Characterization of nonvolatile polar compounds from Brazilian oils by electrospray ionization with FT-ICR MS and Orbitrap-MS

被引:51
作者
Vanini, Gabriela [1 ]
Barra, Thamara A. [1 ]
Souza, Lindamara M. [2 ]
Madeira, Nata C. L. [2 ]
Gomes, Alexandre O. [3 ]
Romao, Wanderson [2 ,4 ]
Azevedo, Debora A. [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Chem, BR-21941598 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Espirito Santo, Dept Chem, Petroleorn & Forens Chem Lab, BR-29075910 Vitoria, ES, Brazil
[3] Cenpes, Petrobras, BR-21941915 Rio De Janeiro, RJ, Brazil
[4] Fed Inst Educ Sci & Technol Espirito Santo, BR-29106010 Vila Velha, ES, Brazil
关键词
Petroleomics; Crude oil; Mass spectrometry; FT-ICR MS; Orbitrap-MS; RESOLUTION MASS-SPECTROMETRY; CRUDE-OIL; ULTRAHIGH-RESOLUTION; RESOLVING POWER; ASPHALTENES; PETROLEOMICS; ACCURACY; ACIDS;
D O I
10.1016/j.fuel.2020.118790
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Among the different types of available high-resolution mass spectrometers, Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) and Orbitrap-MS are important tools for the study of nonvolatile crude oil fraction composition. No in deep comparison between each analyzer was still performed, mostly with a wide broad of real crude oil samples. Therefore, in this study a representative set of 30 Brazilian crude oils with a wide range of American Petroleum Institute (API) gravity (13.1-53.7) were considered. The ICR and Orbitrap analyzers allowed the elemental composition to be obtained by accurate mass measurements, and the most abundant species were mainly N, N-2, O-3, O-1, O-2, NO2, NS, NOS, and OS classes. In general, FT-ICR MS favored the detection of higher molecular weight analyzes in relation to Orbitrap-MS. The notable distribution of the heteroatom classes showed that crude oils with intermediate API gravity presented a higher relative abundance of nitrogenous compounds (N-x), while lighter oils presented a higher abundance of oxygenated compounds (O-1). The heavier ones had a higher abundance of O-2 class, which was not verified by Orbitrap-MS, where a prevalence of O-2 class was detected in major crude oils. An increase in average molar weight values was observed when we changed technique (Orbitrap-MS -> FT-ICR MS) and ionization mode (negative -> positive), since FT-ICR MS detected substances with higher m/z. In this way, this work examines the application of two different high-resolution mass analyzers, and shows the versatility and analytical response of each one within petroleomics.
引用
收藏
页数:13
相关论文
共 45 条
  • [1] Comprehensive Two-Dimensional Gas Chromatography Advances in Technology and Applications: Biennial Update
    Amaral, Michelle S. S.
    Nolvachai, Yada
    Marriott, Philip J.
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (01) : 85 - 104
  • [2] ASTM, 2018, D66418E ASTM INT
  • [3] ASTM, 2017, D462917 ASTM INT
  • [4] Comprehensive Chemical Composition of Gas Oil Cuts Using Two-Dimensional Gas Chromatography with Time-of-Flight Mass Spectrometry and Electrospray Ionization Coupled to Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    Avila, Barbara M. F.
    Vaz, Boniek G.
    Pereira, Ricardo
    Gomes, Alexandre O.
    Pereira, Rosana C. L.
    Corilo, Yuri E.
    Simas, Rosineide C.
    Lopes Nascimento, Heliara D.
    Eberlin, Marcos N.
    Azevedo, Debora A.
    [J]. ENERGY & FUELS, 2012, 26 (08) : 5069 - 5079
  • [5] Characterization of polar compounds in a true boiling point distillation system using electrospray ionization FT-ICR mass spectrometry
    Dalmaschio, Guilherme P.
    Malacarne, Majorie M.
    de Almeida, Vinicius M. D. L.
    Pereira, Thieres M. C.
    Gomes, Alexandre O.
    de Castro, Eustaquio V. R.
    Greco, Sandro J.
    Vaz, Boniek G.
    Romao, Wanderson
    [J]. FUEL, 2014, 115 : 190 - 202
  • [6] Evidencing the crude oil corrosion by Raman spectroscopy, atomic force microscopy and electrospray ionization FT-ICR mass spectrometry
    Dias, Heloisa P.
    Dixini, Pedro V.
    Almeida, Luiz C. P.
    Vanini, Gabriela
    Castro, Eustaquio V. R.
    Aquije, Gloria M. F. V.
    Gomes, Alexandre O.
    Moura, Robson R.
    Lacerda, Valdemar, Jr.
    Vaz, Boniek G.
    Romao, Wanderson
    [J]. FUEL, 2015, 139 : 328 - 336
  • [7] Complementarity of Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and high temperature comprehensive two-dimensional gas chromatography for the characterization of resin fractions from vacuum gas oils
    Dutriez, Thomas
    Courtiade, Marion
    Ponthus, Jeremie
    Thiebaut, Didier
    Dulot, Hugues
    Hennion, Marie-Claire
    [J]. FUEL, 2012, 96 (01) : 108 - 119
  • [8] An alternative for value aggregation to the sugarcane chain: Biohydrogen and volatile fatty acids production from sugarcane molasses in mesophilic expanded granular sludge bed reactors
    Ferreira Freitas, Isabele Baima
    de Menezes, Camila Aparecida
    Silva, Edson Luiz
    [J]. FUEL, 2020, 260
  • [9] Hydrodenitrogenation of petroleum
    Furimsky, E
    [J]. CATALYSIS REVIEWS-SCIENCE AND ENGINEERING, 2005, 47 (03): : 297 - 489
  • [10] Hybrid mass spectrometers for tandem mass Spectrometry
    Glish, Gary L.
    Burinsky, David J.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (02) : 161 - 172