Development of Diagnostic Reference Levels Using a Real-Time Radiation Dose Monitoring System at a Cardiovascular Center in Korea

被引:5
|
作者
Kim, Jungsu [1 ,3 ]
Seo, Deoknam [1 ,6 ]
Choi, Inseok [1 ]
Nam, Sora [1 ]
Yoon, Yongsu [8 ]
Kim, Hyunji [1 ,9 ]
Her, Jae [1 ]
Han, Seonggyu [1 ]
Kwon, Soonmu [2 ,7 ]
Park, Hunsik [4 ,5 ]
Yang, Dongheon [4 ,5 ]
Kim, Jungmin [1 ]
机构
[1] Korea Univ, Korea Univ Hlth Sci Univ, Coll Hlth Sci, Dept Radiol Sci, 219,Holim Bldg,Jeongneung 3 Dong, Seoul 136703, South Korea
[2] Catholic Univ Daegu, Coll Med Sci, Dept Radiol Sci, Daegu, South Korea
[3] Wonkwang Hlth Sci Univ, Dept Radiotechnol, Jeonbuk Do, South Korea
[4] Kyungpook Natl Univ, Sch Med, Dept Internal Med, Daegu, South Korea
[5] Kyungpook Natl Univ Hosp, Dept Heart & Brain Attack Ctr, Daegu, South Korea
[6] Korea Inst Radiol & Med Sci, Dept Diagnost Radiol, Seoul, South Korea
[7] Daegu Hlth Coll, Dept Radiol Technol, Daegu, South Korea
[8] Kyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Fukuoka 812, Japan
[9] Korea Ctr Dis Control & Prevent, Med Radiat TF Team, Ctr Dis Prevent, Chungcheongbuk Do, South Korea
关键词
DICOM MPPS; Radiation dose monitoring; Cardiovascular centre; Diagnostic reference levels; Order communication system; INTERVENTIONAL RADIOLOGY;
D O I
10.1007/s10278-015-9773-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital cardiovascular angiography accounts for a major portion of the radiation dose among the examinations performed at cardiovascular centres. However, dose-related information is neither monitored nor recorded systemically. This report concerns the construction of a radiation dose monitoring system based on digital imaging and communications in medicine (DICOM) data and its use at the cardiovascular centre of the University Hospitals in Korea. The dose information was analysed according to DICOM standards for a series of procedures, and the formulation of diagnostic reference levels (DRLs) at our cardiovascular centre represents the first of its kind in Korea. We determined a dose area product (DAP) DRL for coronary angiography of 75.6 Gy cm(2) and a fluoroscopic time DRL of 318.0 s. The DAP DRL for percutaneous transluminal coronary intervention was 213.3 Gy cm(2), and the DRL for fluoroscopic time was 1207.5 s.
引用
收藏
页码:684 / 694
页数:11
相关论文
共 50 条
  • [1] Development of Diagnostic Reference Levels Using a Real-Time Radiation Dose Monitoring System at a Cardiovascular Center in Korea
    Jungsu Kim
    Deoknam Seo
    Inseok Choi
    Sora Nam
    Yongsu Yoon
    Hyunji Kim
    Jae Her
    Seonggyu Han
    Soonmu Kwon
    Hunsik Park
    Dongheon Yang
    Jungmin Kim
    Journal of Digital Imaging, 2015, 28 : 684 - 694
  • [2] Development of a real-time monitoring system
    Marzi, H
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2002, 216 (06) : 933 - 937
  • [3] Real-time Radiation Monitoring System for FLASH
    Makowski, Dariusz
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2324 - 2329
  • [4] Network-based real-time radiation monitoring system in Synchrotron Radiation Research Center
    Sheu, RJ
    Wang, JP
    Chen, CR
    Liu, J
    Chang, FD
    Jiang, SH
    HEALTH PHYSICS, 2003, 85 (04): : 485 - 493
  • [5] Development of wireless communication system in real-time internal radiation dose measurement system using magnetic field
    Sato, Fumihiro
    Shinohe, Kohta
    Takura, Tetsuya
    Matsuki, Hidetoshi
    Yamada, Syogo
    Sato, Tadakuni
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (07)
  • [6] Development of Real-Time Drought Monitoring and Prediction System on Korea & East Asia Region
    Bae, Deg-Hyo
    Son, Kyung-Hwan
    Ahn, Joong-Bae
    Hong, Ja-Young
    Kim, Gwang-Soeb
    Chung, Jun-Seok
    Jung, Ui-Seok
    Kim, Jong-Khun
    ATMOSPHERE-KOREA, 2012, 22 (02): : 267 - 277
  • [7] Real-Time Patient Radiation Dose Monitoring System Used in a Large University Hospital
    Kim, Jungsu
    Yoon, Yongsu
    Seo, Deoknam
    Kwon, Soonmu
    Shim, Jina
    Kim, Jungmin
    JOURNAL OF DIGITAL IMAGING, 2016, 29 (05) : 627 - 634
  • [8] Real-Time Patient Radiation Dose Monitoring System Used in a Large University Hospital
    Jungsu Kim
    Yongsu Yoon
    Deoknam Seo
    Soonmu Kwon
    Jina Shim
    Jungmin Kim
    Journal of Digital Imaging, 2016, 29 : 627 - 634
  • [9] RADIATION MONITORING INSTRUMENTATION AND RADIATION-DOSE CALCULATIONS FOR REAL-TIME OFFSITE DOSE ASSESSMENTS
    LOCKRIDGE, JR
    HOWELL, RS
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 597 - 598
  • [10] Development of Data Acquisition System for Real-Time Monitoring Using a Smartphone
    Seretloa, Semakaleng
    Alatise, Mary
    5TH INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE, BIG DATA, COMPUTING AND DATA COMMUNICATION SYSTEMS (ICABCD2022), 2022,