Improving the reproducibility of MR-derived left ventricular volume and function measurements with a semi-automatic threshold-based segmentation algorithm

被引:41
作者
Jaspers, Karolien [1 ]
Freling, Hendrik G. [1 ]
van Wijk, Kees [2 ]
Romijn, Elisabeth I. [1 ,3 ]
Greuter, Marcel J. W. [1 ]
Willems, Tineke P. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, NL-9700 RB Groningen, Netherlands
[2] Medis Med Imaging Syst BV, NL-2300 AJ Leiden, Netherlands
[3] Norwegian Univ Sci & Technol, Dept Phys, NO-7491 Trondheim, Norway
关键词
Cardiovascular magnetic resonance imaging; Left ventricle; Function; Trabeculae; Segmentation algorithm; MAGNETIC-RESONANCE; PAPILLARY-MUSCLES; EJECTION FRACTION; TRABECULAE; IMAGES; IMPACT; QUANTIFICATION; NONCOMPACTION; MYOCARDIUM; CINE;
D O I
10.1007/s10554-012-0130-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To validate a novel semi-automatic segmentation algorithm for MR-derived volume and function measurements by comparing it with the standard method of manual contour tracing. The new algorithms excludes papillary muscles and trabeculae from the blood pool, while the manual approach includes these objects in the blood pool. An epicardial contour served as input for both methods. Multiphase 2D steady-state free precession short axis images were acquired in 12 subjects with normal heart function and in a dynamic anthropomorphic heart phantom on a 1.5T MR system. In the heart phantom, manually and semi-automatically measured cardiac parameters were compared to the true end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF). In the subjects, the semi-automatic method was compared to manual contouring in terms of difference in measured EDV, ESV, EF and myocardial volume (MV). For all measures, intra- and inter-observer agreement was determined. In the heart phantom, EDV and ESV were underestimated for both the semi-automatic. As the papillary muscles were excluded from the blood pool with the semi-automatic method, EDV and ESV were approximately 20 ml lower in the patients, whereas EF was approximately 16 % higher. Intra- and inter-observer agreement was overall improved with the semi-automatic method compared to the manual method. Correlation between manual and semi-automatic measurements was high (EDV: R = 0.99, ESV: R = 0.96; EF: R = 0.80, MV: R = 0.99). The semi-automatic method could exclude endoluminal muscular structures from the blood volume with significantly improved intra- and inter-observer variabilities in cardiac function measurements compared to the conventional, manual method, which includes endoluminal structures in the blood volume.
引用
收藏
页码:617 / 623
页数:7
相关论文
共 20 条
  • [1] ISOLATED NONCOMPACTION OF LEFT-VENTRICULAR MYOCARDIUM - A STUDY OF 8 CASES
    CHIN, TK
    PERLOFF, JK
    WILLIAMS, RG
    JUE, K
    MOHRMANN, R
    [J]. CIRCULATION, 1990, 82 (02) : 507 - 513
  • [2] Left ventricle: Automated segmentation by using myocardial effusion threshold reduction and Intravoxel Computation at MR imaging
    Codella, Noel C. F.
    Weinsaft, Jonathan W.
    Cham, Matthew D.
    Janik, Matthew
    Prince, Martin R.
    Wang, Yi
    [J]. RADIOLOGY, 2008, 248 (03) : 1004 - 1012
  • [3] Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography -: Comparison with magnetic resonance imaging
    Dewey, Marc
    Mueller, Mira
    Eddicks, Stephan
    Schnapauff, Dirk
    Teige, Florian
    Rutsch, Wolfgang
    Borges, Adrian C.
    Hamm, Bernd
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) : 2034 - 2044
  • [4] Farneback G., 2002, POLYNOMIAL EXPANSION
  • [5] Left ventricular trabeculae: quantification in different cardiac diseases and impact on left ventricular morphological and functional parameters assessed with cardiac magnetic resonance
    Fernandez-Golfin, Covadonga
    Pachon, Marta
    Corros, Cecilia
    Bustos, Ana
    Cabeza, Beatriz
    Ferreiros, Joaquin
    Perez de Isla, Leopoldo
    Macaya, Carlos
    Zamorano, Jose
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2009, 10 (11) : 827 - 833
  • [6] Experimental validation of an automated edge-detection method for a simultaneous determination of the endocardial and epicardial borders in short-axis cardiac MR images:: Application in normal volunteers
    Furber, A
    Balzer, P
    Cavaro-Ménard, C
    Croué, A
    Da Costa, E
    Lethimonnier, F
    Geslin, P
    Tadéi, A
    Jallet, P
    Le Jeune, JJ
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05): : 1006 - 1014
  • [7] Graves M J, 2000, J Magn Reson Imaging, V12, P232
  • [8] Effects of papillary muscles and trabeculae on left ventricular quantification: increased impact of methodological variability in patients with left ventricular hypertrophy
    Janik, Matthew
    Cham, Matthew D.
    Ross, Michael I.
    Wang, Yi
    Codella, Noel
    Min, James K.
    Prince, Martin R.
    Manoushagian, Shant
    Okin, Peter M.
    Devereux, Richard B.
    Weinsaft, Jonathan W.
    [J]. JOURNAL OF HYPERTENSION, 2008, 26 (08) : 1677 - 1685
  • [9] RELATION OF LEFT-VENTRICULAR MASS AND GEOMETRY TO MORBIDITY AND MORTALITY IN UNCOMPLICATED ESSENTIAL-HYPERTENSION
    KOREN, MJ
    DEVEREUX, RB
    CASALE, PN
    SAVAGE, DD
    LARAGH, JH
    [J]. ANNALS OF INTERNAL MEDICINE, 1991, 114 (05) : 345 - 352
  • [10] Automatic segmentation of the left ventricle cavity and myocardium in MRI data
    Lynch, M
    Ghita, O
    Whelan, PF
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2006, 36 (04) : 389 - 407