A 75 keV, 140 mA proton injector

被引:26
作者
Sherman, JD
Figueroa, TL
Hansborough, LD
Kerstiens, DM
Schneider, JD
Smith, HV
Stettler, MW
Stevens, RR
Thuot, ME
Warren, DS
Zaugg, TJ
Arvin, AA
Bolt, AS
Boers, JE
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[2] Savannah River Site, Aiken, SC 29841 USA
[3] Thunderbird Simulat, Garland, TX 75042 USA
关键词
D O I
10.1063/1.1427671
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A do and pulsed-mode 75 keV proton injector has been developed and is used in characterization of a continuous-wave 6.7 MeV, 100 mA radio-frequency quadrupole (RFQ). The injector is used frequently at the full RFQ design power (100 mA, 6.7 MeV) where the RFQ admittance (1 rms, normalized) is 0.23 (pi mm mrad). The injector includes a 2.45 GHz microwave proton source and a beam space-charge-neutralized, two magnetic-solenoid, low-energy beam-transport system. The design RFQ beam transmission of 95% has been demonstrated at 100 mA RFQ output current. (C) 2002 American Institute of Physics.
引用
收藏
页码:917 / 921
页数:5
相关论文
共 22 条
[1]   Emittance improvement of the electron cyclotron resonance high intensity light ion source proton beam by gas injection in the low energy beam transport [J].
Beauvais, PY ;
Ferdinand, R ;
Gobin, R ;
Lagniel, JM ;
Leroy, PA ;
Celona, L ;
Ciavola, G ;
Gammino, S ;
Pottin, B ;
Sherman, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03) :1413-1416
[2]  
BOERS JE, P 1995 PART ACC C, P2312
[3]  
CHIDLEY BG, 1991, P 1990 LIN ACC C LOS, P42
[4]  
CRANDALL KR, P 1984 LIN ACC C, P581
[5]  
DALESIO L, P 1999 PART ACC C, P652
[6]  
FERDINAND R, P 1997 PART ACC C, P2723
[7]  
GILPATRICK JD, P 1999 PART ACC C, P2214
[8]   Status and new developments of the high intensity electron cyclotron resonance source light ion continuous wave, and pulsed mode (invited) [J].
Lagniel, JM ;
Beauvais, PY ;
Bogard, D ;
Bourdelle, G ;
Charruau, G ;
Delferrière, O ;
De Menezes, D ;
France, A ;
Ferdinand, R ;
Gauthier, Y ;
Gobin, R ;
Harrault, F ;
Jannin, JL ;
Leroy, PA ;
Yao, I ;
Ausset, P ;
Pottin, B ;
Rouvière, N ;
Celona, L ;
Gammino, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02) :830-835
[9]  
PICHOFF N, UNPUB
[10]  
REISER M, 1994, THEORY DESIGN CHARGE, P66