Protective Layer Development for Enhancing Stability and Drug-Delivery Capabilities of DES Surface-Crystallized Coatings

被引:11
作者
Farah, Shady [1 ,2 ,3 ,4 ]
机构
[1] Hebrew Univ Jerusalem, Inst Drug Res, Sch Pharm, Fac Med,Ctr Nanosci & Nanotechnol, IL-91120 Jerusalem, Israel
[2] Hebrew Univ Jerusalem, Alex Grass Ctr Drug Design & Synth, IL-91120 Jerusalem, Israel
[3] MIT, David H Koch Inst Integrat Canc Res, 500 Main St, Cambridge, MA 02139 USA
[4] MIT, Dept Chem Engn, 77 Massachusetts Ave, Cambridge, MA 02139 USA
基金
以色列科学基金会;
关键词
bioactive surface coating; drug eluting stents; sequential release; rapamycin; crystallization; metallic surfaces; controlled multilayer-release; hyaluronic acid; ELUTING STENTS; THERMAL-STABILITY; CORONARY STENT; RAPAMYCIN; SIROLIMUS; POLYMER; DURABILITY; RESTENOSIS;
D O I
10.1021/acsami.7b18733
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Carrier-free drug-eluting stents (DES)-based crystalline coatings are gaining prominence because of their function, skipping many limitations and clinical complications of the currently marketed DES. However, their usage has been humbled by inflexibility of the crystalline coating and limited mechanical and physical properties. This study reports for the first time the development of a protective top coating for enhancing the merits and delivery capabilities of the crystalline coating. Flexible and water-soluble polysaccharide top coating was developed and applied onto rapamycin (RM) crystalline carpet. The top coating prevented crystalline coating delamination during stent crimping and expansion without affecting its release profile. Crystalline coating strata and its interfaces with the metallic substrate and top coating were fully studied and characterized. The crystalline top-coated stents showed significant physical, mechanical, and chemical stability enhancement with similar to 2% RM degradation after 1 year under different storage conditions. Biocompatibility study of the top-coated stents implanted subcutaneously for 1 month into SD rats did not provoke any safety concerns. Incorporating RM into the top coating to develop a bioactive protective coating for multilayer release purposes was also investigated. The developed protective coating had wide applicability and may be further implemented for various drugs and implantable medical devices.
引用
收藏
页码:9010 / 9022
页数:13
相关论文
共 61 条
[51]   X-RAY CRYSTAL-STRUCTURE OF RAPAMYCIN, C51H79NO13 [J].
SWINDELLS, DCN ;
WHITE, PS ;
FINDLAY, JA .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1978, 56 (18) :2491-2492
[52]   Polymer-Free Biolimus A9-Coated Stent Demonstrates More Sustained Intimal Inhibition, Improved Healing, and Reduced Inflammation Compared With a Polymer-Coated Sirolimus-Eluting Cypher Stent in a Porcine Model [J].
Tada, Norio ;
Virmani, Renu ;
Grant, Gordon ;
Bartlett, Lauren ;
Black, Alexander ;
Clavijo, Claudia ;
Christians, Uwe ;
Betts, Ron ;
Savage, Doug ;
Su, Shih-Horng ;
Shulze, John ;
Kar, Saibal .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (02) :174-183
[53]   Local vascular toxicokinetics of stent-based drug delivery [J].
Tesfamariam, Belay .
TOXICOLOGY LETTERS, 2007, 168 (02) :93-102
[54]   Stent elution rate determines drug deposition and receptor-mediated effects [J].
Tzafriri, Abraham R. ;
Groothuis, Adam ;
Price, G. Sylvester ;
Edelman, Elazer R. .
JOURNAL OF CONTROLLED RELEASE, 2012, 161 (03) :918-926
[55]  
Unger Felix, 2007, Interact Cardiovasc Thorac Surg, V6, P813, DOI 10.1510/icvts.2007.161471
[56]   Drug-eluting stents: trading restenosis for thrombosis? [J].
Van Belle, E. ;
Susen, S. ;
Jude, B. ;
Bertrand, M. E. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2007, 5 :238-245
[57]  
Vorpahl M, 2009, Minerva Cardioangiol, V57, P621
[58]   Self-assembled Biodegradable Nanoparticles and Polysaccharides as Biomimetic ECM Nanostructures for the Synergistic effect of RGD and BMP-2 on Bone Formation [J].
Wang, Zhenming ;
Dong, Li ;
Han, Lu ;
Wang, Kefeng ;
Lu, Xiong ;
Fang, Liming ;
Qu, Shuxin ;
Chan, Chun Wai .
SCIENTIFIC REPORTS, 2016, 6
[59]  
WHO, 2006, QAS06179 WHO
[60]   Late coronary stent thrombosis [J].
Windecker, Stephan ;
Meier, Bernhard .
CIRCULATION, 2007, 116 (17) :1952-1965