Imaging properties in two-photon excitation microscopy and effects of refractive-index mismatch in thick specimens

被引:54
作者
de Grauw, GJ
Vroom, JM
van der Voort, HTM
Gerritsen, HC
机构
[1] Univ Utrecht, NL-3508 TA Utrecht, Netherlands
[2] Sci Volume Imaging BV, NL-1213 XS Hilversum, Netherlands
关键词
D O I
10.1364/AO.38.005995
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The detrimental effects of a refractive-index mismatch on the image formation in a two-photon microscope were investigated. Point-spread functions (PSF's) were recorded with an oil-immersion objective numerical aperture (NA) of 1.3 and a water-immersion objective NA of 1.2 in an aqueous sample at different depths. For the oil-immersion objective the enlargement of the PSF volume with increasing depth yields an axial and a lateral loss in resolution of approximately 380% and 160%, respectively, at a 90-mu m depth in the sample. For the water-immersion objective no resolution decrease was found. Measurements on a thick aqueous biofilm sample shows the importance of matching the refractive index between immersion fluid and sample. With a good match, no loss in image resolution is observed. (C) 1999 Optical Society of America.
引用
收藏
页码:5995 / 6003
页数:9
相关论文
共 18 条
[1]   A modified chemostat system to study the ecology of oral biofilms [J].
Bradshaw, DJ ;
Marsh, PD ;
Schilling, KM ;
Cummins, D .
JOURNAL OF APPLIED BACTERIOLOGY, 1996, 80 (02) :124-130
[2]   THE INFLUENCE OF SPECIMEN REFRACTIVE-INDEX, DETECTOR SIGNAL INTEGRATION, AND NONUNIFORM SCAN SPEED ON THE IMAGING PROPERTIES IN CONFOCAL MICROSCOPY [J].
CARLSSON, K .
JOURNAL OF MICROSCOPY-OXFORD, 1991, 163 :167-178
[3]   Multiphoton excitation provides optical sections from deeper within scattering specimens than confocal imaging [J].
Centonze, VE ;
White, JG .
BIOPHYSICAL JOURNAL, 1998, 75 (04) :2015-2024
[4]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[5]   THE EFFECTS OF TOTAL INTERNAL-REFLECTION ON THE SPREAD FUNCTION ALONG THE AXIS IN CONFOCAL MICROSCOPY [J].
ENTWISTLE, A .
JOURNAL OF MICROSCOPY-OXFORD, 1995, 180 (02) :148-157
[6]   ABERRATIONS IN CONFOCAL FLUORESCENCE MICROSCOPY INDUCED BY MISMATCHES IN REFRACTIVE-INDEX [J].
HELL, S ;
REINER, G ;
CREMER, C ;
STELZER, EHK .
JOURNAL OF MICROSCOPY, 1993, 169 :391-405
[7]   REFRACTIVE-INDEX-INDUCED ABERRATIONS IN 2-PHOTON CONFOCAL FLUORESCENCE MICROSCOPY [J].
JACOBSEN, H ;
HANNINEN, P ;
SOINI, E ;
HELL, SW .
JOURNAL OF MICROSCOPY-OXFORD, 1994, 176 :226-230
[8]  
Jacobsen H., 1995, Bioimaging, V3, P39, DOI 10.1002/1361-6374(199503)3:1<39::AID-BIO5>3.3.CO
[9]  
2-Z
[10]  
Kano H., 1996, Bioimaging, V4, P187, DOI 10.1002/1361-6374(199609)4:3<187::AID-BIO9>3.3.CO