesen, TF ;
Wang, TY ;
Schmücker, N ;
Schieder, R ;
Winnewisser, G ;
Joubert, P ;
Bonamy, J .
JOURNAL OF MOLECULAR SPECTROSCOPY, 1998, 192 (02) :268-276