A Fluoroscopic Grid in Supine Total Hip Arthroplasty Improving Cup Position, Limb Length, and Hip Offset

被引:28
作者
Gililland, Jeremy M. [1 ]
Anderson, Lucas A. [1 ]
Boffeli, Shannon L. [1 ]
Pelt, Christopher E. [1 ]
Peters, Christopher L. [1 ]
Kubiak, Erik N. [1 ]
机构
[1] Univ Utah, Sch Med, Dept Orthopaed Surg, Salt Lake City, UT 84108 USA
关键词
total hip arthroplasty; fluoroscopic grid; limb length; ACETABULAR COMPONENT; POLYETHYLENE WEAR; DISCREPANCY; REPLACEMENT; ORIENTATION;
D O I
10.1016/j.arth.2012.03.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We hypothesized that use of a novel fluoroscopic grid would decrease operative time: and component positioning variability during anterior supine total hip arthroplasty (THA). We reviewed 99 anterior supine THAs: 39 using a fluoroscopic grid, and 60 using fluoroscopy alone.: Goals were cup abduction of 40 degrees +/- 10 degrees and limb length and hip offset within 10 mm of the contralateral side. Surgical time was decreased in the study group (79 vs 94 minutes, P = .002). In the study group, more components met the goal for cup abduction (97% vs 83%, P = .046), limb length (100% vs 88%, P = .04), hip offset (85% vs 67%, P = .047), and all 3 combined (82% vs 52%, P = .002). We demonstrated decreased component positioning variability during anterior supine THA with assistance of a fluoroscopic grid.
引用
收藏
页码:111 / 116
页数:6
相关论文
共 18 条
[1]   The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement - A preliminary study of 1000 cases investigating postoperative stability [J].
Archbold, H. A. P. ;
Mockford, B. ;
Molloy, D. ;
McConway, J. ;
Ogonda, L. ;
Beverland, D. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07) :883-886
[2]  
Berend KR, 2010, J BONE JOINT SURG AM, V92A, P2737
[3]   Minimally invasive total hip arthroplasty - Development, early results, and a critical analysis [J].
Berry, DJ ;
Berger, RA ;
Callaghan, JJ ;
Dorr, LD ;
Duwelius, PJ ;
Hartzband, MA ;
Lieberman, JR ;
Mears, DC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2235-2236
[4]   The John Charnley Award Risk Factors for Cup Malpositioning Quality Improvement Through a Joint Registry at a Tertiary Hospital [J].
Callanan, Mark C. ;
Jarrett, Bryan ;
Bragdon, Charles R. ;
Zurakowski, David ;
Rubash, Harry E. ;
Freiberg, Andrew A. ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :319-329
[5]   Soft-tissue balancing of the hip - The role of femoral offset restoration [J].
Charles, MN ;
Bourne, RB ;
Davey, JR ;
Greenwald, AS ;
Morrey, BF ;
Rorabeck, CH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05) :1078-1088
[6]   Leg-length discrepancy after total hip arthroplasty [J].
Clark, CR ;
Huddleston, HD ;
Schoch, EP ;
Thomas, BJ .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2006, 14 (01) :38-45
[7]  
Devane PA, 1999, CLIN ORTHOP RELAT R, P59
[8]   Effects of limb-length discrepancy on gait economy and lower-extremity muscle activity in older adults [J].
Gurney, B ;
Mermier, C ;
Robergs, R ;
Gibson, A ;
Rivero, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (06) :907-915
[9]   Imageless navigation for insertion of the acetabular component in total hip arthroplasty -: Is it as accurate as CT-based navigation? [J].
Kalteis, T ;
Handel, A ;
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :163-167
[10]   Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration [J].
Kennedy, JG ;
Rogers, WB ;
Soffe, KE ;
Sullivan, RJ ;
Griffen, DG ;
Sheehan, LJ .