Dose-volume histogram evaluation scheme for beam orientations in intensity-modulated radiation therapy

被引:0
|
作者
Azizi-Sultan, Ahmad-Saher [1 ]
机构
[1] Taibah Univ, Dept Math, Medina Munawarah, Saudi Arabia
来源
COMPUTATIONAL & APPLIED MATHEMATICS | 2018年 / 37卷 / 01期
关键词
Dose-volume histogram; Intensity-modulated radiation therapy; Beam orientations in IMRT; Beam selection in IMRT; OPTIMIZATION; IMRT; RADIOTHERAPY; ALGORITHM; SELECTION; MODEL;
D O I
10.1007/s40314-016-0341-9
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Beam orientations in intensity-modulated radiation therapy (IMRT) is an important, but difficult NP-hard optimization problem. A considerable part of this difficulty is due to the essential prerequisite of defining, appropriately, counter-intuitive criteria for a mathematical plan evaluation that coincides with the clinical judgment of the considered plan. Moreover, the quality of beam directions depends heavily on their intensities. Usually a stochastic selector is utilized for optimizing beam orientations, and the intensities are thus calculated many thousands of times, each time for a different selection of beam directions, resulting in excessive time complexity. Therefore, selecting an appropriate set of beam directions in IMRT is still a time-consuming manual trial-and-error search procedure that depends on intuition and empirical knowledge. To overcome these difficulties, this work utilizes the concept of dose-volume histogram (DVH), which is one of the main recognized quantitative measurement tools used for plan judgment, and presents a DVH evaluation scheme that parallelizes plan evaluation with clinical plan judgment. This scheme is then utilized to optimize the intensities of each individual beam, enabling it to be represented by its DVHs, produced for the different irradiated volumes. Finally, an evolutionary algorithm is employed to search for the best combination of those DVHs reflecting the clinical optimal. The presented methods have been applied to three real clinical examples. In comparison to the standard equally spaced beam plans, improvements were reported in all three cases. In comparison with the greedy algorithm, improvements were reported in those examples requiring more than five beam directions.
引用
收藏
页码:191 / 204
页数:14
相关论文
共 50 条
  • [41] Intensity-modulated radiation therapy
    不详
    CURRENT PROBLEMS IN CANCER, 2004, 28 (02) : 47 - 84
  • [42] Intensity-modulated radiation therapy
    Carpini, DD
    HEALTH PHYSICS, 2001, 81 (04): : 469 - 469
  • [43] Intensity-modulated radiation therapy
    Lee, N. Y.
    Terezakis, S. A.
    JOURNAL OF SURGICAL ONCOLOGY, 2008, 97 (08) : 691 - 696
  • [44] Incorporating dose-volume histogram parameters of swallowing organs at risk in a videofluoroscopy-based predictive model of radiation-induced dysphagia after head and neck cancer intensity-modulated radiation therapy
    Ursino, Stefano
    Giuliano, Alessia
    Di Martino, Fabio
    Cocuzza, Paola
    Molinari, Alessandro
    Stefanelli, Antonio
    Giusti, Patrizia
    Aringhieri, Giacomo
    Morganti, Riccardo
    Neri, Emanuele
    Traino, Claudio
    Paiar, Fabiola
    STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (03) : 209 - 218
  • [45] Predictors of Mastoiditis after Intensity-Modulated Radiotherapy in Nasopharyngeal Carcinoma: A Dose-Volume Analysis
    Yao, Ji-Jin
    Zhou, Guan-Qun
    Jin, Ya-Nan
    Zhang, Wang-Jian
    Lin, Li
    Yu, Xiao-Li
    Shao, Jian-Yong
    Ma, Jun
    Sun, Ying
    JOURNAL OF CANCER, 2016, 7 (03): : 276 - 282
  • [46] Sparsity constrained split feasibility for dose-volume constraints in inverse planning of intensity-modulated photon or proton therapy
    Penfold, Scott
    Zalas, Rafal
    Casiraghi, Margherita
    Brooke, Mark
    Censor, Yair
    Schulte, Reinhard
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09): : 3599 - 3618
  • [47] Comparison of Simultaneous Integrated Boost Intensity-Modulated Radiation Therapy and Standard Dose with Intensity-Modulated Radiation Therapy in the Treatment of Esophageal Carcinoma
    Bai, W.
    Zhang, R.
    Qiao, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E559 - E559
  • [48] Use of benchmark dose-volume histograms for selection of the optimal technique between three-dimensional conformal radiation therapy and intensity-modulated radiation therapy in prostate cancer
    Luo, Chunhui
    Yang, Claus Chunli
    Narayan, Samir
    Stern, Robin L.
    Perks, Julian
    Goldberg, Zelanna
    Ryu, Janice
    Purdy, James A.
    Vijayakumar, Srinivasan
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (04): : 1253 - 1262
  • [49] Role of beam orientation optimization in intensity-modulated radiation therapy
    Pugachev, A
    Li, JG
    Boyer, AL
    Hancock, SL
    Le, QT
    Donaldson, SS
    Xing, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (02): : 551 - 560
  • [50] Decoding the Beam Complexity in Intensity-Modulated Radiation Therapy Plans
    Du, W.
    Cho, S.
    Zhang, X.
    Hoffman, K.
    Kudchadker, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 305 - 305