Quantitative high contrast X-ray microtomography for dental research

被引:49
|
作者
Davis, Graham R. [1 ]
Evershed, Anthony N. Z. [1 ]
Mills, David [1 ]
机构
[1] Univ London, Inst Dent, London E1 4NS, England
基金
英国工程与自然科学研究理事会;
关键词
Microtomography; Micro-CT; Dead tracts; Mineral concentration; CARIES-REMOVAL; MINERALIZATION; TOMOGRAPHY; EXCAVATION; ACCURACY; MICROCT; TUBE;
D O I
10.1016/j.jdent.2013.01.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: X-ray microtomography (XMT or micro-CT) is a miniaturized version of medical CT and has been used extensively for in vitro dental research. The technique allows three-dimensional analyses of both structure and density (or concentration), the latter requiring some a priori knowledge of composition. The aim of this paper is to demonstrate the capabilities of an XMT scanner specifically designed for dental research, especially that requiring high contrast resolution or accurate mineral concentration quantification. Methods: The MuCAT scanners designed at Queen Mary, University of London, use high dynamic range CCD cameras with time-delay integration readout to provide high quality tomographic images. Accuracy in mineral concentration quantification is achieved using a modelling approach to beam hardening correction with automatic calibration following every scan. Accuracy was tested by measuring the density of a hydroxyapatite disc, and the utility of the high contrast and high accuracy capabilities are demonstrated in three applications from ongoing dental research projects. Results: Quantification accuracy in the hydroxyapatite disc density was better than 1%. In dental applications, slight differences in mineral concentration allowed features such as dead tracts to be visualized and ion transport from a glass-ionomer cement into demineralized dentine to be observed. Conclusion: The improved accuracy and contrast sensitivity, together with the non-destructive nature of XMT in general, facilitates precise studies of dynamic processes in teeth. The ability to differentiate subtle differences in mineral concentration allows dead tracts to be traced in three dimensions, linking external pathology in teeth to reactive processes from the pulp. Clinical significance: The MuCAT scanners have been optimized for quantification of mineral concentration and are particularly useful for in vitro studies of de-and re-mineralization, excavation and other treatment methodologies, and for gaining further insight into tooth morphology and pathology. Results from such studies will inform development of clinical treatment and management. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 50 条
  • [41] Experimental system for X-ray cone-beam microtomography
    Pan, S
    Liou, W
    Shih, A
    Park, MS
    Wang, G
    Newberry, SP
    Kim, H
    Shinozaki, DM
    Cheng, PC
    MICROSCOPY AND MICROANALYSIS, 1998, 4 (01) : 56 - 62
  • [42] X-ray microtomography application in pore space reservoir rock
    Oliveira, M. F. S.
    Lima, I.
    Borghi, L.
    Lopes, R. T.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1376 - 1378
  • [43] High quality 3D imaging of vertebrate microremains using X-ray synchrotron phase contrast microtomography
    Pouech, Joane
    Mazin, Jean-Michel
    Tafforeau, Paul
    COMPTES RENDUS PALEVOL, 2010, 9 (6-7) : 389 - 395
  • [44] Aspects of X-ray microtomography equipment design
    Davis, GR
    Elliott, JC
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 182 - 190
  • [45] Phase retrieval in quantitative x-ray microtomography with a single sample-to-detector distance
    Chen, R. C.
    Xie, H. L.
    Rigon, L.
    Longo, R.
    Castelli, E.
    Xiao, T. Q.
    OPTICS LETTERS, 2011, 36 (09) : 1719 - 1721
  • [46] Quantitative edge illumination x-ray phase contrast tomography
    Hagen, Charlotte K.
    Diemoz, Paul C.
    Endrizzi, Marco
    Rigon, Luigi
    Dreossi, Diego
    Arfelli, Fulvia
    Lopez, Frances C. M.
    Longo, Renata
    Olivo, Alessandro
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [47] Accuracy evaluation of an X-ray microtomography system
    Fernandes, Jaquiel S.
    Appoloni, Carlos R.
    Fernandes, Celso P.
    MICRON, 2016, 85 : 34 - 38
  • [48] A beam hardening correction for X-ray microtomography
    de Paiva, RF
    Lynch, J
    Rosenberg, E
    Bisiaux, M
    NDT & E INTERNATIONAL, 1998, 31 (01) : 17 - 22
  • [49] Investigating biofilm structure using X-ray microtomography and gratings-based phase contrast
    Miller, Erin A.
    Xiao, Xianghui
    Miller, Micah
    Keller, Paul
    White, Timothy A.
    Marshall, Matthew
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [50] Microporosity and polymerization contraction as function of depth in dental resin cements by X-ray computed microtomography
    Gheller, Rafaela
    Burey, Adrieli
    Vicentin, Bruno Luiz Santana
    dos Reis, Paulo Jose
    Appoloni, Carlos Roberto
    Garbelini, Cassia Cilene Dezan
    Hoeppner, Marcio Grama
    MICROSCOPY RESEARCH AND TECHNIQUE, 2020, 83 (06) : 658 - 666