Systematic review and meta-analysis of valve-in-valve transcatheter aortic valve replacement in patients with failed bioprosthetic aortic valves

被引:17
作者
Mahmoud, Ahmed N. [1 ]
Gad, Mohamed M. [2 ]
Elgendy, Islam Y. [3 ,4 ]
Mahmoud, Ahmad A. [5 ]
Taha, Yasmeen [5 ]
Elgendy, Akram Y. [6 ]
Ahuja, Keerat R. [2 ]
Saad, Anas M. [2 ]
Simonato, Matheus [7 ]
McCabe, James M. [1 ]
Reisman, Mark [1 ]
Kapadia, Samir R. [2 ]
Dvir, Danny [1 ]
机构
[1] Univ Washington, Div Cardiol, 1410 NE Campus Pkwy, Seattle, WA 98195 USA
[2] Cleveland Clin, Heart & Vasc Inst, Cleveland, OH 44106 USA
[3] Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
[4] Harvard Med Sch, Boston, MA 02115 USA
[5] Univ Florida, Dept Med, Gainesville, FL USA
[6] Univ Florida, Div Cardiol, Gainesville, FL USA
[7] Univ Fed Sao Paulo, Escola Paulista Med, Sao Paulo, Brazil
关键词
aortic stenosis; clinical research; TAVI; valve-in-valve; LONG-TERM DURABILITY; IMPLANTATION; OUTCOMES; STENTLESS; RISK; SURGERY; IMPACT; TAVR;
D O I
10.4244/EIJ-D-19-00928
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The aim of this meta-analysis was to evaluate the evidence regarding the rates of procedural success and the incidence of adverse outcomes following valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) in patients with failed bioprosthetic aortic valves. Methods and results: A systematic search of major electronic databases was conducted for studies relevant to patients with failed bioprosthetic aortic valves undergoing VIV-TAVR. The primary outcome was procedural success. A total of 5,553 patients from 24 studies were included. The mean Society of Thoracic Surgeons (STS) score was 7.84 +/- 5.14. The procedural success rate was high (97%, 95% confidence interval [CI]: 94-98%). At 30 days, all-cause mortality was 5% (95% CI: 3-6%), stroke 2% (95% CI: 1-2%), myocardial infarction 1% (95% CI: 1-2%), permanent pacemaker placement 6% (95% CI: 5-8%), and aortic regurgitation 7% (95% CI: 5-10%). At one year, the incidence of all-cause mortality was 12% (95% CI: 10-14%), stroke 3% (95% CI: 2-4%), myocardial infarction 1% (95% CI: 0-2%), and permanent pacemaker placement 7% (95% CI: 5-11%). At three years, the incidence of all-cause mortality was 29% (95% CI: 25-34%) and stroke 6% (95% CI: 5-9%). Conclusions: VIV-TAVR appears to be associated with high procedural success rates and low adverse outcomes during the short-term and midterm follow-up period.
引用
收藏
页码:539 / +
页数:26
相关论文
共 45 条
[1]   Impact of Hospital Transcatheter Aortic Valve Replacement Volume on Incidence and Outcomes of Cardiac Tamponade [J].
Ahuja, Keerat Rai ;
Gad, Mohamed M. ;
Bazarbashi, Najdat ;
Karrthik, Antonette K. ;
Raheja, Hitesh ;
Goel, Sunny ;
Reed, Grant ;
Puri, Rishi ;
Krishnaswamy, Amar ;
Kapadia, Samir R. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) :2232-2234
[2]  
[Anonymous], 2007, R News
[3]   Transcatheter aortic valve-in-valve implantation for failed surgical bioprosthetic valves. A minimalist approach without contrast aortography or echocardiographic guidance [J].
Attinger-Toller, Adrian ;
Htun, Nay M. ;
Murdoch, Dale ;
Perlman, Gidon Y. ;
Alenezi, Abdullah ;
Sathananthan, Janarthanan ;
Blanke, Philipp ;
Leipsic, Jonathon ;
Thompson, Christopher ;
Ye, Jian ;
Cheung, Anson ;
Wood, David ;
Webb, John G. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (01) :45-53
[4]   The utilization of single versus double Perclose devices for transfemoral aortic valve replacement access site closure: Insights from Cleveland Clinic Aortic Valve Center [J].
Bazarbashi, Najdat ;
Ahuja, Keerat ;
Gad, Mohamed M. ;
Sammour, Yasser M. ;
Kaur, Manpreet ;
Karrthik, Antonette ;
Saad, Anas M. ;
Khubber, Shameer ;
Dhaliwal, Kamalpreet ;
Mick, Stephanie L. ;
Navia, Jose L. ;
Puri, Rishi ;
Reed, Grant W. ;
Krishnaswamy, Amar ;
Kapadia, Samir R. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (02) :442-447
[5]   Long-Term Durability of Transcatheter Aortic Valve Prostheses [J].
Blackman, Daniel J. ;
Saraf, Smriti ;
MacCarthy, Philip A. ;
Myat, Aung ;
Anderson, Simon G. ;
Malkin, Christopher J. ;
Cunnington, Michael S. ;
Somers, Kathryn ;
Brennan, Paul ;
Manoharan, Ganesh ;
Parker, Jessica ;
Aldalati, Omar ;
Brecker, Stephen J. ;
Dowling, Cameron ;
Hoole, Stephen P. ;
Dorman, Stephen ;
Mullen, Michael ;
Kennon, Simon ;
Jerrum, Melanie ;
Chandrala, Pavan ;
Roberts, David H. ;
Tay, Justin ;
Doshi, Sagar N. ;
Ludman, Peter F. ;
Fairbairn, Timothy A. ;
Crowe, Joanne ;
Levy, Richard D. ;
Banning, Adrian P. ;
Ruparelia, Neil ;
Spence, Mark S. ;
Hildick-Smith, David .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (05) :537-545
[6]   Long-Term Outcomes After Transcatheter Aortic Valve-in-Valve Replacement [J].
Campos Guimaraes, Leonardo de Freitas ;
Urena, Marina ;
Wijeysundera, Harindra C. ;
Munoz-Garcia, Antonio ;
Serra, Vicenc ;
Benitez, Luis M. ;
Auffret, Vincent ;
Cheema, Asim N. ;
Amat-Santos, Ignacio J. ;
Fisher, Quentin ;
Himbert, Dominique ;
Garcia del Blanco, Bruno ;
Dager, Antonio ;
Le Breton, Herve ;
Paradis, Jean-Michel ;
Dumont, Eric ;
Pibarot, Philippe ;
Rodes-Cabau, Josep .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (09)
[7]   Outcomes of Transcatheter Aortic Valve Replacement in Mixed Aortic Valve Disease [J].
Chahine, Johnny ;
Kadri, Amer N. ;
Gajulapalli, Rama D. ;
Krishnaswamy, Amar ;
Mick, Stephanie ;
Perez, Oscar ;
Lak, Hassan ;
Nair, Raunak M. ;
Montane, Bryce ;
Tak, James ;
Tuzcu, E. Murat ;
Griffin, Brian ;
Svensson, Lars G. ;
Harb, Serge C. ;
Kapadia, Samir R. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (22) :2299-2306
[8]   A comparison of valve-in-valve transcatheter aortic valve replacement in failed stentless versus stented surgical bioprosthetic aortic valves [J].
Choi, Charles H. ;
Cheng, Vivian ;
Malaver, Diego ;
Kon, Neal ;
Kincaid, Edward H. ;
Gandhi, Sanjay K. ;
Applegate, Robert J. ;
Zhao, David X. M. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (06) :1106-1115
[9]   Transcatheter valve-in-valve therapy using 6 different devices in 4 anatomic positions: Clinical outcomes and technical considerations [J].
Conradi, Lenard ;
Silaschi, Miriam ;
Seiffert, Moritz ;
Lubos, Edith ;
Blankenberg, Stefan ;
Reichenspurner, Hermann ;
Schaefer, Ulrich ;
Treede, Hendrik .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (06) :1557-+
[10]   Durability and Clinical Outcomes of Transcatheter Aortic Valve Replacement for Failed Surgical Bioprostheses [J].
Dauerman, Harold L. ;
Deeb, G. Michael ;
O'Hair, Daniel P. ;
Waksman, Ron ;
Yakubov, Steven J. ;
Kleiman, Neal S. ;
Chetcuti, Stanley J. ;
Hermiller, James B. ;
Bajwa, Tanvir ;
Khabbaz, Kamal ;
de Marchena, Eduardo ;
Salerno, Tomas ;
Dries-Devlin, Jessica L. ;
Li, Shuzhen ;
Popma, Jeffrey J. ;
Reardon, Michael J. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (10)