Inexpensive and disposable copper mini-sensor modified with bismuth for lead and cadmium determination using square-wave anodic stripping voltammetry

被引:56
|
作者
Figueiredo-Filho, Luiz Carlos S. [1 ]
Janegitz, Bruno C. [1 ]
Fatibello-Filho, Orlando [1 ]
Marcolino-Junior, Luiz Humberto [2 ]
Banks, Craig E. [3 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, Ctr Ciencias Exatas & Tecnol, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Parana, Dept Quim, BR-81531990 Curitiba, Parana, Brazil
[3] Manchester Metropolitan Univ, Div Chem & Environm, Sch Chem & Environm, Fac Sci & Engn, Manchester M1 5GD, Lancs, England
基金
巴西圣保罗研究基金会;
关键词
CARBON-PASTE ELECTRODE; TRACE HEAVY-METALS; FILM ELECTRODES; ELECTROCHEMICAL DETERMINATION; WATER SAMPLES; MERCURY; COBALT; POTENTIALITIES; NICKEL; CD;
D O I
10.1039/c2ay26078f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication and evaluation of a disposable copper mini-sensor ex situ modified bismuth film for the sensing of lead(II) and cadmium(II) via square-wave anodic stripping voltammetry (SWASV) is presented. The sensor was ex situ modified with a bismuth film via electro-deposition through applying a potential of -0.18 V vs. Ag/AgCl (3.0 mol L-1 KCl) for 200 seconds in a 0.02 mol L-1 Bi(NO3)(3), 0.15 mol L-1 sodium citrate in 1.5 mol L-1 HCl solution. Under the optimal experimental conditions, the voltammetric response was linearly dependent on the analyte concentrations over the range from 1.3 x 10(-6) to 1.3 x 10(-5) mol L-1 and from 9.9 x 10(-7) to 1.2 x 10(-5) mol L-1 with a limit of detection of 8.3 x 10(-7) mol L-1 and 5.3 x 10(-7) mol L-1 for Pb(II) and Cd(II), respectively. The determination of both toxic metallic species was carried out in natural waters using the sensor obtaining results which are in close agreement with those obtained using Flame Atomic Absorption Spectrometry at a 95% confidence level.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 50 条
  • [41] Voltammetric Behavior of Testosterone on Bismuth Film Electrode: Highly Sensitive Determination in Pharmaceuticals and Human Urine by Square-Wave Adsorptive Stripping Voltammetry
    Levent, Abdulkadir
    Altun, Ahmet
    Tas, Suleyman
    Yardim, Yavuz
    Senturk, Zuhre
    ELECTROANALYSIS, 2015, 27 (05) : 1219 - 1228
  • [42] Determination of zinc in acacia honey by square wave stripping voltammetry with a bismuth-film-modified montmorillonite doped carbon paste electrode
    Meng, Jun
    Li, Fang
    Luo, Liqiang
    Wang, Xia
    Xiao, Min
    MONATSHEFTE FUR CHEMIE, 2014, 145 (01): : 161 - 166
  • [43] Square wave anodic stripping voltammetric determination of lead(II) using a glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes
    He, Xiuhui
    Chen, Li
    Xie, Xuan
    Su, Zhaohong
    Qin, Cong
    Liu, Ying
    Ma, Ming
    Yao, Shouzhuo
    Deng, Le
    Xie, Qingji
    Tian, Yun
    Qin, Dilan
    Luo, Yueping
    MICROCHIMICA ACTA, 2012, 176 (1-2) : 81 - 89
  • [44] Barium Hydrogen Phosphate Modified Carbon Paste Electrode for the Simultaneous Determination of Cadmium and Lead by Differential Pulse Anodic Stripping Voltammetry
    Sheela, T.
    Basavanna, S.
    Viswanatha, R.
    Kalachar, H. C. B.
    Naik, Y. Arthoba
    ELECTROANALYSIS, 2011, 23 (05) : 1150 - 1157
  • [45] Determination of Lead(II) and Cadmium(II) in Selected Commercially Available Water-Based Paints of Ethiopia by Anodic Stripping Voltammetry Using a Bismuth-Modified Glassy Carbon Electrode
    Muluneh, Enidale Yazie
    Mekonnen, Menbere Leul
    Debebe, Siraye Esubalew
    CHEMISTRYSELECT, 2023, 8 (30):
  • [46] Electrochemical determination of pterostilbene at a cathodically pretreated boron-doped diamond electrode using square-wave adsorptive anodic stripping voltammetry in cationic surfactant media
    Yigit, Aydin
    Yardim, Yavuz
    Zorer, Ozlem Selcuk
    Senturk, Zuhre
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 688 - 695
  • [47] Differential Pulse Anodic Stripping Voltammetry Determination of Lead(II) and Cadmium(II) with Multiwalled Carbon Nanotubes-Thiol Functionalized Chitosan Modified Bismuth Film Electrode
    Guo, Yan
    Ma, Yan
    Gao, Guizhi
    Li, Jun
    Xu, Jianqiang
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (01) : 113 - 118
  • [48] Ordered Mesoporous Carbon and Thiolated Polyaniline Modified Electrode for Simultaneous Determination of Cadmium(II) and Lead(II) by Anodic Stripping Voltammetry
    Tang, Lin
    Chen, Jun
    Zeng, Guangming
    Zhu, Yuan
    Zhang, Yi
    Zhou, Yaoyu
    Xie, Xia
    Yang, Guide
    Zhang, Sheng
    ELECTROANALYSIS, 2014, 26 (10) : 2283 - 2291
  • [49] Application of Square Wave Anodic Stripping Voltammetry for Determination of Traces of Ti(I) at Carbon Electrodes In Situ Modified with Bi Films
    Caldeira, Alexandra
    Gouveia-Caridade, Carla
    Pauliukaite, Rasa
    Brett, Christopher M. A.
    ELECTROANALYSIS, 2011, 23 (06) : 1301 - 1305
  • [50] Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1-Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode
    Segura, Rodrigo A.
    Pizarro, Jaime A.
    Oyarzun, Maria P.
    Castillo, Alejandra D.
    Diaz, Karina J.
    Placencio, Alan B.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (02): : 1707 - 1719