Imaging properties in two-photon excitation microscopy and effects of refractive-index mismatch in thick specimens

被引:53
|
作者
de Grauw, GJ
Vroom, JM
van der Voort, HTM
Gerritsen, HC
机构
[1] Univ Utrecht, NL-3508 TA Utrecht, Netherlands
[2] Sci Volume Imaging BV, NL-1213 XS Hilversum, Netherlands
关键词
D O I
10.1364/AO.38.005995
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The detrimental effects of a refractive-index mismatch on the image formation in a two-photon microscope were investigated. Point-spread functions (PSF's) were recorded with an oil-immersion objective numerical aperture (NA) of 1.3 and a water-immersion objective NA of 1.2 in an aqueous sample at different depths. For the oil-immersion objective the enlargement of the PSF volume with increasing depth yields an axial and a lateral loss in resolution of approximately 380% and 160%, respectively, at a 90-mu m depth in the sample. For the water-immersion objective no resolution decrease was found. Measurements on a thick aqueous biofilm sample shows the importance of matching the refractive index between immersion fluid and sample. With a good match, no loss in image resolution is observed. (C) 1999 Optical Society of America.
引用
收藏
页码:5995 / 6003
页数:9
相关论文
共 50 条
  • [1] Imaging properties in two-photon excitation microscopy and effects of refractive-index mismatch in thick specimens
    De Grauw, Cees J.
    Vroom, Jurrien M.
    Van Der Voort, Hans T. M.
    Gerritsen, Hans C.
    Applied Optics, 1999, 38 (28): : 5995 - 6003
  • [2] Image distortions of two-photon laser scanning microscopy induced by refractive-index mismatch of coverslips
    Chen, Deqiang
    Zhou, Yongjun
    Huang, Wenhao
    Xia, Andong
    Guangzi Xuebao/Acta Photonica Sinica, 2001, 30 (12):
  • [3] Imaging of optically thick specimen using two-photon excitation microscopy
    Gerritsen, HC
    De Grauw, CJ
    MICROSCOPY RESEARCH AND TECHNIQUE, 1999, 47 (03) : 206 - 209
  • [4] Imaging of optically thick specimen using two-photon excitation microscopy
    Debye Institute, Utrecht University, 3508 TA Utrecht, Netherlands
    不详
    Microsc. Res. Tech., 3 (206-209):
  • [5] Light Sheet Fluorescence Microscopy (LSFM) for Two-Photon Excitation Imaging of Thick Samples
    Sancataldo, Giuseppe
    Lavagnino, Zeno
    d'Amora, Marta
    Zanacchi, Francesca Cella
    Diaspro, Alberto
    BIOPHYSICAL JOURNAL, 2015, 108 (02) : 326A - 326A
  • [6] Effects of refractive-index mismatch on three-dimensional optical data-storage density in a two-photon bleaching polymer
    Day, Daniel
    Gu, Min
    Applied Optics, 1998, 37 (26): : 6299 - 6304
  • [7] Effects of refractive-index mismatch on three-dimensional optical data-storage density in a two-photon bleaching polymer
    Day, D
    Gu, M
    APPLIED OPTICS, 1998, 37 (26): : 6299 - 6304
  • [8] Quantitative imaging of metabolism by two-photon excitation microscopy
    Piston, DW
    Knobel, SM
    CONFOCAL MICROSCOPY, 1999, 307 : 351 - 368
  • [9] Refractive-index-mismatch induced aberrations in single-photon and two-photon microscopy and the use of aberration correction
    Booth, MJ
    Wilson, T
    JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (03) : 266 - 272
  • [10] Two-photon excitation microscopy
    Diaspro, A
    Chirico, G
    ADVANCES IN IMAGING AND ELECTRON PHYSICS, VOL 126, 2003, 126 : 195 - 286