Inexpensive and disposable copper mini-sensor modified with bismuth for lead and cadmium determination using square-wave anodic stripping voltammetry

被引:56
作者
Figueiredo-Filho, Luiz Carlos S. [1 ]
Janegitz, Bruno C. [1 ]
Fatibello-Filho, Orlando [1 ]
Marcolino-Junior, Luiz Humberto [2 ]
Banks, Craig E. [3 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, Ctr Ciencias Exatas & Tecnol, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Parana, Dept Quim, BR-81531990 Curitiba, Parana, Brazil
[3] Manchester Metropolitan Univ, Div Chem & Environm, Sch Chem & Environm, Fac Sci & Engn, Manchester M1 5GD, Lancs, England
基金
巴西圣保罗研究基金会;
关键词
CARBON-PASTE ELECTRODE; TRACE HEAVY-METALS; FILM ELECTRODES; ELECTROCHEMICAL DETERMINATION; WATER SAMPLES; MERCURY; COBALT; POTENTIALITIES; NICKEL; CD;
D O I
10.1039/c2ay26078f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication and evaluation of a disposable copper mini-sensor ex situ modified bismuth film for the sensing of lead(II) and cadmium(II) via square-wave anodic stripping voltammetry (SWASV) is presented. The sensor was ex situ modified with a bismuth film via electro-deposition through applying a potential of -0.18 V vs. Ag/AgCl (3.0 mol L-1 KCl) for 200 seconds in a 0.02 mol L-1 Bi(NO3)(3), 0.15 mol L-1 sodium citrate in 1.5 mol L-1 HCl solution. Under the optimal experimental conditions, the voltammetric response was linearly dependent on the analyte concentrations over the range from 1.3 x 10(-6) to 1.3 x 10(-5) mol L-1 and from 9.9 x 10(-7) to 1.2 x 10(-5) mol L-1 with a limit of detection of 8.3 x 10(-7) mol L-1 and 5.3 x 10(-7) mol L-1 for Pb(II) and Cd(II), respectively. The determination of both toxic metallic species was carried out in natural waters using the sensor obtaining results which are in close agreement with those obtained using Flame Atomic Absorption Spectrometry at a 95% confidence level.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 47 条
[1]   Voltammetric detection of the herbicide metamitron at a bismuth film electrode in nondeaerated solution [J].
Arribas, Alberto Sanchez ;
Bermejo, Esperanza ;
Chicharro, Manuel ;
Zapardiel, Antonio .
ELECTROANALYSIS, 2006, 18 (23) :2331-2336
[2]   Polarography and voltammetry at mercury electrodes [J].
Barek, J ;
Fogg, AG ;
Muck, A ;
Zima, J .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2001, 31 (04) :291-309
[3]   Novel voltammetric methods for vanadium determination by exploitation of catalytic adsorptive vanadium-chloranilic acid-bromate system [J].
Bobrowski, A ;
Nowak, K ;
Zarebski, J .
ANALYTICA CHIMICA ACTA, 2005, 543 (1-2) :150-155
[4]   A study on the utility of bismuth-film electrodes for the determination of In(III) in the presence of Pb(II) and Cd(II) by square wave anodic stripping voltammetry [J].
Charalambous, A ;
Economou, A .
ANALYTICA CHIMICA ACTA, 2005, 547 (01) :53-58
[5]   Electrolytically fabricated nickel microrods on screen printed graphite electrodes: Electro-catalytic oxidation of alcohols [J].
Choudhry, Nadeem A. ;
Banks, Craig E. .
ANALYTICAL METHODS, 2011, 3 (01) :74-77
[6]   A screen-printed, amperometric biosensor array incorporated into a novel automated system for the simultaneous determination of organophosphate pesticides [J].
Crew, A. ;
Lonsdale, D. ;
Byrd, N. ;
Pittson, R. ;
Hart, J. P. .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (06) :2847-2851
[7]   Differential Pulse Voltammetric Determination of Paraquat Using a Bismuth-Film Electrode [J].
de Figueiredo-Filho, Luiz Carlos S. ;
dos Santos, Vagner B. ;
Janegitz, Bruno Campos ;
Guerreiro, Thiago Brito ;
Fatibello-Filho, Orlando ;
Faria, Ronald Censi ;
Marcolino-Junior, Luiz Humberto .
ELECTROANALYSIS, 2010, 22 (11) :1260-1266
[8]   Mercury film electrodes: developments, trends and potentialities for electroanalysis [J].
Economou, A ;
Fielden, PR .
ANALYST, 2003, 128 (03) :205-212
[9]   Bismuth-film electrodes: recent developments and potentialities for electroanalysis [J].
Economou, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (04) :334-340
[10]   Electrochemical determination of cadmium(II) at platinum electrode modified with kaolin by square wave voltammetry [J].
El Mhammedi, M. A. ;
Achak, M. ;
Hbid, M. ;
Bakasse, M. ;
Hbid, T. ;
Chtaini, A. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 170 (2-3) :590-594