Inexpensive and disposable copper mini-sensor modified with bismuth for lead and cadmium determination using square-wave anodic stripping voltammetry

被引:56
|
作者
Figueiredo-Filho, Luiz Carlos S. [1 ]
Janegitz, Bruno C. [1 ]
Fatibello-Filho, Orlando [1 ]
Marcolino-Junior, Luiz Humberto [2 ]
Banks, Craig E. [3 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, Ctr Ciencias Exatas & Tecnol, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Parana, Dept Quim, BR-81531990 Curitiba, Parana, Brazil
[3] Manchester Metropolitan Univ, Div Chem & Environm, Sch Chem & Environm, Fac Sci & Engn, Manchester M1 5GD, Lancs, England
基金
巴西圣保罗研究基金会;
关键词
CARBON-PASTE ELECTRODE; TRACE HEAVY-METALS; FILM ELECTRODES; ELECTROCHEMICAL DETERMINATION; WATER SAMPLES; MERCURY; COBALT; POTENTIALITIES; NICKEL; CD;
D O I
10.1039/c2ay26078f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication and evaluation of a disposable copper mini-sensor ex situ modified bismuth film for the sensing of lead(II) and cadmium(II) via square-wave anodic stripping voltammetry (SWASV) is presented. The sensor was ex situ modified with a bismuth film via electro-deposition through applying a potential of -0.18 V vs. Ag/AgCl (3.0 mol L-1 KCl) for 200 seconds in a 0.02 mol L-1 Bi(NO3)(3), 0.15 mol L-1 sodium citrate in 1.5 mol L-1 HCl solution. Under the optimal experimental conditions, the voltammetric response was linearly dependent on the analyte concentrations over the range from 1.3 x 10(-6) to 1.3 x 10(-5) mol L-1 and from 9.9 x 10(-7) to 1.2 x 10(-5) mol L-1 with a limit of detection of 8.3 x 10(-7) mol L-1 and 5.3 x 10(-7) mol L-1 for Pb(II) and Cd(II), respectively. The determination of both toxic metallic species was carried out in natural waters using the sensor obtaining results which are in close agreement with those obtained using Flame Atomic Absorption Spectrometry at a 95% confidence level.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 50 条
  • [31] Carbon Paste Electrode Modified with Organofunctionalized Mesoporous Silica for Electrochemical Detection and Quantitative Determination of Cadmium (II) Using Square Wave Anodic Stripping Voltammetry
    Popa, Dana Elena
    Buleandra, Mihaela
    Mureseanu, Mihaela
    Ionica, Marcel
    Tanase, Ion Gh.
    REVISTA DE CHIMIE, 2010, 61 (02): : 162 - 167
  • [32] Determination of antibilharzial antimony compounds by direct current, differential pulse, square-wave and alternating current anodic stripping voltammetry
    Brodersen, K
    Hassan, HNA
    Hassouna, MEM
    Habib, IHI
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (06): : 745 - 748
  • [33] Determination of antibilharzial antimony compounds by direct current, differential pulse, square-wave and alternating current anodic stripping voltammetry
    K. Brodersen
    H. N. A. Hassan
    M. E. M. Hassouna
    I. H. I. Habib
    Fresenius' Journal of Analytical Chemistry, 1997, 358 : 745 - 748
  • [34] Sensitive determination of Cd(II) by square wave anodic stripping voltammetry with in situ bismuth-modified multiwalled carbon nanotubes doped carbon paste electrodes
    Luo, Jun Hua
    Jiao, Xiao Xia
    Li, Nian Bing
    Luo, Hong Qun
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 689 : 130 - 134
  • [35] A thermostated electrochemical flow cell with a coupled bismuth film electrode for square-wave anodic stripping voltammetric determination of cadmium(II) and lead(II) in natural, wastewater and tap water samples
    dos Santos, Vagner B.
    Fava, Elson L.
    de Miranda Curi, Newton S.
    Faria, Ronaldo C.
    Fatibello-Filho, Orlando
    TALANTA, 2014, 126 : 82 - 90
  • [36] A study of in situ plated tin-film electrodes for the determination of trace metals by means of square-wave anodic stripping voltammetry
    Czop, Edyta
    Economou, Anastasios
    Bobrowski, Andrzej
    ELECTROCHIMICA ACTA, 2011, 56 (05) : 2206 - 2212
  • [37] Determination of cadmium with a sequential injection lab-on-valve by anodic stripping voltammetry using a nafion coated bismuth film electrode
    Wang, Yang
    Liu, Zaiqing
    Yao, Guojun
    Zhu, Peihua
    Hu, Xiaoya
    Xu, Qin
    Yang, Chun
    TALANTA, 2010, 80 (05) : 1959 - 1963
  • [38] Mechanisms and kinetics of electrode processes at bismuth and antimony film and bare glassy carbon surfaces under square-wave anodic stripping voltammetry conditions
    Mirceski, Valentin
    Sebez, Bine
    Jancovska, Maja
    Ogorevc, Bozidar
    Hocevar, Samo B.
    ELECTROCHIMICA ACTA, 2013, 105 : 254 - 260
  • [39] Simultaneous determination of lead and cadmium in water samples using differential pulse anodic stripping voltammetry at platinum nanoflowers modified glassy electrode
    Lieu, Nguyen Thi
    Hoang, Cao Van
    Le, Pham Thi Tuyet
    Giang, Le Truong
    VIETNAM JOURNAL OF CHEMISTRY, 2019, 57 (03) : 379 - 383
  • [40] Detection of Cd2+ by Square Wave Anodic Stripping Voltammetry Using an Activated Bismuth-film Electrodes
    Yao Mei-Na
    Yang Xian-Jin
    Cui Zhen-Duo
    Zhu Sheng-Li
    Li Zhao-Yang
    Liang Yan-Qin
    JOURNAL OF INORGANIC MATERIALS, 2019, 34 (01) : 91 - 95