Fast charge preamplifier for high -sensitivity fission chamber

被引:5
作者
Yuan, Guoliang [1 ]
Yang, Qingwei [1 ]
Wen, Zuowei [1 ]
Zhao, Li [1 ]
Wei, Lingfeng [1 ]
Li, Yong [1 ]
机构
[1] Southwestern Inst Phys, Chengdu 610225, Peoples R China
基金
中国国家自然科学基金;
关键词
NEUTRON-FLUX MONITOR; DETECTOR; TIME;
D O I
10.1016/j.nima.2020.163977
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fast preamplifier was built with discrete JFET and operational amplifier for high-sensitivity fission chamber detector. Noise characteristics of preamplifier and detector were researched through measuring equivalent noise charge, processing the preamplifier output and analyzing pulse height. Its rise time is 56 ns with total input capacitance of 810 pF which includes preamplifier, detector and 5-meter-long cable. Considering the rise time and noise characteristics, the most suitable shaping time is 0.1μs. © 2020
引用
收藏
页数:5
相关论文
共 16 条
  • [1] A low-noise charge amplifier with fast rise time and active discharge mechanism
    Bassini, R
    Boiano, C
    Pullia, A
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2436 - 2439
  • [2] A fast low noise charge preamplifier for position sensitive detectors
    Beltrán, D
    Perlas, JA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08) : 3075 - 3079
  • [3] A METHOD FOR THE DETERMINATION OF THE NOISE PARAMETERS IN PREAMPLIFYING SYSTEMS FOR SEMICONDUCTOR RADIATION DETECTORS
    BERTUCCIO, G
    PULLIA, A
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (11) : 3294 - 3298
  • [4] Performance investigation of the pulse and Campbelling modes of a fission chamber using a Poisson pulse train simulation code
    Elter, Z. S.
    Jammes, C.
    Pazsit, I.
    Pal, L.
    Filliatre, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 774 : 60 - 67
  • [5] A fast, compact solution for low noise charge preamplifiers
    Fabris, L
    Madden, NW
    Yaver, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 424 (2-3) : 545 - 551
  • [6] A wide band, low direct current drift, low noise preamplifier for a quadrupole mass spectrometer
    Fan, Kuangang
    Wu, Baojun
    Chen, Renyi
    Liu, Pingchuan
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (02)
  • [7] SUBOPTIMAL FILTERING OF 1/F-NOISE IN DETECTOR CHARGE MEASUREMENTS
    GATTI, E
    MANFREDI, PF
    SAMPIETRO, M
    SPEZIALI, V
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (03) : 467 - 478
  • [8] Geslot B., 2009, 2009 1 INT C ADVANCE, P1, DOI DOI 10.1109/ANIMMA.2009.5503816
  • [9] Method to Calibrate Fission Chambers in Campbelling Mode
    Geslot, Benoit
    Unruh, Troy C.
    Filliatre, Philippe
    Jammes, Christian
    Di Salvo, Jacques
    Breaud, Stephane
    Villard, Jean-Francois
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1377 - 1381
  • [10] Fusion neutron flux monitor for ITER
    Jinwei, Yang
    Qingwei, Yang
    Gongshan, Xiao
    Wei, Zhang
    Xianying, Song
    Xu, Li
    [J]. PLASMA SCIENCE & TECHNOLOGY, 2008, 10 (02) : 141 - 147