Quantitative high contrast X-ray microtomography for dental research

被引:49
|
作者
Davis, Graham R. [1 ]
Evershed, Anthony N. Z. [1 ]
Mills, David [1 ]
机构
[1] Univ London, Inst Dent, London E1 4NS, England
基金
英国工程与自然科学研究理事会;
关键词
Microtomography; Micro-CT; Dead tracts; Mineral concentration; CARIES-REMOVAL; MINERALIZATION; TOMOGRAPHY; EXCAVATION; ACCURACY; MICROCT; TUBE;
D O I
10.1016/j.jdent.2013.01.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: X-ray microtomography (XMT or micro-CT) is a miniaturized version of medical CT and has been used extensively for in vitro dental research. The technique allows three-dimensional analyses of both structure and density (or concentration), the latter requiring some a priori knowledge of composition. The aim of this paper is to demonstrate the capabilities of an XMT scanner specifically designed for dental research, especially that requiring high contrast resolution or accurate mineral concentration quantification. Methods: The MuCAT scanners designed at Queen Mary, University of London, use high dynamic range CCD cameras with time-delay integration readout to provide high quality tomographic images. Accuracy in mineral concentration quantification is achieved using a modelling approach to beam hardening correction with automatic calibration following every scan. Accuracy was tested by measuring the density of a hydroxyapatite disc, and the utility of the high contrast and high accuracy capabilities are demonstrated in three applications from ongoing dental research projects. Results: Quantification accuracy in the hydroxyapatite disc density was better than 1%. In dental applications, slight differences in mineral concentration allowed features such as dead tracts to be visualized and ion transport from a glass-ionomer cement into demineralized dentine to be observed. Conclusion: The improved accuracy and contrast sensitivity, together with the non-destructive nature of XMT in general, facilitates precise studies of dynamic processes in teeth. The ability to differentiate subtle differences in mineral concentration allows dead tracts to be traced in three dimensions, linking external pathology in teeth to reactive processes from the pulp. Clinical significance: The MuCAT scanners have been optimized for quantification of mineral concentration and are particularly useful for in vitro studies of de-and re-mineralization, excavation and other treatment methodologies, and for gaining further insight into tooth morphology and pathology. Results from such studies will inform development of clinical treatment and management. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 50 条
  • [1] High-contrast x-ray microtomography in dental research
    Davis, Graham
    Mills, David
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [2] Quantitative X-ray microtomography with a conventional source
    Davis, Graham
    Evershed, Anthony
    Elliott, James
    Mills, David
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [3] Artefacts in X-ray microtomography of materials
    Davis, G. R.
    Elliott, J. C.
    MATERIALS SCIENCE AND TECHNOLOGY, 2006, 22 (09) : 1011 - 1018
  • [4] X-ray microtomography, past and present
    Elliott, J. C.
    Davis, G. R.
    Dover, S. D.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [5] The possibility of phase-contrast X-ray microtomography
    Momose, A
    Hirano, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 : 625 - 629
  • [6] Fast method for the estimation of the absorbed dose in X-ray microtomography
    De Muynck, Amelie
    Bonte, Stijn
    Dhaene, Jelle
    Dierick, Manuel
    Bacher, Klaus
    Van Hoorebeke, Luc
    Boone, Matthieu N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 452 : 40 - 47
  • [7] X-ray microtomography in biology
    Mizutani, Ryuta
    Suzuki, Yoshio
    MICRON, 2012, 43 (2-3) : 104 - 115
  • [8] Scintillator to CCD coupling in X-ray microtomography
    Davis, Graham R.
    Elliott, James C.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [9] X-ray microtomography of plastics and composite materials
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 274 - 281
  • [10] Desk-top x-ray microtomography
    Sasov, A
    Ceulemans, T
    Van Dyck, D
    METROLOGY-BASED CONTROL FOR MICRO-MANUFACTURING, 2001, 4275 : 147 - 154