Ultrasound does not provide reliable results for the measurement of the patellar tendon cross sectional area

被引:39
作者
Ekizos, Antonis [1 ]
Papatzika, Fyllis [1 ]
Charcharis, Georgios [1 ]
Bohm, Sebastian [1 ]
Mersmann, Falk [1 ]
Arampatzis, Adamantios [1 ]
机构
[1] Humboldt Univ, Dept Training & Movement Sci, D-10115 Berlin, Germany
关键词
Reproducibility; Repeatability; Accuracy; Tendon size; Tendon adaptation; ANTERIOR CRUCIATE LIGAMENT; HUMAN ACHILLES-TENDON; MECHANICAL-PROPERTIES; JUMPERS KNEE; IN-VIVO; VOLLEYBALL PLAYERS; CYCLIC STRAIN; HYPERTROPHY; TENDINITIS; STIFFNESS;
D O I
10.1016/j.jelekin.2013.08.004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Purpose: This study examined the reliability of patellar tendon cross sectional area (CSA) measurement using brightness mode ultrasonography. Methods: The patellar tendon CSA of fourteen participants was examined on two different days and at three different positions (proximal, median and distal). Five trials per day were conducted in each position, replacing the ultrasound probe on every trial. The images were examined by three different and equally experienced observers. We compared the mean of the five trials in each position to examine the day, observer and position effect. Further, Bland and Altman plots, root mean square (RMS) differences and intraclass correlation coefficients (ICC) were calculated. Results: There was a significant (p < 0.05) day, observer and position effect on the CSA, while the average ICC was 0.592. The Bland and Altman plots showed that differences between conditions or groups, should be in average lower than 37% or higher than 55% of the patellar tendon CSA to be important for clinical or intervention studies. Conclusion: Our findings show low reliability of the method, which resulted from the low clarity and unclear visibility of tissue boundaries in the ultrasound images. Therefore, the measurement of the CSA of the patellar tendon using ultrasound does not provide accurate and reliable results. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1278 / 1282
页数:5
相关论文
共 24 条
[1]   Adaptational responses of the human Achilles tendon by modulation of the applied cyclic strain magnitude [J].
Arampatzis, Adamantios ;
Karamanidis, Kiros ;
Albracht, Kirsten .
JOURNAL OF EXPERIMENTAL BIOLOGY, 2007, 210 (15) :2743-2753
[2]   Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain [J].
Arampatzis, Adamantios ;
Peper, Andreas ;
Bierbaum, Stefanie ;
Albracht, Kirsten .
JOURNAL OF BIOMECHANICS, 2010, 43 (16) :3073-3079
[3]   The anatomy of the patellar tendon [J].
Basso, O ;
Johnson, DP ;
Amis, AA .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2001, 9 (01) :2-5
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Passive knee joint range of motion is unrelated to the mechanical properties of the patellar tendon [J].
Bojsen-Moller, J. ;
Brogaard, K. ;
Have, M. J. ;
Stryger, H. P. ;
Kjaer, M. ;
Aagaard, P. ;
Magnusson, S. P. .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2007, 17 (04) :415-421
[6]   Influence of aging on the in vivo properties of human patellar tendon [J].
Carroll, C. C. ;
Dickinson, J. M. ;
Haus, J. M. ;
Lee, G. A. ;
Hollon, C. J. ;
Aagaard, P. ;
Magnusson, S. P. ;
Trappe, T. A. .
JOURNAL OF APPLIED PHYSIOLOGY, 2008, 105 (06) :1907-1915
[7]   Habitual loading results in tendon hypertrophy and increased stiffness of the human patellar tendon [J].
Couppe, C. ;
Kongsgaard, M. ;
Aagaard, P. ;
Hansen, P. ;
Bojsen-Moller, J. ;
Kjaer, M. ;
Magnusson, S. P. .
JOURNAL OF APPLIED PHYSIOLOGY, 2008, 105 (03) :805-810
[8]   EPIDEMIOLOGY OF JUMPERS KNEE [J].
FERRETTI, A .
SPORTS MEDICINE, 1986, 3 (04) :289-295
[9]   Mechanical properties of the human patellar tendon, in vivo [J].
Hansen, P ;
Bojsen-Moller, J ;
Aagaard, P ;
Kjaer, M ;
Magnusson, SP .
CLINICAL BIOMECHANICS, 2006, 21 (01) :54-58
[10]  
Helland C, 2013, BR J SPORTS MED