Fetal ECG Signal Extraction From Long-Term Abdominal Recordings Based on Adaptive QRS Removal and Joint Blind Source Separation

被引:7
|
作者
Wang, Lu [1 ,2 ]
Zhao, Chunhui [1 ,2 ]
Dong, Mianxiong [3 ]
Ota, Kaoru [3 ]
机构
[1] Harbin Engn Univ, Coll Informat & Commun Engn, Harbin 150001, Peoples R China
[2] Minist Ind & Informat Technol, Key Lab Adv Marine Commun & Informat Technol, Harbin 150001, Peoples R China
[3] Muroran Inst Technol, Dept Informat & Elect Engn, Muroran, Hokkaido 0508585, Japan
基金
中国国家自然科学基金;
关键词
Electrocardiography; Heart beat; Recording; Interference; Data mining; Blind source separation; Sensors; Adaptive maternal QRS removal (AQRSR); discriminator; fetal electrocardiography (ECG) signal; joint blind source separation (JBSS); tensor decomposition; CARDIOVASCULAR-DISEASE; HEART-RATE; DEVELOPING-WORLD; COMPONENTS; NETWORK;
D O I
10.1109/JSEN.2022.3206225
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Despite wearable electronic devices having enormous potential applications, the recording quality has not sufficiently met the requirements for fetal disease detection. In this article, we aim to propose a novel framework for fetal electrocardiography (ECG) extraction, where the hybrid approach mainly considers the combination of a novel adaptive maternal QRS removal (AQRSR) algorithm and a tensor-based joint blind source separation (JBSS) approach. To adapt to the dynamic change of the ECG signal and suppress the powerful maternal heartbeat, AQRSR is explored with an adaptive template, which is generated by a model consisting of a generator, discriminator, and transformer. By replacing the oldest segmentation with the newest cycle, the approach is capable of quickly adapting to the estimated output to match the new input. In addition, due to the significant crossover between the target signal and the noise, even if the maternal ECG removal processing is implemented, the residual signal inevitably contains fetal ECG, part of maternal ECG, and noise. As a consequence of this, a novel JBSS that incorporates tensor decomposition is formulated to separate fetal heartbeat from long-term recordings contaminated with maternal movements noise and heartbeat interference. By dividing the collected data into multiple segments, this method can extract fetal ECG signals by exploiting the signals that are not only statistically independent within each segment but can be dependent on different segments. Experimental results show that even if the recorded signals are contaminated by the noise, the proposed framework has comparable better performance on fetal ECG extraction.
引用
收藏
页码:20718 / 20729
页数:12
相关论文
共 25 条
  • [1] Fetal ECG Extraction From Abdominal Recordings using Array Signal Processing
    Haghpanahi, Masoumeh
    Borkholder, David A.
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 173 - 176
  • [2] Spatial Filtering and Adaptive Rule Based Fetal Heart Rate Extraction from Abdominal Fetal ECG Recordings
    Xu-Wilson, Minnan
    Carlson, Eric
    Cheng, Limei
    Vairavan, Srinivasan
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 197 - 200
  • [3] Fetal QRS extraction from abdominal recordings via model-based signal processing and intelligent signal merging
    Haghpanahi, Masoumeh
    Borkholder, David A.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (08) : 1591 - 1605
  • [4] A new method for the extraction of fetal ECG from the dependent abdominal signals using blind source separation and adaptive noise cancellation techniques
    Ghazdali, Abdelghani
    Hakim, Abdelilah
    Laghrib, Amine
    Mamouni, Nezha
    Raghay, Said
    THEORETICAL BIOLOGY AND MEDICAL MODELLING, 2015, 12
  • [5] Fetal ECG Extraction and QRS Detection Using Advanced Adaptive Filtering-Based Signal Decomposition and Peak Threshold Technique from Abdominal ECG Signals
    Jebastine, J.
    CIRCUITS SYSTEMS AND SIGNAL PROCESSING, 2023, 42 (10) : 6058 - 6088
  • [6] Fetal ECG Extraction and QRS Detection Using Advanced Adaptive Filtering-Based Signal Decomposition and Peak Threshold Technique from Abdominal ECG Signals
    J. Jebastine
    Circuits, Systems, and Signal Processing, 2023, 42 : 6058 - 6088
  • [7] Extraction of Fetal ECG Signal with Ectopic Beats using Blind Source Separation Based Null Space Approach
    Taha, Luay Yassin
    Abdel-Raheem, Esam
    2020 IEEE CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2020,
  • [8] Elicitation of fetal ECG from abdominal recordings using Blind Source Separation techniques and Robust Set Membership Affine Projection algorithm for signal quality enhancement
    Diwan S.
    Sahu M.
    Bhateja V.
    Computers in Biology and Medicine, 2024, 178
  • [9] A robust physiology-based source separation method for QRS detection in low amplitude fetal ECG recordings
    Vullings, R.
    Peters, C. H. L.
    Hermans, M. J. M.
    Wijn, P. F. F.
    Oei, S. G.
    Bergmans, J. W. M.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (07) : 935 - 951
  • [10] Fetal ECG Extraction from Abdominal ECG Using RLS based Adaptive Algorithms
    Kahankova, Radana
    Martinek, Radek
    Bilik, Petr
    2017 18TH INTERNATIONAL CARPATHIAN CONTROL CONFERENCE (ICCC), 2017, : 337 - 342