Stented segment length as an independent predictor of restenosis

被引:234
作者
Kobayashi, Y [1 ]
De Gregorio, J [1 ]
Kobayashi, N [1 ]
Akiyama, T [1 ]
Reimers, B [1 ]
Finci, L [1 ]
Di Mario, C [1 ]
Colombo, A [1 ]
机构
[1] Ctr Cuore Columbus, I-20145 Milan, Italy
关键词
D O I
10.1016/S0735-1097(99)00303-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to evaluate the relation between stented segment length and restenosis. BACKGROUND Multiple or long coronary stents are now being implanted in long lesions or in tandem lesions. A longer stented segment might result in a higher probability of restenosis. However, there is little information available on the relation between stented segment length and restenosis. METHODS Between April 1995 and December 1996, 725 patients with 1,090 lesions underwent stenting. Lesions were divided into three groups according to the length of the stented segment: 1) group I (n = 565): stented segment length less than or equal to 20 mm; 2) group II (n = 278): stented segment length >20 but less than or equal to 35 mm; and 3) group III (n = 247): stented segment length >35 mm. RESULTS There was no significant difference in the incidence of subacute stent thrombosis among the three groups (0.4% in group I, 0.4% in group II, 1.2% in group III; p = NS). The minimal lumen diameter (MLD) after stenting was greater in group I than in group III (3.04 +/- 0.60 mm in group I, 3.01 +/- 0.54 mm in group II, 2.91 +/- 0.58 mm in group III; p < 0.05). At follow up, a smaller MLD was observed in group III as compared with group I and group II (2.04 +/- 0.93 mm in group I, 1.92 +/- 1.00 mm in group II, 1.47 +/- 0.97 mm in group III; p < 0.01). The restenosis rates were 23.9% in group I, 34.6% in group II and 47.2% in group III (p < 0.01). Using multivariate analysis, the longer stented segment, the angiographic reference vessel diameter and the percent diameter stenosis after stenting were independent predictors of restenosis. CONCLUSIONS The present study shows that a longer stented segment is an independent predictor of restenosis without an influence on the risk of subacute thrombosis. (J Am Coll Cardiol 1999; 34:651-9) (C) 1999 by the American College of Cardiology.
引用
收藏
页码:651 / 659
页数:9
相关论文
共 25 条
  • [1] PREDICTORS OF THROMBOTIC COMPLICATIONS AFTER PLACEMENT OF THE FLEXIBLE COIL STENT
    AGRAWAL, SK
    HO, DSW
    LIU, MW
    IYER, S
    HEARN, JA
    CANNON, AD
    MACANDER, PJ
    DEAN, LS
    BAXLEY, WA
    ROUBIN, GS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (16) : 1216 - 1219
  • [2] First International New Intravascular Rigid-Flex Endovascular Stent Study (FINESS): Clinical and angiographic results after elective and urgent stent implantation
    Almagor, Y
    Feld, S
    Kiemeneij, F
    Serruys, PW
    Morice, MC
    Colombo, A
    Macaya, C
    Guermonprez, JL
    Marco, J
    Erbel, R
    Penn, IM
    Bonan, R
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (04) : 847 - 854
  • [3] A NOVEL STRATEGY FOR STENT DEPLOYMENT IN THE TREATMENT OF ACUTE OR THREATENED CLOSURE COMPLICATING BALLOON CORONARY ANGIOPLASTY - USE OF SHORT OR STANDARD (OR BOTH) SINGLE OR MULTIPLE PALMAZ-SCHATZ STENTS
    COLOMBO, A
    GOLDBERG, SL
    ALMAGOR, Y
    MAIELLO, L
    FINCI, L
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) : 1887 - 1891
  • [4] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [5] Eeckhout E, 1996, CATHETER CARDIO DIAG, V39, P302
  • [6] RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE
    ELLIS, SG
    SAVAGE, M
    FISCHMAN, D
    BAIM, DS
    LEON, M
    GOLDBERG, S
    HIRSHFELD, JW
    CLEMAN, MW
    TEIRSTEIN, PS
    WALKER, C
    BAILEY, S
    BUCHBINDER, M
    TOPOL, EJ
    SCHATZ, RA
    [J]. CIRCULATION, 1992, 86 (06) : 1836 - 1844
  • [7] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [8] BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS
    GOLDBERG, SL
    COLOMBO, A
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    TOBIS, JM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) : 996 - 1003
  • [9] Intracoronary stent implantation without ultrasound guidance and with replacement of conventional anticoagulation by antiplatelet therapy - 30-day clinical outcome of the French Multicenter Registry
    Karrillon, GJ
    Morice, MC
    Benveniste, E
    Bunouf, P
    Aubry, P
    Cattan, S
    Chevalier, B
    Commeau, P
    Cribier, A
    Eiferman, C
    Grollier, G
    Guerin, Y
    Henry, M
    Lefevre, T
    Livarek, B
    Louvard, Y
    Marco, J
    Makowski, S
    Monassier, JP
    Pernes, JM
    Rioux, P
    Spaulding, C
    Zemour, G
    [J]. CIRCULATION, 1996, 94 (07) : 1519 - 1527
  • [10] THE IMPORTANCE OF ACUTE LUMINAL DIAMETER IN DETERMINING RESTENOSIS AFTER CORONARY ATHERECTOMY OR STENTING
    KUNTZ, RE
    SAFIAN, RD
    CARROZZA, JP
    FISHMAN, RF
    MANSOUR, M
    BAIM, DS
    [J]. CIRCULATION, 1992, 86 (06) : 1827 - 1835