Ultra-low flow nanospray for the normalization of conventional liquid chromatography/mass spectrometry through equimolar response: standard-free quantitative estimation of metabolite levels in drug discovery

被引:63
作者
Valaskovic, GA
Utley, L
Lee, MS
Wu, JT [1 ]
机构
[1] New Object Inc, Woburn, MA 01801 USA
[2] Millennium Pharmaceut Inc, Cambridge, MA 02139 USA
[3] Milestone Dev Serv, Newtown, PA 18940 USA
关键词
D O I
10.1002/rcm.2414
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nanospray experiments were performed on an ensemble of drug molecules and their commonly known metabolites to compare performance with conventional electrospray ionization (ESI) and to evaluate equimolar response capabilities. Codeine, dextromethorphan, tolbutamide, phenobarbital, cocaine, and morphine were analyzed along with their well-known metabolites that were formed via hydroxylation, dealkylation, hydrolysis, and glucuronidation. Nanospray exhibited a distinct trend toward equimolar response when flow rate was reduced from 25 nL/min to less than 10 nL/min. A more uniform response between the parent drug and the corresponding metabolites was obtained at flow rates of 10 nL/min or lower. The largest discrepancy was within +/- 50% for plasma samples. Nanospray was used as a calibrator for conventional ESI liquid chromatography/tandem mass spectrometry (LC/MS/MS) and normalization factors were applied to the quantitation of an acylglucuronide metabolite of a proprietary compound in rat plasma. A nanospray calibration method was developed with the standard curve of the parent drug to generate quantitative results for drug metabolites within +/- 20% of that obtained with reference standards and conventional ESI. The nanospray method provides a practical solution for the quantitative estimation of drug metabolites in drug discovery when reference standards are not available. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1087 / 1096
页数:10
相关论文
共 40 条
[1]  
ACKERMANN BL, 2002, CURR TOP MED CHEM, V2, P56
[2]   Atmospheric pressure ionization LC/MS/MS techniques for drug disposition studies [J].
Brewer, E ;
Henion, J .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (04) :395-402
[3]   Mechanistic aspects of electrospray ionization [J].
Bruins, AP .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :345-357
[4]   Effect of affinity for droplet surfaces on the fraction of analyte molecules charged during electrospray droplet fission [J].
Cech, NB ;
Enke, CG .
ANALYTICAL CHEMISTRY, 2001, 73 (19) :4632-4639
[5]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[6]   A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes [J].
Enke, CG .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4885-4893
[7]   QUANTITATIVE-ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY - THE DETERMINATION OF THE RENIN INHIBITOR CP-80,794 IN HUMAN SERUM [J].
FOUDA, H ;
NOCERINI, M ;
SCHNEIDER, R ;
GEDUTIS, C .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (02) :164-167
[8]   Reduction of signal suppression effects in ESI-MS using a nanosplitting device [J].
Gangl, ET ;
Annan, M ;
Spooner, N ;
Vouros, P .
ANALYTICAL CHEMISTRY, 2001, 73 (23) :5635-5644
[9]   Tuning of an electrospray ionization source for maximum peptide-ion transmission into a mass spectrometer [J].
Geromanos, S ;
Freckleton, G ;
Tempst, P .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :777-790
[10]   DETERMINATION OF L-365,260, A NEW CHOLECYSTOKININ RECEPTOR (CCK-B) ANTAGONIST, IN PLASMA BY LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
GILBERT, JD ;
HAND, EL ;
YUAN, AS ;
OLAH, TV ;
COVEY, TR .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (02) :63-68