Universal pulses: A new concept for calibration-free parallel transmission

被引:123
作者
Gras, Vincent [1 ]
Vignaud, Alexandre [1 ]
Amadon, Alexis [1 ]
Le Bihan, Denis [1 ]
Boulant, Nicolas [1 ]
机构
[1] CEA, NeuroSpin, DSV, Bat 145, F-91191 Gif Sur Yvette, France
基金
欧洲研究理事会;
关键词
parallel transmission; ultra-high field; plug and play; RF pulse design; LEAST-SQUARES OPTIMIZATION; VIRTUAL OBSERVATION POINTS; REDUCED B-1 INHOMOGENEITY; HIGH-FIELD; RF PULSES; POWER CONSTRAINTS; 8; CHANNELS; TESLA; DESIGN; EXCITATION;
D O I
10.1002/mrm.26148
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeA calibration-free parallel transmission method is investigated to mitigate the radiofrequency (RF) field inhomogeneity problem in brain imaging at 7 Tesla (T). Theory and MethodsSix volunteers were scanned to build a representative database of RF and static field maps at 7T. Small-tip-angle and inversion pulses were designed with joint k(T)-points trajectory optimization to work robustly on all six subjects. The returned universal pulses were then inserted in an MPRAGE sequence implemented on six additional volunteers without further field measurements and pulse optimizations. Similar acquisitions were performed in the circularly polarized mode and with subject-based optimizations for comparison. Performance of the different approaches was evaluated by means of image analysis and computation of the flip angle normalized root mean square errors (NRMSE). ResultsFor both the excitation and inversion, the universal pulses (NRMSE approximate to 11%) outperformed the circularly polarized (NRMSE approximate to 28%) and RF shim modes (NRMSE approximate to 20%) across all volunteers and returned slightly worse results than for subject-based optimized pulses (NRMSE approximate to 7%). ConclusionRF pulses can be designed to robustly mitigate the RF field inhomogeneity problem over a population class. This appears as a first step toward another plug and play parallel transmission solution where the pulse design can be done offline and without measuring subject-specific field maps. Magn Reson Med 77:635-643, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:635 / 643
页数:9
相关论文
共 40 条
[1]   Transmit and receive transmission line arrays for 7 tesla parallel imaging [J].
Adriany, G ;
Van de Moortele, PF ;
Wiesinger, F ;
Moeller, S ;
Strupp, JP ;
Andersen, P ;
Snyder, C ;
Zhang, XL ;
Chen, W ;
Pruessmann, KP ;
Boesiger, P ;
Vaughan, T ;
Ugurbil, K .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) :434-445
[2]  
Amadon A., 2015, P 23 ANN M ISMRM TOR
[3]  
[Anonymous], 2010, MED ELECT EQUIPMEN 2, V603, P2
[4]   Unified segmentation [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2005, 26 (03) :839-851
[5]   Strongly modulating pulses for counteracting RF inhomogeneity at high fields [J].
Boulant, N. ;
Le Bihan, D. ;
Amadon, A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :701-708
[6]   Direct Control of the Temperature Rise in Parallel Transmission by Means of Temperature Virtual Observation Points: Simulations at 10.5 Tesla [J].
Boulant, Nicolas ;
Wu, Xiaoping ;
Adriany, Gregor ;
Schmitter, Sebastian ;
Ugurbil, Kamil ;
Van de Moortele, Pierre-Francois .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) :249-256
[7]   B1+ Interferometry for the Calibration of RF Transmitter Arrays [J].
Brunner, David O. ;
Pruessmann, Klaas P. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) :1480-1488
[8]   Parallel-transmission-enabled magnetization-prepared rapid gradient-echo T1-weighted imaging of the human brain at 7 T [J].
Cloos, M. A. ;
Boulant, N. ;
Luong, M. ;
Ferrand, G. ;
Giacomini, E. ;
Hang, M. -F. ;
Wiggins, C. J. ;
Le Bihan, D. ;
Amadon, A. .
NEUROIMAGE, 2012, 62 (03) :2140-2150
[9]   kT-points: Short three-dimensional tailored RF pulses for flip-angle homogenization over an extended volume [J].
Cloos, M. A. ;
Boulant, N. ;
Luong, M. ;
Ferrand, G. ;
Giacomini, E. ;
Le Bihan, D. ;
Amadon, A. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) :72-80
[10]  
Cloos M.A., 2022, P JOINT ANN M ISMRM