Core Biopsy with Curved Needle Technique

被引:12
作者
Singh, Ajay K. [1 ,2 ]
Leeman, Joshua [1 ]
Shankar, Sridhar [1 ]
Ferrucci, Joseph T. [1 ]
机构
[1] Univ Massachusetts, Mem Med Ctr, Dept Radiol, Worcester, MA 01605 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
biopsy gun; core biopsy; CT-guided biopsy; curved needle biopsy; fine-needle aspiration;
D O I
10.2214/AJR.08.1165
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to define the technique and study the feasibility of curved needle biopsy performed with a coaxial core biopsy system. CONCLUSION. Curved core needle biopsy is a simple and feasible technique with a high technical success rate even with suboptimal coaxial needle placement. With the technique, different parts of a focal lesion can be biopsied without manipulation of the coaxial needle. This feature may help in avoiding injury to vital structures.
引用
收藏
页码:1745 / 1750
页数:6
相关论文
共 19 条
[1]   Percutaneous image-guided cutting needle biopsy of the pleura in the diagnosis of malignant mesothelioma [J].
Adams, RF ;
Gray, W ;
Davies, RJO ;
Gleeson, FV .
CHEST, 2001, 120 (06) :1798-1802
[2]   CT-guided lung biopsy: Factors influencing diagnostic yield and complication rate [J].
Anderson, JM ;
Murchison, J ;
Patel, D .
CLINICAL RADIOLOGY, 2003, 58 (10) :791-797
[3]   PREVENTION OF MALIGNANT SEEDING AFTER INVASIVE DIAGNOSTIC PROCEDURES IN PATIENTS WITH PLEURAL MESOTHELIOMA - A RANDOMIZED TRIAL OF LOCAL RADIOTHERAPY [J].
BOUTIN, C ;
REY, F ;
VIALLAT, JR .
CHEST, 1995, 108 (03) :754-758
[4]   ASPIRATION BIOPSY - USE OF A CURVED NEEDLE [J].
CARRASCO, CH ;
WALLACE, S ;
CHARNSANGAVEJ, C .
RADIOLOGY, 1985, 155 (01) :254-254
[5]   Transthoracic needle aspiration biopsy: Variables that affect risk of pneumothorax [J].
Cox, JE ;
Chiles, C ;
McManus, CM ;
Aquino, SL ;
Choplin, RH .
RADIOLOGY, 1999, 212 (01) :165-168
[6]   CT-guided needle biopsy of deep pelvic lesions by extraperitoneal approach through iliopsoas muscle [J].
Gupta, S ;
Madoff, DC ;
Ahrar, K ;
Morello, FA ;
Wallace, MJ ;
Murthy, R ;
Hicks, ME .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 26 (06) :534-538
[7]   Technical innovation - Using a coaxial technique with a curved inner needle for CT-guided fine-needle aspiration biopsy [J].
Gupta, S ;
Ahrar, K ;
Morello, FA ;
Wallace, MJ ;
Madoff, DC ;
Hicks, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (01) :109-112
[8]   CURVED STYLUS FOR REDIRECTION OF THE FINE-NEEDLE GUIDE [J].
HAWKINS, IF ;
CARIDI, JG .
RADIOLOGY, 1984, 151 (02) :530-530
[9]   Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients [J].
Klein, JS ;
Salomon, G ;
Stewart, EA .
RADIOLOGY, 1996, 198 (03) :715-720
[10]   CURVED BIOPSY NEEDLE FOR STEREOTACTIC SURGERY - A TECHNICAL NOTE [J].
LEVY, WJ ;
ORO, JJ .
NEUROSURGERY, 1984, 15 (01) :82-85