Frequency and causes of implantable cardioverter-defibrillator therapies: Is device therapy proarrhythmic?

被引:172
作者
Germano, JJ [1 ]
Reynolds, M [1 ]
Essebag, V [1 ]
Josephson, ME [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Harvard Thorndike Electrophysiol Inst, Div Cardiovasc, Boston, MA 02215 USA
基金
加拿大健康研究院;
关键词
D O I
10.1016/j.amjcard.2005.11.048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implantable cardioverter-defibrillator (ICD) shocks diminish patients' quality of life, increase health care resource utilization, and may lead to other adverse sequelae. Better understanding of the factors that lead to ICD therapies, and better strategies to avoid unnecessary therapies, are needed to optimize patient outcomes. Data from major randomized clinical trials involving the use of ICDs and cardiac resynchronization therapydefibrillator devices were reviewed to determine control group mortality rates, control group sudden death rates, and the frequency of appropriate and inappropriate ICD therapies. In all studies that classified deaths, appropriate ICD therapies outnumbered control group sudden cardiac deaths by a factor of 2 to 3. Some of these episodes can be explained by device programming, by the treatment of potentially unsustained tachycardias, and by errors of episode classification. Another underexplored possibility is that device therapy is proarrhythmic. Reasons for frequent therapies and methods to prevent them are discussed, as well as the notion of device proarrhythmia and the potentially detrimental effects of ICD shocks. These issues clearly affect the overall benefit of device therapy and have important implications for patient management and health care delivery. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1255 / 1261
页数:7
相关论文
共 50 条
[1]  
ALKHATIB S, 2004, CIRCULATION, V110, P111
[2]   The 1+1 trial -: A prospective trial of a dual- versus a single-chamber implantable defibrillator in patients with slow ventricular tachycardias [J].
Bänsch, D ;
Steffgen, F ;
Grönefeld, G ;
Wolpert, C ;
Böcker, D ;
Mletzko, RU ;
Schöls, W ;
Seidl, K ;
Piel, M ;
Ouyang, F ;
Hohnloser, SH ;
Kuck, KH .
CIRCULATION, 2004, 110 (09) :1022-1029
[3]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[4]   Prophylactic use of implanted cardiac defibrillators in patients at high risk for ventricular arrhythmias after coronary-artery bypass graft surgery [J].
Bigger, JT .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 337 (22) :1569-1575
[5]   Potential benefit from implantable cardioverter-defibrillator therapy in patients with and without heart failure [J].
Böcker, D ;
Bänsch, D ;
Heinecke, A ;
Weber, M ;
Brunn, J ;
Hammel, D ;
Borggrefe, M ;
Breithardt, G ;
Block, P .
CIRCULATION, 1998, 98 (16) :1636-1643
[6]   COMPARISON OF FREQUENCY OF AGGRAVATION OF VENTRICULAR TACHYARRHYTHMIAS AFTER IMPLANTATION OF AUTOMATIC DEFIBRILLATORS USING EPICARDIAL VERSUS NONTHORACOTOMY LEAD SYSTEMS [J].
BOCKER, D ;
BLOCK, M ;
ISBRUCH, F ;
WIETHOLT, D ;
HAMMEL, D ;
SCHELD, HH ;
BORGGREFE, M ;
BREITHARDT, G .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (12) :1064-1068
[7]   Cardioverter-defibrillator oversensing due to double counting of ventricular tachycardia electrograms [J].
Boriani, G ;
Biffi, M ;
Frabetti, L ;
Parlapiano, M ;
Galli, R ;
Branzi, A ;
Magnani, B .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1998, 66 (01) :91-95
[8]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[9]   A randomized study of the prevention of sudden death in patients with coronary artery disease [J].
Buxton, AE ;
Lee, KL ;
Fisher, JD ;
Josephson, ME ;
Prystowsky, EN ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) :1882-1890
[10]   Electrophysiologic testing to identify patients with coronary artery disease who are at risk for sudden death [J].
Buxton, AE ;
Lee, KL ;
DiCarlo, L ;
Gold, MR ;
Greer, GS ;
Prystowsky, EN ;
O'Toole, MF ;
Tang, A ;
Fisher, JD ;
Coromilas, J ;
Talajic, M ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (26) :1937-1945