Microincision multifocal intraocular lens with and without a capsular tension ring -: Optical quality and clinical outcomes

被引:37
作者
Alio, Jorge L. [1 ,3 ]
Elkady, Bassam [2 ]
Ortiz, Dolores
Bernabeu, Gonzalo
机构
[1] Vissum Inst Oftalmol Alicante, Res Dev & Innovat Dept, Alicante 03016, Spain
[2] Ain Shams Univ, Cairo, Egypt
[3] Miguel Hernandez Univ, Alicante, Spain
关键词
D O I
10.1016/j.jcrs.2008.05.042
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the effect of a capsular tension ring (CTR) on the visual, refractive, and intraocular optical quality of a multifocal intraocular lens (IOL) with diffractive asymmetrical light distribution. SETTING: Vissum-Instituto de Oftalmologico de Alicante, Alicante, Spain. METHODS: An Acri.Lisa 366D IOL was implanted without CTR implantation in 54 eyes (Group 1) or with Acri.Ring BR 11 CTR implantation in 40 eyes (Group 2). Intraocular optical quality in vivo was characterized by the difference between the postoperative total and corneal optical aberrations. Visual, refractive, and intraocular optical outcomes were evaluated 3 months postoperatively. Main outcome measures included postoperative residual refraction, uncorrected and corrected far and near visual acuities, intraocular aberrations, the Strehl ratio, and the modulation transfer function (MTF). RESULTS: The postoperative means in Group 1 were spherical equivalent, 0.31 +/- 0.45 diopters (D); uncorrected distance acuity, 0.79 +/- 0.19; best corrected distance acuity, 0.95 +/- 0.11; uncorrected near acuity, 0.77 +/- 0.21; best corrected near acuity, 0.89 +/- 0.14; best distance-corrected acuity, 0.90 +/- 0.12. The Group 2 means were -0.18 +/- 0.60 D, 0.74 +/- 0.23, 0.98 +/- 0.07, 0.72 +/- 0.22, 0.86 +/- 0.14, and 0.86 +/- 0.14, respectively. Group 2 had a statistically significant reduction in intraocular aberrations and a significant increase in MTF values and Strehl ratios compared with Group 1. CONCLUSION: Combined use of the CTR and Acri.Lisa 366D IOL provided good efficacy, predictability, and safety and increased the intraocular optical performance, suggesting better IOL stability.
引用
收藏
页码:1468 / 1475
页数:8
相关论文
共 31 条
[1]   Prospective study of the Acri.LISA bifocal intraocular lens [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Senaris, Ana ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11) :1930-1935
[2]   Outcomes of microincision cataract surgery versus coaxial phacoemulsification [J].
Alió, J ;
Rodríguez-Prats, JL ;
Galal, A ;
Ramzy, M .
OPHTHALMOLOGY, 2005, 112 (11) :1997-2003
[3]  
Alio J. L., 2004, MICS MICROINCISION C, P1
[4]   Retinal image quality after microincision intraocular lens implantation [J].
Alió, JL ;
Schimchak, P ;
Montés-Micó, R ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (08) :1557-1560
[5]   Near vision restoration with refractive lens exchange and pseudoaccommodating and multifocal refractive and diffractive intraocular lenses -: Comparative clinical study [J].
Alió, JL ;
Tavolato, M ;
De la Hoz, F ;
Claramonte, P ;
Rodríguez-Prats, JL ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (12) :2494-2503
[6]   Clinical outcomes and intraocular optical quality of a diffractive multifocal intraocular lens with asymmetrical light distribution [J].
Alio, Jorge L. ;
Elkady, Bassarn ;
Ortiz, Dolores ;
Bernabeu, Gonzalo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06) :942-948
[7]   Tilt and decentration of three-piece foldable high-refractive silicone and hydrophobic acrylic Intraocular lenses with 6-mm optics in an intraindividual comparison [J].
Baumeister, M ;
Neidhardt, B ;
Strobel, J ;
Kohnen, T .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (06) :1051-1058
[8]  
Bellucci Roberto, 2005, Curr Opin Ophthalmol, V16, P33, DOI 10.1097/00055735-200502000-00006
[9]   MONOCULAR VERSUS BINOCULAR VISUAL ACUITY [J].
CAMPBELL, FW ;
GREEN, DG .
NATURE, 1965, 208 (5006) :191-&
[10]   Can we measure wave aberration in patients with diffractive 10Ls? [J].
Charman, W. Neil ;
Montes-Mico, Robert ;
Radhakrishnan, Hema .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11) :1997-1997