Magnetic navigation in AV nodal re-entrant tachycardia study: early results of ablation with one- and three-magnet catheters

被引:37
作者
Thornton, A. S. [1 ]
Janse, P. [1 ]
Theuns, D. A. M. J. [1 ]
Scholten, M. F. [1 ]
Jordaens, L. J. [1 ]
机构
[1] Erasmus MC, Ctr Thorax, Dept Cardiol, Clin Electrophysiol Unit, NL-3015 GD Rotterdam, Netherlands
来源
EUROPACE | 2006年 / 8卷 / 04期
关键词
arrhythmias; AV nodal re-entrant tachycardia; catheter ablation; magnetic navigation; stereotactic therapy;
D O I
10.1093/europace/euj026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Steering soft, flexible catheters using an external magnetic field could have advantages for heart catheterization, especially for therapy of tachyarrhythmias. Our aims were to assess the feasibility of magnetic navigation to Koch's triangle and reliable ablation of atrioventricular nodal re-entry tachycardia (AVNRT) with a magnetic catheter. Methods and results Consecutive patients with AVNRT were mapped and ablated with a magnetically enabled catheter (Helios I or II), with, respectively, one and three magnets at the tip. The catheter was remotely advanced with the Cardiodrive (TM) system and orientated with the Navigant (TM) control system. After initial positioning with the external magnets, adjustment was made in 5 degrees steps. Success rates, procedure, and fluoroscopy times were analysed, and compared with a local contemporary series of conventional AVNRT ablations. Magnetic navigation was feasible in all 20 patients. Targets were easily reached. Catheters remained stable in position during accelerated junctional rhythms. Ablation was successful in 18/20 procedures (90%). No significant complications occurred. Median patient fluoroscopy time was 12 min, median physician fluoroscopy time was 4 min. Fluoroscopy times tended to be shorter than that in the conventionally treated group. Procedure duration decreased significantly over time, median procedure time was similar to that in the conventional group. Conclusion AVNRT can be successfully mapped and ablated using magnetic navigation. A learning curve was evident, unrelated to catheter type, but to increasing operator experience. Physician radiation times were one-third of patient times. No complications occurred. Procedure time is comparable with that of conventional ablation.
引用
收藏
页码:225 / 230
页数:6
相关论文
共 11 条
[1]   Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction - Final results of a prospective, multicenter clinical trial [J].
Calkins, H ;
Yong, P ;
Miller, JM ;
Olshansky, B ;
Carlson, M ;
Saul, JP ;
Huang, SKS ;
Liem, LB ;
Klein, LS ;
Moser, SA ;
Bloch, DA ;
Gillette, P ;
Prystowsky, E .
CIRCULATION, 1999, 99 (02) :262-270
[2]   Initial experience with remote catheter ablation using a novel magnetic navigation system -: Magnetic remote catheter ablation [J].
Ernst, S ;
Ouyang, FF ;
Linder, C ;
Hertting, K ;
Stahl, F ;
Chun, J ;
Hachiya, H ;
Bänsch, D ;
Antz, M ;
Kuck, KH .
CIRCULATION, 2004, 109 (12) :1472-1475
[3]   Modulation of the slow pathway in the presence of a persistent left superior caval vein using the novel magnetic navigation system Niobe [J].
Ernst, S ;
Ouyang, F ;
Linder, C ;
Hertting, K ;
Stahl, F ;
Chun, J ;
Hachiya, H ;
Krumsdorf, U ;
Antz, M ;
Kuck, KH .
EUROPACE, 2004, 6 (01) :10-14
[4]   Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation [J].
Faddis, MN ;
Blume, W ;
Finney, J ;
Hall, A ;
Rauch, J ;
Sell, J ;
Bae, KT ;
Talcott, M ;
Lindsay, B .
CIRCULATION, 2002, 106 (23) :2980-2985
[5]   Magnetic guidance system for cardiac electrophysiology - A prospective trial of safety and efficacy in humans [J].
Faddis, MN ;
Chen, J ;
Osborn, J ;
Talcott, M ;
Cain, ME ;
Lindsay, BD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) :1952-1958
[6]   THE MULTICENTER-EUROPEAN-RADIOFREQUENCY-SURVEY (MERFS) - COMPLICATIONS OF RADIOFREQUENCY CATHETER ABLATION OF ARRHYTHMIAS [J].
HINDRICKS, G ;
ALIOT, E ;
ALMENDRAL, JM ;
AMLIE, J ;
ARLOTTI, M ;
BARNAY, C ;
BASHIR, Y ;
BERGFELDT, L ;
BLANC, J ;
HIMBERT, J ;
THOMSEN, PEB ;
BLOMSTROMLUNDQVIST, C ;
BREMBILLAPERROT, B ;
BRUGADA, P ;
BRUGADA, J ;
COWAN, JC ;
CAUCHEMEZ, B ;
CLEMENTY, J ;
COBBE, S ;
CRITELLI, G ;
CRIJNS, H ;
DAUBERT, JC ;
DESOUSA, J ;
DJIANE, P ;
DONZEAU, JP ;
DUCKECK, W ;
EDWARDSSON, N ;
FARRE, J ;
COSNAY, P ;
FONTAINE, G ;
FROMER, M ;
GOICOLEA, A ;
GONSKA, BD ;
GROLLEAURAOUX, R ;
HAISSAGUERRE, M ;
HAVERKAMP, W ;
HERMIDA, JS ;
HIEF, C ;
HOPP, HW ;
HOFFMAN, E ;
HUIKURI, H ;
JORDAENS, L ;
KALUSCHE, D ;
KUHLKAMP, V ;
LAUCEVICIUS, A ;
LAVERGNE, T ;
MANZ, M ;
MOLLER, M ;
MONT, L ;
NATHAN, AW .
EUROPEAN HEART JOURNAL, 1993, 14 (12) :1644-1653
[7]   Use of intracardiac echocardiography in interventional electrophysiology [J].
Kalman, JM ;
Olgin, JE ;
Karch, MR ;
Lesh, MD .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (09) :2248-2262
[8]   CRAVT: a prospective, randomized study comparing transvenous cryothermal and radiofrequency ablation in atrioventricular nodal re-entrant tachycardia [J].
Kimman, GP ;
Theuns, DAMJ ;
Szili-Torok, T ;
Scholten, MF ;
Res, JC ;
Jordaens, LJ .
EUROPEAN HEART JOURNAL, 2004, 25 (24) :2232-2237
[9]   Slow pathway catheter ablation of atrioventricular nodal re-entrant tachycardia guided by electroanatomical mapping: a randomized comparison to the conventional approach [J].
Kopelman, HA ;
Prater, SP ;
Tondato, F ;
Chronos, NAF ;
Peters, NS .
EUROPACE, 2003, 5 (02) :171-174
[10]  
Skanes AC, 2000, CIRCULATION, V102, P2856