Common-mode voltage;
medium-voltage ac drives;
multilevel inverters;
optimal pulsewidth modulation (PWM);
total harmonic distortion (THD);
HARMONIC ELIMINATION;
GENERALIZED TECHNIQUES;
THYRISTOR INVERTERS;
VOLTAGE CONTROL;
TOPOLOGIES;
CONVERTER;
D O I:
10.1109/TIA.2012.2210016
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
Operating a dual three-level inverter system from a single dc link circuit is an economic solution for generating five-level output voltage waveforms and to double the output power compared to a single three-level inverter. Such an inverter system is used for feeding a drive motor with open stator windings. Amechanism is then required to reduce the common-mode voltage components of the motor voltages. This paper describes an offline optimization method that minimizes both the harmonic distortion of the motor currents and the common-mode voltage components. The optimization permits reduction of the switching frequency to a very low value of 200 Hz without compromising the harmonic distortion. High performance operation of the drive system at low switching frequency is experimentally demonstrated.