Evolving bioanalytical methods for the cardiovascular drug bosentan

被引:27
作者
Dell, D [1 ]
Lausecker, B
Hopfgartner, G
van Giersbergen, PLM
Dingemanse, J
机构
[1] Actelion Pharmaceut Ltd, CH-4123 Allschwil, Switzerland
[2] F Hoffmann La Roche, Dept Non Clin Drug Safety, Basel, Switzerland
[3] Actelion Pharmaceut Ltd, Dept Clin Pharmacol, Allschwil, Switzerland
关键词
column liquid chromatography-tandem mass spectrometry; column switching; bioanalytics; bosentan;
D O I
10.1007/BF02493366
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The history of the development of analytical methods for the determination of the cardiovascular agent bosentan and its three major metabolites in biological fluids is described, Before the advent of LC-MS-MS, conventional HPLC-UV methodology was adequate for the determination of the drug alone in samples generated from toxicology studies. The progressive changes in the methods described reflect improvements in MS instrumentation and software, the need for measuring metabolites, as well as the availability of deuterated internal standards. Finally, three LC-MS-MS methods were chosen as being suitable for routine use. The most sophisticated of these (E), involving protein precipitation, liquid-liquid extraction, and on-line solid phase extraction by automated column switching, allowed the simultaneous and sensitive determination of the drug and three metabolites in a variety of biological matrices from several species to support pharmacokinetic studies. Two further, simpler, MS methods were developed (F and G) which, compared with the sophisticated method, focussed on reduced manual effort and reduced instrumental run cycle times. The limits of quantitation were between 1 and 2 ng mL(-1) for bosentan and the three metabolites.
引用
收藏
页码:S115 / S119
页数:5
相关论文
共 3 条
  • [1] DETERMINATION OF AN ENDOTHELIN RECEPTOR ANTAGONIST IN HUMAN PLASMA BY NARROW-BORE LIQUID-CHROMATOGRAPHY AND IONSPRAY TANDEM MASS-SPECTROMETRY
    LAUSECKER, B
    HOPFGARTNER, G
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) : 75 - 83
  • [2] Simultaneous determination of bosentan and its three major metabolites in various biological matrices and species using narrow bore liquid chromatography with ion spray tandem mass spectrometric detection
    Lausecker, B
    Hess, B
    Fischer, G
    Mueller, M
    Hopfgartner, G
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 749 (01): : 67 - 83
  • [3] Endothelin antagonism with bosentan: a review of potential applications
    Roux, S
    Breu, V
    Ertel, SI
    Clozel, M
    [J]. JOURNAL OF MOLECULAR MEDICINE-JMM, 1999, 77 (04): : 364 - 376