Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group

被引:613
作者
Frerichs, Inez [1 ]
Amato, Marcelo B. P. [2 ]
van Kaam, Anton H. [3 ]
Tingay, David G. [4 ]
Zhao, Zhanqi [5 ]
Grychtol, Bartlomiej [6 ]
Bodenstein, Marc [7 ]
Gagnon, Herve [8 ]
Bohm, Stephan H. [9 ]
Teschner, Eckhard [10 ]
Stenqvist, Ola [11 ]
Mauri, Tommaso [12 ]
Torsani, Vinicius [2 ]
Camporota, Luigi [13 ]
Schibler, Andreas [14 ]
Wolf, Gerhard K. [15 ]
Gommers, Diederik [16 ]
Leonhardt, Steffen [17 ]
Adler, Andy [8 ]
机构
[1] Univ Med Ctr Schleswig Holstein, Dept Anesthesiol & Intens Care Med, Campus Kiel,Arnold Heller Str 3, D-24105 Kiel, Germany
[2] Univ Sao Paulo, Fac Med, Hosp Clin, Pulm Div,Heart Inst InCor, Sao Paulo, Brazil
[3] Emma Childrens Hosp, Acad Med Ctr, Dept Neonatol, Amsterdam, Netherlands
[4] Murdoch Childrens Res Inst, Neonatal Res, Parkville, Vic, Australia
[5] Furtwangen Univ, Inst Tech Med, Villingen Schwenningen, Germany
[6] Fraunhofer Project Grp Automat Med & Biotechnol P, Mannheim, Germany
[7] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Anesthesiol, Mainz, Germany
[8] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON, Canada
[9] Swisstom AG, Landquart, Switzerland
[10] Drager Med GmbH, Lubeck, Germany
[11] Sahlgrens Univ Hosp, Dept Anesthesiol & Intens Care Med, Gothenburg, Sweden
[12] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Dept Anesthesia Crit Care & Emergency, Milan, Italy
[13] Guys & St Thomas NHS Fdn Trust, Dept Adult Crit Care, London, England
[14] Mater Res Univ Queensland, Paediat Crit Care Res Grp, South Brisbane, Qld, Australia
[15] Ludwig Maximilians Univ Munchen, Childrens Hosp Traunstein, Munich, Germany
[16] Erasmus MC, Dept Adult Intens Care, Rotterdam, Netherlands
[17] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Philips Chair Med Informat Technol, Aachen, Germany
基金
英国工程与自然科学研究理事会;
关键词
REGIONAL LUNG VENTILATION; END-EXPIRATORY-PRESSURE; RESPIRATORY-DISTRESS-SYNDROME; TIDAL VENTILATION; ENDOTRACHEAL SUCTION; SPATIAL-DISTRIBUTION; VOLUME; PRETERM; RECRUITMENT; PERFUSION;
D O I
10.1136/thoraxjnl-2016-208357
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Electrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function testing in patients with chronic lung diseases. As EIT becomes an established medical technology, it requires consensus examination, nomenclature, data analysis and interpretation schemes. Such consensus is needed to compare, understand and reproduce study findings from and among different research groups, to enable large clinical trials and, ultimately, routine clinical use. Recommendations of how EIT findings can be applied to generate diagnoses and impact clinical decision-making and therapy planning are required. This consensus paper was prepared by an international working group, collaborating on the clinical promotion of EIT called TRanslational EIT developmeNt stuDy group. It addresses the stated needs by providing (1) a new classification of core processes involved in chest EIT examinations and data analysis, (2) focus on clinical applications with structured reviews and outlooks (separately for adult and neonatal/paediatric patients), (3) a structured framework to categorise and understand the relationships among analysis approaches and their clinical roles, (4) consensus, unified terminology with clinical user-friendly definitions and explanations, (5) a review of all major work in thoracic EIT and (6) recommendations for future development (193 pages of online supplements systematically linked with the chief sections of the main document). We expect this information to be useful for clinicians and researchers working with EIT, as well as for industry producers of this technology.
引用
收藏
页码:83 / 93
页数:11
相关论文
共 100 条
  • [1] Whither lung EIT: Where are we, where do we want to go and what do we need to get there?
    Adler, Andy
    Amato, Marcelo B.
    Arnold, John H.
    Bayford, Richard
    Bodenstein, Marc
    Boehm, Stephan H.
    Brown, Brian H.
    Frerichs, Inez
    Stenqvist, Ola
    Weiler, Norbert
    Wolf, Gerhard K.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2012, 33 (05) : 679 - 694
  • [2] Alves Sergio H S, 2014, Ann Am Thorac Soc, V11, P186, DOI 10.1513/AnnalsATS.201306-142OC
  • [3] Distribution of tidal ventilation during volume-targeted ventilation is variable and influenced by age in the preterm lung
    Armstrong, Ruth K.
    Carlisle, Hazel R.
    Davis, Peter G.
    Schibler, Andreas
    Tingay, David G.
    [J]. INTENSIVE CARE MEDICINE, 2011, 37 (05) : 839 - 846
  • [4] APPLIED POTENTIAL TOMOGRAPHY
    BARBER, DC
    BROWN, BH
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09): : 723 - 733
  • [5] Influence of tidal volume on ventilation inhomogeneity assessed by electrical impedance tomography during controlled mechanical ventilation
    Becher, T.
    Kott, M.
    Schaedler, D.
    Vogt, B.
    Meinel, T.
    Weiler, N.
    Frerichs, I.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (06) : 1137 - 1146
  • [6] Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies
    Becher, Tobias
    Vogt, Barbara
    Kott, Matthias
    Schaedler, Dirk
    Weiler, Norbert
    Frerichs, Inez
    [J]. PLOS ONE, 2016, 11 (03):
  • [7] Assessment of respiratory system compliance with electrical impedance tomography using a positive end-expiratory pressure wave maneuver during pressure support ventilation: a pilot clinical study
    Becher, Tobias H.
    Bui, Simon
    Zick, Guenther
    Blaeser, Daniel
    Schaedler, Dirk
    Weiler, Norbert
    Frerichs, Inez
    [J]. CRITICAL CARE, 2014, 18 (06):
  • [8] Electrical impedance tomography can rapidly detect small pneumothoraces in surfactant-depleted piglets
    Bhatia, Risha
    Schmoelzer, Georg M.
    Davis, Peter G.
    Tingay, David G.
    [J]. INTENSIVE CARE MEDICINE, 2012, 38 (02) : 308 - 315
  • [9] Detection of 'best' positive end-expiratory pressure derived from electrical impedance tomography parameters during a decremental positive end-expiratory pressure trial
    Blankman, Paul
    Hasan, Djo
    Erik, Groot Jebbink
    Gommers, Diederik
    [J]. CRITICAL CARE, 2014, 18 (03):
  • [10] Ventilation distribution measured with EIT at varying levels of pressure support and Neurally Adjusted Ventilatory Assist in patients with ALI
    Blankman, Paul
    Hasan, Djo
    van Mourik, Martijn S.
    Gommers, Diederik
    [J]. INTENSIVE CARE MEDICINE, 2013, 39 (06) : 1057 - 1062