Prediction of the variance of stereological volume estimates from systematic sections using computer-intensive methods

被引:5
作者
Mattfeldt, Torsten [1 ]
机构
[1] Univ Ulm, Dept Pathol, D-89081 Ulm, Germany
来源
JOURNAL OF MICROSCOPY-OXFORD | 2006年 / 222卷
关键词
computational statistics; computer-intensive methods; covariogram; microscopy; prediction; sampling theory; simulation; stereology; systematic sampling; transitive theory; variance; volume;
D O I
10.1111/j.1365-2818.2006.01584.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
The Cavalieri method is an unbiased estimator of the total volume of a body from its transectional areas on systematic sections. The coefficient of error (CE) of the Cavalieri estimator was predicted by a computer-intensive method. The method is based on polynomial regression of area values on section number and simulation of systematic sectioning. The measurement function is modelled as a quadratic polynomial, with an error term superimposed. The relative influence of the trend and the error component is estimated by techniques of analysis of variance. This predictor was compared with two established short-cut estimators of the CE based on transitive theory. First, all predictors were applied to data sets from six deterministic models with analytically known CE. For these models, the CE was best predicted by the older short-cut estimator and by the computer-intensive approach, if the measurement function had finite jumps. The best prediction was provided by the newer short-cut estimator when the measurement function was continuous. The predictors were also applied to published empirical datasets. The first data set consisted of 10 series of areas of systematically sectioned rat hearts with 10-13 items, the second data set consisted of 13 series of systematically sampled transectional areas of various biological structures with 38-90 items. On the whole, similar mean values for the predicted CE were obtained with the older short-cut estimator and the computer-intensive method. These ranged in the same order of magnitude as resampling estimates of the CE from the empirical data sets, which were used as a cross-check. The mean values according to the newer short-cut CE estimator ranged distinctly lower than the resampling estimates. However, for individual data sets, it happened that the closest prediction as compared to the cross-check value could be provided by any of the three methods. This finding is discussed in terms of the statistical variability of the resampling estimate itself.
引用
收藏
页码:166 / 176
页数:11
相关论文
共 28 条
  • [1] Cochran, 1977, SAMPLING TECHNIQUES
  • [2] Precision of Cavalieri sections and slices with local errors
    Cruz-Orive, LM
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1999, 193 : 182 - 198
  • [3] A review of the article:: Comments on the shortcomings of predicting the precision of Cavalieri volume estimates based upon assumed measurement functions, by Edmund!Glaser
    Cruz-Orive, LM
    García-Fiñana, M
    [J]. JOURNAL OF MICROSCOPY, 2005, 218 : 6 - 8
  • [4] Estimation of particle number by stereology: An update
    Cruz-Orive, LM
    Geiser, M
    [J]. JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2004, 17 (03): : 197 - 212
  • [5] Cruz-Orive LM., 1993, B INT STAT I, V55, P451
  • [6] ON THE PRECISION OF SYSTEMATIC-SAMPLING - A REVIEW OF MATHERONS TRANSITIVE METHODS
    CRUZORIVE, LM
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1989, 153 : 315 - 333
  • [7] STEREOLOGICAL ESTIMATION OF VOLUME RATIOS BY SYSTEMATIC SECTIONS
    CRUZORIVE, LM
    MYKING, AO
    [J]. JOURNAL OF MICROSCOPY, 1981, 122 (MAY) : 143 - 157
  • [8] Stereology of single objects
    CruzOrive, LM
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1997, 186 : 93 - 107
  • [9] New approximations for the variance in Cavalieri sampling
    García-Fiñana, M
    Cruz-Orive, LM
    [J]. JOURNAL OF MICROSCOPY, 2000, 199 (03) : 224 - 238
  • [10] Improved variance prediction for systematic sampling on R
    García-Fiñana, M
    Cruz-Orive, LM
    [J]. STATISTICS, 2004, 38 (03) : 243 - 272