DETERMINATIVE FACTORS OF BUILDING AIRTIGHTNESS

被引:0
|
作者
Kraus, Michal [1 ]
Senitkova, Ingrid Juhasova [1 ]
机构
[1] Inst Technol & Business Ceske Budejovice, Dept Civil Engn, Ceske Budejovice, Czech Republic
关键词
airtightness; air permeability; building envelope; energy performance;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
One of the basic principles of energy efficient buildings in accordance with sustainable development is perfectly airtight building envelope. Oversized heat losses through the building envelope leakage adversely affect the energy balance of buildings. The quality of airtight building envelope except for low energy consumption also minimizes the risk of damage to the structure associated with the spread of the heat and water vapor in the structure. The contribution provides diagnostic of the contemporary development in airtightness of buildings using by qualitative methods. The aim of contribution is to draw conclusions - dependences, definitions of weak and strong points of the process, their causes and consequences. It is necessary to pay attention to the determinative factors in whole process of building of airtightness. Carefully and thoroughly conducted analysis provides information and recommendations for improving the quality and the limitations of errors.
引用
收藏
页码:541 / 548
页数:8
相关论文
共 50 条
  • [21] Building airtightness measurement uncertainty due to steady stack effect
    Carrie, Francois Remi
    Olson, Collin
    Nelson, Gary
    ENERGY AND BUILDINGS, 2021, 237
  • [22] Some determinative factors for teachers' job motivation
    Cristina-Corina, Bentea
    CYPRUS INTERNATIONAL CONFERENCE ON EDUCATIONAL RESEARCH (CY-ICER-2012), 2012, 47 : 1638 - 1642
  • [23] Specifics of Building Envelope Air Leakage Problems and Airtightness Measurements
    Borodinecs, Anatolijs
    Nazarova, Jekaterina
    Zajacs, Aleksandrs
    Malyshev, Alexandr
    Pronin, Vladimir
    XV INTERNATIONAL CONFERENCE TOPICAL PROBLEMS OF ARCHITECTURE, CIVIL ENGINEERING, ENERGY EFFICIENCY AND ECOLOGY - 2016, 2016, 73
  • [24] Experimental analysis of building airtightness in traditional residential Portuguese buildings
    Salehi, Atefeh
    Torres, Isabel
    Ramos, Ana
    ENERGY AND BUILDINGS, 2017, 151 : 198 - 205
  • [25] IAQ and energy impacts of ventilation strategies and building envelope airtightness in a big box retail building
    Ng, Lisa C.
    Persily, Andrew K.
    Emmerich, Steven J.
    BUILDING AND ENVIRONMENT, 2015, 92 : 627 - 634
  • [26] DETERMINATIVE FACTORS OF THE CAPITAL STRUCTURE IN THE INTEGRATED COMPANY OF OIL
    Machado, Julio Henrique
    De Godoy, Carlos Roberto
    REVISTA CONTABILIDADE E CONTROLADORIA-RC C, 2013, 5 (01): : 82 - 98
  • [27] Impact of Building Airtightness on Heat Generator and Heat Emission Equipment Sizing
    Pecceu, Sebastien
    Van den Bossche, Paul
    IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,
  • [28] EFFECT OF SOME FACTORS ON THE TIME FOR INSPECTION FOR AIRTIGHTNESS WITH KEROSINE
    ROGAL, VF
    GRACH, PK
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1978, 14 (05): : 454 - 456
  • [29] A practical review of alternatives to the steady pressurisation method for determining building airtightness
    Zheng, Xiaofeng
    Cooper, Edward
    Gillott, Mark
    Wood, Christopher
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 132
  • [30] On the applicability of meta-analysis to evaluate airtightness performance of building components
    Prignon, Martin
    Altomonte, Sergio
    Ossio, Felipe
    Dawans, Arnaud
    Van Moeseke, Geoffrey
    BUILDING AND ENVIRONMENT, 2021, 194