Inexpensive and disposable copper mini-sensor modified with bismuth for lead and cadmium determination using square-wave anodic stripping voltammetry

被引:56
|
作者
Figueiredo-Filho, Luiz Carlos S. [1 ]
Janegitz, Bruno C. [1 ]
Fatibello-Filho, Orlando [1 ]
Marcolino-Junior, Luiz Humberto [2 ]
Banks, Craig E. [3 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, Ctr Ciencias Exatas & Tecnol, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Parana, Dept Quim, BR-81531990 Curitiba, Parana, Brazil
[3] Manchester Metropolitan Univ, Div Chem & Environm, Sch Chem & Environm, Fac Sci & Engn, Manchester M1 5GD, Lancs, England
基金
巴西圣保罗研究基金会;
关键词
CARBON-PASTE ELECTRODE; TRACE HEAVY-METALS; FILM ELECTRODES; ELECTROCHEMICAL DETERMINATION; WATER SAMPLES; MERCURY; COBALT; POTENTIALITIES; NICKEL; CD;
D O I
10.1039/c2ay26078f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication and evaluation of a disposable copper mini-sensor ex situ modified bismuth film for the sensing of lead(II) and cadmium(II) via square-wave anodic stripping voltammetry (SWASV) is presented. The sensor was ex situ modified with a bismuth film via electro-deposition through applying a potential of -0.18 V vs. Ag/AgCl (3.0 mol L-1 KCl) for 200 seconds in a 0.02 mol L-1 Bi(NO3)(3), 0.15 mol L-1 sodium citrate in 1.5 mol L-1 HCl solution. Under the optimal experimental conditions, the voltammetric response was linearly dependent on the analyte concentrations over the range from 1.3 x 10(-6) to 1.3 x 10(-5) mol L-1 and from 9.9 x 10(-7) to 1.2 x 10(-5) mol L-1 with a limit of detection of 8.3 x 10(-7) mol L-1 and 5.3 x 10(-7) mol L-1 for Pb(II) and Cd(II), respectively. The determination of both toxic metallic species was carried out in natural waters using the sensor obtaining results which are in close agreement with those obtained using Flame Atomic Absorption Spectrometry at a 95% confidence level.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 50 条
  • [21] An electrochemical sensor for the determination of Cu(II) using a modified electrode with ferrocenyl crown ether compound by square wave anodic stripping voltammetry
    Flores, Erick
    Pizarro, Jaime
    Godoy, Fernando
    Segura, Rodrigo
    Gomez, Alejandra
    Agurto, Nicolas
    Sepulveda, Pamela
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 251 : 433 - 439
  • [22] SIMULTANEOUS ARSENIC (III) AND LEAD (II) DETECTION FROM AQUEOUS SOLUTION BY ANODIC STRIPPING SQUARE-WAVE VOLTAMMETRY
    Baciu, Anamaria
    Pop, Aniela
    Manea, Florica
    Schoonman, Joop
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2014, 13 (09): : 2317 - 2323
  • [23] In situ bismuth-film electrode for square-wave anodic stripping voltammetric determination of tin in biodiesel
    Frena, Morgana
    Campestrini, Iolana
    de Braga, Otoniel C.
    Spinelli, Almir
    ELECTROCHIMICA ACTA, 2011, 56 (12) : 4678 - 4684
  • [24] Investigation of Copper(II) Interference on the Anodic Stripping Voltammetry of Lead(II) and Cadmium(II) at Bismuth Film Electrode
    Yang, Die
    Wang, Liang
    Chen, Zuliang
    Megharaj, Mallavarapu
    Naidu, Ravi
    ELECTROANALYSIS, 2013, 25 (12) : 2637 - 2644
  • [25] SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY - DETERMINATION OF TRACE-METALS IN AQUEOUS EXTRACTS OF SOIL SAMPLES
    NOR, YM
    MCNEAL, BL
    CHEMICAL SPECIATION AND BIOAVAILABILITY, 1993, 5 (04): : 135 - 140
  • [26] Electrochemical Determination of Lead(II) in Environmental Waters Using a Sulfydryl Modified Covalent Organic Framework by Square Wave Anodic Stripping Voltammetry (SWASV)
    Wang, Rongyu
    Ji, Wenhua
    Huang, Luqi
    Guo, Lanping
    Wang, Xiao
    ANALYTICAL LETTERS, 2019, 52 (11) : 1757 - 1770
  • [27] Comparison of plain and indoline modified mercury film electrodes for determination of lead, cadmium and copper in urine samples by anodic stripping voltammetry
    Serap Titretir Duran
    A. Ersin Karagözler
    Polymer Bulletin, 2019, 76 : 2411 - 2425
  • [28] Determination of Trace Lead and Cadmium in Water Samples by Anodic Stripping Voltammetry with a NafionIonic Liquid-Coated Bismuth Film Electrode
    Yang, Die
    Wang, Liang
    Chen, Zuliang
    Megharaj, Mallavarapu
    Naidu, Ravi
    ELECTROANALYSIS, 2014, 26 (03) : 639 - 647
  • [29] Comparison of plain and indoline modified mercury film electrodes for determination of lead, cadmium and copper in urine samples by anodic stripping voltammetry
    Duran, Serap Titretir
    Karagozler, A. Ersin
    POLYMER BULLETIN, 2019, 76 (05) : 2411 - 2425
  • [30] Determination of copper ion by square wave anodic stripping voltammetry at antimony trioxide-modified carbon nanotube paste electrode
    Majidian, Mahsa
    Raoof, Jahan Bakhsh
    Hosseini, Sayed Reza
    Ojani, Reza
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (06) : 1263 - 1270