Sample enrichment by using monolithic precolumns in microcolumn liquid chromatography

被引:34
作者
Lim, LW [1 ]
Hirose, K [1 ]
Tatsumi, S [1 ]
Uzu, H [1 ]
Mizukami, M [1 ]
Takeuchi, T [1 ]
机构
[1] Gifu Univ, Fac Engn, Dept Chem, Gifu 5011193, Japan
关键词
sample enrichment; monolithic precolumns; water analysis; phthalates;
D O I
10.1016/j.chroma.2004.01.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An on-line sample enrichment system was designed using monolithic precolumns in microcolumn LC. The monolithic ODS capillary columns were prepared via in situ sol-gel processes. The enrichment efficiency of the monolithic columns was tested by using phthalates as the analytes. The relative standard deviations (n = 6) for the retention time, peak area and peak height were between 0.4 and 1.2%, 0.9 and 5.5% and 0.4 and 3.9%,, respectively. The system was linear (R-2 > 0.99) within the working sample concentration and sample volume ranges. Comparing to 0.2 mul injection with a typical sample injector, the theoretical plate number of a same separation column was increased by 3-6-fold when the precolumn unit was used for sample injection. The recoveries of the analytes were between 88 and 120%, and the sample volume that could be injected into the system was increased up to 5000-fold. The limits of detection were improved by more than 2000-fold and were between 0.21 and 0.87 ng ml(-1) even with a UV absorbance detector. This system was applied to the determination of phthalates contained in laboratory distilled water and tap water samples. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 18 条
[1]   Trace determination of priority pesticides in water by means of high-speed on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry using turbulent-flow chromatography columns for enrichment and a short monolithic column for fast liquid chromatographic separation [J].
Asperger, A ;
Efer, J ;
Koal, T ;
Engewald, W .
JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) :109-119
[2]   Comparative study on the column performance of microparticulate 5-μm C18-bonded and monolithic C18-bonded reversed-phase columns in high-performance liquid chromatography [J].
Bidlingmaier, B ;
Unger, KK ;
von Doehren, N .
JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) :11-16
[3]  
BRINKMAN UAT, 1994, SAMPLE PREPARATION B, P1
[4]   On-line preconcentration, ion chromatographic separation and spectrophotometric determination of palladium at trace level [J].
Bruzzoniti, MC ;
Mucchino, C ;
Tarasco, E ;
Sarzanini, C .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1007 (1-2) :93-100
[5]   SilicaROD™ -: A new challenge in fast high-performance liquid chromatography separations [J].
Cabrera, K ;
Wieland, G ;
Lubda, D ;
Nakanishi, K ;
Soga, N ;
Minakuchi, H ;
Unger, KK .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (01) :50-53
[6]   Packing materials and separation efficiencies in capillary electrochromatography [J].
Fujimoto, C .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (04) :291-301
[7]  
Fujimoto C, 2000, HRC-J HIGH RES CHROM, V23, P89
[8]  
LIM LW, 2001, ANAL SCI S, V17, P1887
[9]   Determination of trace level bromate and perchlorate in drinking water by ion chromatography with an evaporative preconcentration technique [J].
Liu, YJ ;
Mou, S ;
Heberling, S .
JOURNAL OF CHROMATOGRAPHY A, 2002, 956 (1-2) :85-91
[10]   Automated trace enrichment and determination of metals using a combination of supported liquid membrane for sample pretreatment and graphite furnace atomic absorption spectrometry for the determination [J].
Malcus, F ;
Djane, NK ;
Mathiasson, L ;
Johansson, G .
ANALYTICA CHIMICA ACTA, 1996, 327 (03) :295-300