EXPERIMENTAL INVESTIGATION ON THE PIPE LEAKAGE

被引:0
|
作者
Cai, Benan [1 ]
Zhang, Qi [1 ]
Weng, Yu [1 ]
Gu, Hongfang [1 ]
Wang, Haijun [1 ]
机构
[1] Xi An Jiao Tong Univ, Xian, Shaanxi, Peoples R China
来源
PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 4 | 2017年
关键词
FLASH EVAPORATION; TEMPERATURE;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Pipelines are widely used in many fields including power industry, petroleum system etc. Pipelines such as the surge line and main pipe are easily subjected to thermal stratification as a result of the non-uniform temperature distribution in the nuclear power plants. Furthermore, pipelines can suffer from thermal fatigue in virtue of long-term uneven stress distribution. When the surge line or main pipe subjected to thermal stratification and thermal fatigue keeps operating for long time, the pipe leakage may happen because of the existence of pipeline crack. The thermal pipeline crack leakage mainly appears in the region with stress concentration. As the pipe system is always covered with thermal insulation layer in the actual nuclear power plants, it is hard for workers to observe pipeline leak, which can have a bad effect on the normal operation. Since the temperature and humidity close to the pipe crack due to leakage can change compared to the normal operation, we can infer from the temperature and humidity changes that the pipe leakage occurs. Based on this idea, the temperature and humidity near the crack of the pipe need to be measured to detect the leakage fields. As the fluids with high pressure and high temperature flow in the pipe system in an actual nuclear power plant, the pipe leakage experiment was performed in the high pressure and high temperature condition. When the fluids with high temperature and pressure leak in the crack, the water will evaporate quickly, which means this process belongs to spray flash evaporation process. The temperature and humidity variations were monitored in the experiment with temperature and humidity probes which have the advantage of responding to the change of temperature and humidity sensitively. The data collection program was mainly written based on the LABVIEW platform. The collecting time step was set ls. As the measuring position and leakage flux are two key factors for the pipe leakage, the experiment was carried out with different measuring positions and leakage fluxes conditions. The experimental results showed that the leak flux had an important influence on the temperature and humidity near the pipe crack. The temperature and humidity started to change in a very short time with large leak flux. At the same time, the velocity of the temperature and humidity change was high with large leak flux. When the pipe leakage occurred in the location near the temperature and humidity probe, the temperature and humidity responded quickly and the velocity of temperature and humidity change was large. The experiment data can be used for the prediction of the pipe leakage in the nuclear power plants.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Experimental Investigation on Flash Evaporation Related to Pipe Leakage
    Cai, Benan
    Zhang, Qi
    Weng, Yu
    Gu, Hongfang
    Wang, Haijun
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2020, 6 (01):
  • [2] Experimental and numerical investigation on the mechanism of ground collapse induced by underground drainage pipe leakage
    Dai, Zili
    Peng, Linghao
    Qin, Shiwei
    ENVIRONMENTAL EARTH SCIENCES, 2024, 83 (01)
  • [3] Experimental investigation on pressure-leakage relation for high-density polyethylene pipe
    Sadr-Al-Sadati, Syed Ali
    Ghazizadeh, Mohammadreza Jalili
    URBAN WATER JOURNAL, 2019, 16 (04) : 289 - 298
  • [4] Experimental and numerical investigation on the mechanism of ground collapse induced by underground drainage pipe leakage
    Zili Dai
    Linghao Peng
    Shiwei Qin
    Environmental Earth Sciences, 2024, 83
  • [5] EXPERIMENTAL STUDIES ON LEAKAGE RATES AT PIPE FLANGES
    MICHEELY, A
    CHEMIE INGENIEUR TECHNIK, 1978, 50 (06) : 463 - 463
  • [6] Experimental Study of External Pipe Wall Erosion due to Water Pipe Leakage
    Zhang, Tuqiao
    Jiang, Shuhuai
    Wu, Fengxia
    Shao, Yu
    Chu, Shipeng
    JOURNAL OF PIPELINE SYSTEMS ENGINEERING AND PRACTICE, 2023, 14 (01)
  • [7] EXPERIMENTAL INVESTIGATION OF FLOW IN AN OSCILLATING PIPE
    CLAMEN, M
    MINTON, P
    JOURNAL OF FLUID MECHANICS, 1977, 81 (JUL13) : 421 - &
  • [8] Experimental Investigation on a Buried Leaking Pipe
    De Paola, F.
    Galdiero, E.
    Giugni, M.
    Papa, R.
    Urciuoli, G.
    16TH WATER DISTRIBUTION SYSTEM ANALYSIS CONFERENCE (WDSA2014): URBAN WATER HYDROINFORMATICS AND STRATEGIC PLANNING, 2014, 89 : 298 - 303
  • [9] GPR Survey for Pipe Leakage Detection: Experimental and Analytical Study
    Dong, L.
    Carnalla, S.
    Shinozuka, M.
    NONDESTRUCTIVE CHARACTERIZATION FOR COMPOSITE MATERIALS, AEROSPACE ENGINEERING, CIVIL INFRASTRUCTURE, AND HOMELAND SECURITY 2012, 2012, 8347
  • [10] Experimental investigation on leakage characteristics of finger seal
    Bai, Hua-Lei
    Ji, Hong-Hu
    Ji, Guo-Jian
    Cao, Guang-Zhou
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2009, 24 (03): : 532 - 536