Do Plain Radiographs Correlate With CT for Imaging of Cam-type Femoroacetabular Impingement?

被引:103
作者
Nepple, Jeffrey J. [1 ]
Martel, John M. [2 ]
Kim, Young-Jo [3 ]
Zaltz, Ira [4 ]
Clohisy, John C. [1 ]
机构
[1] Washington Univ Sch Med, Dept Orthopaed Surg, St Louis, MO 63130 USA
[2] Univ Chicago, Chicago, IL 60637 USA
[3] Childrens Hosp, Dept Orthopaed Surg, Boston, MA 02115 USA
[4] William Beaumont Hosp, Royal Oak, MI 48072 USA
关键词
REVISION HIP ARTHROSCOPY; HEAD-NECK JUNCTION; POLYETHYLENE WEAR; ALPHA ANGLE; ARTHROPLASTY; ASPHERICITY; PREDICTOR; DEFORMITY; MRI;
D O I
10.1007/s11999-012-2510-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Three-dimensional imaging (CT and MRI) is the gold standard for detecting femoral head-neck junction malformations in femoroacetabular impingement, yet plain radiographs are used for initial diagnostic evaluation. It is unclear, however, whether the plain radiographs accurately reflect the findings on three-dimensional imaging. Questions/Purposes We therefore: (1) investigated the correlation of alpha angle measurements on plain radiographs and radial reformats of CT scans; (2) determined which radiographic views are most sensitive and specific in detecting head-neck deformities present on CT scans; and (3) determined if specific radiographic views correlated with specific locations on the radial oblique CT scan. Methods We retrospectively reviewed 41 surgical patients with preoperative CT scans (radial oblique reformats) and plain radiographs (AP pelvis, 45 degrees Dunn, frog lateral, and crosstable lateral). Alpha angles were measured on plain radiographs and CT reformats. Results The complete radiographic series was 86% to 90% sensitive in detecting abnormal alpha angles on CT. The maximum alpha angle on plain radiographs was greater than that of CT reformats in 61% of cases. Exclusion of the crosstable lateral did not affect the sensitivity (86%-88%). The Dunn view was most sensitive (71%-80%). The frog lateral showed the best specificity (91%-100%). Substantial correlations (intraclass correlation coefficients, 0.64-0.75) between radiograph and radial oblique CT position were observed, including AP/12:00 (superior), Dunn/1:00 (anterolateral), frog/3:00 (anterior), and crosstable/3:00 (anterior). Conclusions For diagnostic and treatment purposes, a three-view radiographic hip series (AP pelvis, 45 degrees Dunn, and frog lateral) effectively characterizes femoral headneck junction malformations.
引用
收藏
页码:3313 / 3320
页数:8
相关论文
共 24 条
[1]   Validity of the Alpha Angle Measurement on Plain Radiographs in the Evaluation of Cam-type Femoroacetabular Impingement [J].
Barton, Cefin ;
Salineros, Matias J. ;
Rakhra, Kawan S. ;
Beaule, Paul E. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :464-469
[2]   Three-dimensional computed tomography of the hip in the assessment of femoroacetabular impingement [J].
Beaulé, PE ;
Zaragoza, E ;
Motamedi, K ;
Copelan, N ;
Dorey, FJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (06) :1286-1292
[3]   Radiographic Comparison of Surgical Hip Dislocation and Hip Arthroscopy for Treatment of Cam Deformity in Femoroacetabular Impingement [J].
Bedi, Asheesh ;
Zaltz, Ira ;
De La Torre, Katrina ;
Kelly, Bryan T. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 :20S-28S
[4]  
Carlisle John C, 2011, Iowa Orthop J, V31, P52
[5]   The frog-leg lateral radiograph accurately visualized hip cam impingement abnormalities [J].
Clohisy, John C. ;
Nunley, Ryan M. ;
Otto, Robert J. ;
Schoenecker, Perry L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (462) :115-121
[6]   Femoroacetabular cam-type impingement: Diagnostic sensitivity and specificity of radiographic views compared to radial MRI [J].
Domayer, S. E. ;
Ziebarth, K. ;
Chan, J. ;
Bixby, S. ;
Mamisch, T. C. ;
Kim, Y. J. .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) :805-810
[7]   Do Normal Radiographs Exclude Asphericity of the Femoral Head-Neck Junction? [J].
Dudda, Marcel ;
Albers, Christoph ;
Mamisch, Tallal Charles ;
Werlen, Stefan ;
Beck, Martin .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (03) :651-659
[8]   Radiologic and Intraoperative findings in revision hip arthroscopy [J].
Heyworth, Benton E. ;
Shindle, Michael K. ;
Voos, James E. ;
Rudzki, Jonas R. ;
Kelly, Bryan T. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (12) :1295-1302
[9]   Effective dose and energy imparted in diagnostic radiology [J].
Huda, W ;
Gkanatsios, NA .
MEDICAL PHYSICS, 1997, 24 (08) :1311-1316
[10]   Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty [J].
Hui, AJ ;
McCalden, FW ;
Martell, JM ;
MacDonald, SJ ;
Bourne, RB ;
Rorabeck, CH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (03) :505-511