Dose distribution calculation for in-vivo X-ray fluorescence scanning

被引:0
作者
Figueroa, R. G. [1 ]
Lozano, E. [2 ]
Valente, M. [3 ]
机构
[1] Univ La Frontera, Dept Ciencias Fis, Temuco 4811230, Chile
[2] Inst Nacl Canc, Unidad Fis Med, Santiago, Chile
[3] Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina
关键词
Dosimetry; in-vivo X-ray fluorescence; scanning image XRF and Monte Carlo simulation; OPTIMIZATION;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In-vivo X-ray fluorescence constitutes a useful and accurate technique, worldwide established for constituent elementary distribution assessment. Actually, concentration distributions of arbitrary user-selected elements can be achieved along sample surface with the aim of identifying and simultaneously quantifying every constituent element. The method is based on the use of a collimated X-ray beam reaching the sample. However, one common drawback for considering the application of this technique for routine clinical examinations was the lack of information about associated dose delivery. This work presents a complete study of the dose distribution resulting from an in-vivo X-ray fluorescence scanning for quantifying biohazard materials on human hands. Absorbed dose has been estimated by means of dosimetric models specifically developed to this aim. In addition, complete dose distributions have been obtained by means of full radiation transport calculations in based on stochastic Monte Carlo techniques. A dedicated subroutine has been developed using the PENELOPE 2008 main code also integrated with dedicated programs -MatLab supported- for 3D dose distribution visualization. The obtained results show very good agreement between approximate analytical models and full descriptions by means of Monte Carlo simulations.
引用
收藏
页码:339 / 342
页数:4
相关论文
共 17 条
[1]  
Botta F, 2009, J NUCL MED, V50
[2]   An optimized Monte Carlo (PENELOPE) code for the characterization of gel-layer detectors in radiotherapy [J].
Castellano, G. ;
Brusa, D. ;
Carrara, M. ;
Gambarini, G. ;
Valente, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) :502-505
[3]   Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method [J].
Dilmanian, FA ;
Zhong, Z ;
Ren, B ;
Wu, XY ;
Chapman, LD ;
Orion, I ;
Thomlinson, WC .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) :933-946
[4]   PHOTON-BEAM ENERGY DEPOSITION KERNELS FOR INVERSE RADIOTHERAPY PLANNING [J].
EKLOF, A ;
AHNESJO, A ;
BRAHME, A .
ACTA ONCOLOGICA, 1990, 29 (04) :447-454
[5]  
El-Amri F., 1997, RADIOANAL NUCL CHEM, V217, P205
[6]   The localisation and micro-mapping of copper and other trace elements in breast tumours using a synchrotron micro-XRF system [J].
Farquharson, M. J. ;
Geraki, K. ;
Falkenberg, G. ;
Leek, R. ;
Harris, A. .
APPLIED RADIATION AND ISOTOPES, 2007, 65 (02) :183-188
[7]  
Gambarini G., 2006, J PHYS C SERIES, V4, P466
[8]   A GENERALIZED PENCIL BEAM ALGORITHM FOR OPTIMIZATION OF RADIATION-THERAPY [J].
GUSTAFSSON, A ;
LIND, BK ;
BRAHME, A .
MEDICAL PHYSICS, 1994, 21 (03) :343-357
[9]  
Jianjun N., 2010, ATMOS ENVIRON, V44, P235
[10]   Application of X-ray fluorescence spectrometry to determination and quantitation of metals in vegetal material [J].
Margui, E. ;
Queralt, I. ;
Hidalgo, M. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2009, 28 (03) :362-372